IMPORTANT INSTRUCTIONS -
ESBGH,
Series
ESVDGH
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
electric shock and injury to person, including the following:
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK
AND INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK
AND INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA)
and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6728055 Rev. B 5-14
OPERATING MANUAL
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
f) This unit must be grounded.
g) To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
h) Suitable for use with electronic speed control device.
CAUTION:
USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND
VAPORS.
WARNING:
i) Read all instructions before installing or using exhaust fan.
www.airkinglimited.com
Exhaust Fan
FOR GENERAL VENTILATING USE ONLY. DO NOT
DO NOT USE IN KITCHENS.
1 of 12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ESBGH Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Air King ESBGH Series

  • Page 1: General Safety Information

    IMPORTANT INSTRUCTIONS - OPERATING MANUAL ESBGH, Series Exhaust Fan ESVDGH READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2: Installation Instructions

    SECTION 4 INSTALLATION INSTRUCTIONS Ducting CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE CAUTION: STARTING INSTALLATION. ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES. SECTION 1 Connect the ducting to the fan’s duct collar (Figure 4). Secure in place using tape Preparing the Exhaust Fan or screw clamp.
  • Page 3: Adjustment Knobs

    Plug the fan’s 2 pin and 3 pin quick connect motor cords into the corresponding receptacle located on the wire compartment cover. Connect the two pin connector from the humidistat compartment to the two pin connector from the side of the wire compartment cover.
  • Page 4 SECTION 8 Setting the Humidistat This fan is equipped with a humidity sensor that automatically turns the fan on when humidity is above set point and off when humidity is at or below set point. If the fan is operating too long or not enough, first check to see the humidity sensor set point.
  • Page 5: Troubleshooting Guide

    WHAT AIR KING WILL DO: During the warranty period, Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole product with the same or comparable model.
  • Page 6: Replacement Parts Diagram

    REPLACEMENT PARTS DIAGRAM All Models Specific to Models ESB80SGH, ESB130SGH Qty. Description Replacement Part # Qty. Description Replacement Part # Mounting Rails 5S1299002 Wire Compartment Assembly - ESB80SGH 5S1239822 6” Metal Collar Assembly 5S5299100 Wire Compartment Assembly - ESB130SGH 5S1239823 Grill Springs 5S1202046 Specific to Models ESB80DGH, ESB130DGH...
  • Page 7: Ventilateur D'évacuation

    INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Série ESBGH, ESVDGH Ventilateur d’Évacuation LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8 SECTION 4 INSTRUCTIONS D’INSTALLATION Conduits ATTENTION : VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU ATTENTION : PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION. TOUS LES CONDUITS DOIVENT ÊTRE CONFORMES AUX CODES DU BÂTIMENT LOCAUX ET NATIONAUX. SECTION 1 Raccorder le conduit au collet de conduit du ventilateur (Figure 4). Fixer en place à Préparation du Ventilateur d’évacuation l’aide de ruban ou de serre-joint.
  • Page 9 Si l’assemblage de la soufflante du ventilateur a été enlevé durant le processus de raccordement, réinstaller la soufflante en inversant les instructions à l’étape 1b de la Section 5 Câblage. Couvercle du Branchez les câbles à 2 broches du ventilateur et les câbles à 3 broches de connexion Compartiment de rapide du moteur dans la prise correspondante située sur le couvercle du compartiment de fil.
  • Page 10 SECTION 8 Installez la grille en pressant le ressort le plus loin possible du détecteur de mouvement et installez-le dans la fente la plus éloignée du compartiment de fil sur le logement du Réglage de l’humidostat ventilateur. Attachez le cordon de 3 broches à connexion rapide à partir du capteur de mouvement sur le gril soit au câblage installé...
  • Page 11: Guide De Dépannage

    Cette garantie ne couvre pas les coûts d’expédition pour le retour des produits à Air King pour la réparation ou le remplacement. Air King payera les frais d’expédition de retour de Air King après les réparations ou le remplacement de garantie.
  • Page 12 DIAGRAMME DES PIÈCES DE REMPLACEMENT Tous les modèles Particularités des modèles ESB80SGH, ESB130SGH # de pièce # de pièce Qté. Description de remplacement Qté. Description de remplacement Traverses de Montage 5S1299002 Assemblée du compartiment du fil - ESB80SGH 5S1239822 Assemblée de collier en métal de 6 po 5S5299100 Assemblée du compartiment du fil - ESB130SGH 5S1239823...

This manual is also suitable for:

Esvdgh series

Table of Contents