IMPORTANT INSTRUCTIONS -
Models: ES80D, ES130D, ES80DG,
ES130DG, ES80DH, ES130DH, ES130D2
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
electric shock and injury to person, including the following:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA)
and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6728039 Rev. B 3-13
OPERATING MANUAL
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
f) This unit must be grounded.
g) To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
h) Suitable for use with electronic speed control device.
CAUTION:
USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND
VAPORS.
WARNING:
i) Read all instructions before installing or using exhaust fan.
www.airkinglimited.com
Exhaust Fan
FOR GENERAL VENTILATING USE ONLY. DO NOT
DO NOT USE IN KITCHENS.
1 of 12

Advertisement

Table of Contents
loading

Summary of Contents for Air King ES130D2

  • Page 1 OPERATING MANUAL Models: ES80D, ES130D, ES80DG, Exhaust Fan ES130DG, ES80DH, ES130DH, ES130D2 READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2: Installation Instructions

    INSTALLATION INSTRUCTIONS CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. SECTION 1 Preparing the Exhaust Fan Unpack fan from the carton and confirm that all pieces are present. In addition Joist to the exhaust fan you should have: 1 - Grill Figure 3 1 - Damper Assembly (attached)
  • Page 3 Supply from house Neutral (White) Ground (Green or Bare) Plug Tabs Black (Black) Hex Nuts Yellow Switch Figure 6 Yellow Figure 9 NOTE: If the fan motor plug is connected to the fan housing receptacle, unplug so the blower assembly can be completely removed. NOTE: The fan’s receptacle wires might need to be pulled outside compartment for connection.
  • Page 4 2b. MOTION SENSING MODELS: Plug the fan’s 2 pin and 3 pin quick connect motor cords into the receptacles located on the side of the wire compartment. Plug the 3 pin quick connect cord from the motion sensor on the grill into the receptacle coming out of the top of the wire compartment.
  • Page 5: Troubleshooting Guide

    WHAT AIR KING WILL DO: During the warranty period, Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole product with the same or comparable model.
  • Page 6: Replacement Parts Diagram

    Wire Compartment Assembly - ES130DG 5S1239019 Mounting Channel 5S1239021 Grill Assembly 5S1239115 Blower Assembly 5S2239008 Specific to Models ES80DH, ES130DH Specific to Models ES80D, ES130D, ES130D2 Qty. Description Replacement Part # Grill 5S1202048 Qty. Description Replacement Part # Grill 5S1202048...
  • Page 7: Ventilateur D'évacuation

    INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Modéles : ES80D, ES130D, ES80DG, Ventilateur d’Évacuation ES130DG, ES80DH, ES130DH, ES130D2 LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8: Instructions D'installation

    INSTRUCTIONS D’INSTALLATION AVERTISSEMENT : VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION. SECTION 1 Préparation du Ventilateur d’évacuation Sortir le ventilateur de sa boite et confirmer que toutes les pièces sont Solive présentes. En plus du ventilateur d’évacuation vous devriez avoir : 1 - Grille Figure 3 1 - Ensemble de clapet (attaché)
  • Page 9 Alimentation provenant de la résidence Blanc Raccord Fil de Masse Onglets Écrou Jaune Hexagonal Ventilateur Fil Chaud (Noir) Figure 6 Jaune REMARQUE : Si le raccord du moteur de ventilateur est raccordé au réceptacle du Figure 9 Commutateur châssis, le débrancher afin que l’assemblage de la soufflante soit complètement enlevé. REMARQUE : Les fils du réceptacle du ventilateur pourraient nécessiter d’être tirés Couvercle du à...
  • Page 10 2b. MODÈLES DÉTECTION DE MOUVEMENT: Branchez les cordons du moteur du une vitesse) ou au connecteur de la partie supérieure du compartiment de fil ventilateur à 2 et 3 broches de connexion rapide dans les connecteurs situés sur (modèles à deux vitesses). Ce cordon ne s’adapte que d’une seule façon dans le côté...
  • Page 11: Guide De Dépannage

    Cette garantie ne couvre pas les coûts d’expédition pour le retour des produits à Air King pour la réparation ou le remplacement. Air King payera les frais d’expédition de retour de Air King après les réparations ou le remplacement de garantie.
  • Page 12 5S1239019 Canal de montage 5S1239021 Assemblée de Grille 5S1239115 Assemblée de la Soufflante 5S2239008 Particularités des modèles ES80DH, ES130DH Particularités des modèles ES80D, ES130D, ES130D2 # de pièce Qté. Description de remplacement # de pièce Qté. Description de remplacement Grille...

This manual is also suitable for:

Es130dEs80dgEs130dgEs80dhEs130dhEs80d

Table of Contents