IMPORTANT INSTRUCTIONS -
Models: ES80SG, ES130SG,
ES80DG, ES130DG
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
electric shock and injury to person, including the following:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If
you have questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA)
and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
A210572215 Rev. D 8-12
OPERATING MANUAL
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
f) This unit must be grounded.
g) To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
h) Suitable for use with electronic speed control device.
CAUTION:
USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND
VAPORS.
WARNING:
i) Read all instructions before installing or using exhaust fan.
www.airkinglimited.com
Exhaust Fan
FOR GENERAL VENTILATING USE ONLY. DO NOT
DO NOT USE IN KITCHENS.
1 of 12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ES130DG and is the answer not in the manual?

Questions and answers

Summary of Contents for Air King ES130DG

  • Page 1: General Safety Information

    IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: ES80SG, ES130SG, Exhaust Fan ES80DG, ES130DG READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2: Installation Instructions

    INSTALLATION INSTRUCTIONS CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. SECTION 1 Preparing the Exhaust Fan Unpack fan from the carton and confirm that all pieces are present. In Joist addition to the exhaust fan you should have: 1 - Grill Figure 3 1 - Damper Assembly (attached)
  • Page 3: Completing The Installation

    1b. Internal Wire Compartment: Using a 7/16" socket, remove the two hex Supply from nuts holding the blower assembly in place. Lift up on the assembly and slide it out of the tabs on the housing (Figure 6). Remove the house wire compartment cover screw and place the cover in a secure place Hot (Black)
  • Page 4 From Sensor From Motor From Motor Figure 14 Figure 11 2b. TWO SPEED UNITS (models ES80DG and ES130DG): Plug the fan’s 2 Restore power and test your installation. pin and 3 pin quick connect motor cords into the receptacles located on the side of the wire compartment.
  • Page 5: Troubleshooting Guide

    WHAT AIR KING WILL DO: During the warranty period, Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole product with the same or comparable model.
  • Page 6: Replacement Parts Diagram

    REPLACEMENT PARTS DIAGRAM SINGLE SPEED UNITS 15-16 DUAL SPEED UNITS Qty. Description Replacement Part # Qty. Description Replacement Part # Fan Housing 5S1239009 18 ga Ground Wire 5S1999111 Mounting Rails 5S1299002 Wire Compartment Assembly - ES80SG 5S1239016 Blower Assembly 5S2239008 Wire Compartment Assembly - ES130SG 5S1239017 6”...
  • Page 7: Ventilateur D'évacuation

    INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Modéles : ES80SG, ES130SG, Ventilateur d’Évacuation ES80DG, ES130DG LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8: Instructions D'installation

    INSTRUCTIONS D’INSTALLATION AVERTISSEMENT : VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION. SECTION 1 Préparation du Ventilateur d’évacuation Solive Sortir le ventilateur de sa boite et confirmer que toutes les pièces sont présentes. En plus du ventilateur d’évacuation vous devriez avoir : Figure 3 1 - Grille 1 - Ensemble de clapet (attaché)
  • Page 9 1b. Compartiment de Câblage Intérieur: Enlever les trois vis retenant en Alimentation provenant de place l’assemblage de la soufflante et soulever pour sortir l’assemblage hors du châssis (Figure 6). Enlever la vis du couvercle du compartiment la résidence à câblage et mettre ce couvercle dans un endroit fiable (Figure 7). Fil de Masse Blanc Raccord...
  • Page 10 Du capteur de mouvement Du moteur Du moteur Figure 14 Figure 11 2b. UNITÉS DE DEUX VITESSES (modèles ES80DG et ES130DG) : Branchez Restaurer l’alimentation et tester votre installation. les cordons du moteur du ventilateur à 2 et 3 broches de connexion rapide dans les connecteurs situés sur le côté...
  • Page 11: Utilisation Et Entretien

    Cette garantie ne couvre pas les coûts d’expédition pour le retour des produits à Air King pour la réparation ou le remplacement. Air King payera les frais d’expédition de retour de Air King après les réparations ou le remplacement de garantie.
  • Page 12 DIAGRAMME DES PIÈCES DE REMPLACEMENT UNITÉS À UNE VITESSE 15-16 UNITÉS À DEUX VITESSES # de pièce # de pièce Qté. Description de remplacement Qté. Description de remplacement Cabinet du ventilateur 5S1239009 Fil de mise à la terre de calibre # 18 5S1999111 Traverses de Montage 5S1299002...

This manual is also suitable for:

Es80sgEs80dgEs130sg

Table of Contents