Sharp GS-XP9FGR Operation Manual page 17

Table of Contents

Advertisement

TIMER ON
MODE
1h
FAN
SWING
SET/C
COMBINED USE OF ON AND OFF TIMERS
You can use the ON and OFF timers in combination.
NOTES:
• You cannot programme the ON-TIMER and OFF-TIMER to operate the unit at different tempera-
tures or other settings.
• Either timer can be programmed to activate prior the other.
1
Press the TIMER ON (
2
The TIMER ON indicator will blink; press the TIME
ADVANCE or REVERSE buttons to set the de-
sired time. (The time can be set in 10-minute
increments.)
3
Point the remote control at the signal receiver
window on the unit and press the TIMER SET
(SET/C) button.
• The orange TIMER lamp (
• The unit will generate a beep when it receives the
signal.
4
Select the operation condition.
1
NOTE:
• The unit will turn on prior to the set timer to allow the
2
room to reach the desired temperature by the pro-
grammed time. (Awaking function)
3
Example:
To stop operation at 11:00 p.m. and resume operation
(With the same mode and temperature settings) to turn
on the unit by 7:00 a.m.
1
Set the TIMER OFF to 11:00 p.m. during operation.
2
Set the TIMER ON to 7:00 a.m.
The arrow (
and the TIMER OFF indicator shows which timer will
activate first.
E-15
) button.
) on the unit will light.
or
) between the TIMER ON indicator

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs-xp12fgrGs-xp18fgrGs-xpm9fgrGs-xpm12fgrGs-xpm18fgr

Table of Contents