WARNING:
NEVER ignore an automatic shutoff event. IF AUTOMATIC
SHUTOFF OCCURS – YOU MUST leave the area imme-
diately and relocate to an open outdoor area. Ventilate
the area thoroughly before occupying again. Ensure the
generator is located in an open, outdoor area. Always
point exhaust away from occupied structures. Never
run the generator in enclosed areas (e.g. not in a house
or garage). Failure to follow these instructions can lead
to carbon monoxide (CO) poisoning which can result in
death or serious personal injury.
WARNING:
If this generator will be used only with cord and plug-
connected equipment, National Electric Code does not
require that the unit be grounded. However, other methods
of using the generator may require grounding to reduce the
risk of shock or electrocution. Consult a qualified electrician,
electrical inspector, or local agency having jurisdiction for
local codes or ordinances to find out if grounding is needed
in your situation before using the generator.
WARNING:
Do not allow familiarity with this product to make you
careless. Remember that a careless fraction of a second
is sufficient to inflict serious injury.
WARNING:
Do not use any attachments or accessories not
recommended by the manufacturer of this product. The
use of attachments or accessories not recommended
can result in serious personal injury.
NOTICE:
This product is equipped with a spark arrestor that has
been evaluated by the USDA Forest Service; however,
product users must comply with Federal, State, and local
fire prevention regulations. Check with appropriate au-
thorities. Contact customer service or a qualified service
center to purchase a replacement spark arrestor.
NOTICE:
Before each use, inspect the entire product for damaged,
missing, or loose parts such as screws, nuts, bolts,
caps, etc. Tighten securely all fasteners and caps and
do not operate this product until all missing or damaged
parts are replaced. Please contact customer service or
a qualified service center for assistance.
OPERATION
APPLICATIONS
This generator is designed to supply electrical power for
operating compatible electrical lighting, appliances, tools,
and motor loads.
BEFORE OPERATING THE UNIT
 Only use OUTSIDE and at least 20 feet away from win-
dows, doors, and vents as recommended by the U.S
Department of Health and Human Services Centers for
Disease Control and Prevention. Your specific home and/
or wind conditions may require additional distance.
 NEVER use inside a home or garage, EVEN IF doors and
windows are open.
 Always position the generator on a flat firm surface.
SPECIAL REQUIREMENTS:
There may be General or State Occupational Safety and
Health Administration (OSHA) regulations, local codes or
ordinances that apply to the intended use of the generator.
Please consult a qualified electrician, electrical inspector, or
the local agency having jurisdiction:
 In some areas, generators are required to be registered
with local utility companies.
 If the generator is used at a construction site, there may
be additional regulations which must be observed.
RAISING AND LOWERING THE HANDLE
See Figure 8.
 To raise the handle (for moving the generator): pull the
handle release knob out, raise the handle, then release
the knob so it snaps into the locking position. Insert the
handle lock pin to secure the handle in place.
 To lower the handle (for storing or transporting the
generator): remove the handle lock pin, then pull the
handle release knob out and lower the handle to the down
position.
Never use the handle to lift the generator. The handle should
only be used for moving the unit by rolling it on its wheels.
CHECKING/ADDING LUBRICANT
See Figure 9.
NOTICE:
Attempting to start the engine before it has been properly
filled with lubricant will result in equipment failure.
NOTE: If a separate engine manual is provided for this
product, please follow the instructions provided in the
engine manual instead of the information listed below.
Engine lubricant has a major influence on engine performance
and service life. For general, all-temperature use, SAE 10W-
30 full synthetic is recommended. Always use a 4-stroke
motor lubricant that meets or exceeds the requirements for
API service classification SJ.
Page 13 — English