Maintenance - RIDGID R150FSF Operator's Manual

Finish stapler
Table of Contents

Advertisement

Available languages

Available languages

OPERATION
CLEARING A JAMMED FASTENER
See Figure 9, page 15.
WARNING:
Disconnect the tool from the air supply before
clearing a jammed fastener. Failure to do so could
result in serious personal injury.
If a fastener becomes jammed in the tool, disconnect the
air hose and keep the tool pointed away from you while
clearing the jam.

MAINTENANCE

WARNING:
When servicing use only identical RIDGID
replacement parts. Use of any other parts may
create a hazard or cause product damage.
WARNING:
Always wear eye protection with side shields
marked to comply with ANSI Z87.1. Failure to do
so could result in objects being thrown into your
eyes resulting in possible serious injury.
WARNING:
Disconnect the tool from the air supply before
performing maintenance. Failure to do so could
result in serious personal injury.
GENERAL MAINTENANCE
Avoid using solvents when cleaning plastic parts. Most
plastics are susceptible to damage from various types of
commercial solvents and may be damaged by their use. Use
clean cloths to remove dirt, dust, oil, grease, etc.
WARNING:
Do not at any time let brake fluids, gasoline,
petroleum-based products, penetrating oils, etc.,
come in contact with plastic parts. Chemicals can
damage, weaken or destroy plastic which may
result in serious personal injury.
 Open the magazine and remove the fasteners from the
tool.
 Insert a flat blade screwdriver into the driving mechanism
and push the driver mechanism back, freeing the fastener
jam.
 Remove the bent fastener.
 Reconnect the tool to the air supply.
 Reinsert fasteners and close the magazine.
LUBRICATION
The cylinder, o-ring, and piston ring in this tool are lubricated
with a sufficient amount of high grade lubricant for the life
of the unit under normal operating conditions. Therefore, no
further lubrication is required.
COLD WEATHER OPERATION
For cold weather operation, near and below freezing, the
moisture in the air line may freeze and prevent tool operation.
We recommend the use of air tool lubricant or permanent
antifreeze (ethylene glycol) as a cold weather lubricant.
NOTICE:
Do not store tools in a cold weather environment
to prevent frost or ice formation on the tools'
operating valves and mechanisms that could cause
tool failure.
NOTE: Some commercial air line drying liquids are harmful
to O-rings and seals. Do not use these low temperature air
dryers without checking compatibility.
AIR SUPPLY PRESSURE AND VOLUME
Air volume is as important as air pressure. The air volume
supplied to the tool may be inadequate because of undersize
fittings and hoses, or from the effects of dirt and water in the
system. Restricted air flow will prevent the tool from receiving
an adequate volume of air, even though the pressure reading
is high. The results will be a slow operation or reduced
driving power. Before evaluating tool problems for these
symptoms, trace the air supply from the tool to the supply
source for restrictive connectors, low points containing
water and anything else that would prevent full volume flow
of air to the tool.
10 – English