P/N 900923-00 REV. A 09/2019
Ce manuel est disponible en francais, simplement en
faire la demande. Numéro de la pièce 900923-03.
P900923-00
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit
is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Installation and Operation Instructions
Aries™ 33 Series Direct-Vent Fireplaces
Models
Traditional
C
US
Report No. F13-094
Contemporary
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
Aries33TMN
Aries33TEN
Aries33TMP
Aries33TEP
AriesCD33TMN
AriesCD33TEN
AriesCD33TMP
AriesCD33TEP
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié
ou par le fournisseur de gaz.
Aries33RMN
Aries33REN
Aries33RMP
Aries33REP
AriesCD33REN
AriesCD33RMN
AriesCD33RMP
AriesCD33REP

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Aries 33 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Astria Fireplaces Aries 33 Series

  • Page 1 Installation and Operation Instructions Aries™ 33 Series Direct-Vent Fireplaces P/N 900923-00 REV. A 09/2019 Models Ce manuel est disponible en francais, simplement en Traditional faire la demande. Numéro de la pièce 900923-03. Aries33TMN Aries33TEN Aries33RMN Aries33REN Aries33TMP Aries33TEP Aries33RMP Aries33REP Report No.
  • Page 2: General Information

    Innovative Hearth Products General Information Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 SAFETY AND YOUR FIREPLACE See attached color flyer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is pro- vided with this appliance and must be installed for the protection of children and other at-risk individuals.
  • Page 3 Innovative Hearth Products General Information Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 La sécurité et Safety and Your Seguridad y su votre foyer Fireplace chimenea All parts of your ¡Todas las partes de la Toutes les parties de votre IHP fireplace get chimenea IHP se ponen foyer IHP deviennent EXTREMELY HOT!
  • Page 4: Table Of Contents

    Innovative Hearth Products General Information Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Traditional Fireplace Contemporary Fireplace THANK YOU FOR YOUR PURCHASE. WE APPRECIATE YOUR BUSINESS! Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information.
  • Page 5: Important Safety Information

    Innovative Hearth Products General Information Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 IMPORTANT SAFETY INFORMATION Important Safety Informa- L’information de sûreté Información importante de tion importante seguridad 1. WARNING: Do not operate appliance 1. AVERTISSEMENT. Ne pas utiliser l’appareil 1. ADVERTENCIA: No opere el artefacto con el with the glass front removed, cracked si le panneau frontal en verre n’est pas en frente de vidrio quitado, agrietado o roto.
  • Page 6: Fireplace Installation, Operation, And Maintenance Notices

    Innovative Hearth Products General Information Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 APPLIANCE INSTALLATION, SERVICE, AND MAINTENANCE NOTICES WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
  • Page 7 Innovative Hearth Products General Information Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 APPLIANCE OPERATION NOTICES These fireplaces are vented gas appliances. Do not burn wood or other material in these appliances. These appliances are designed to operate on natural gas or propane gas only. The use of other fuels or combinations of fuels will degrade the performance of this system and may be dangerous.
  • Page 8: Packaging List

    Innovative Hearth Products General Information Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 INSTALLATION PACKAGING LIST All models include The assembled vented gas fireplace heater is packaged with: • Literature Kit (envelope in bottom compartment containing Installation and Operation Instructions (this manual), Hot Glass Safety Flyer, and Safety-In-Operation Warning Labels) •...
  • Page 9: Gas Pressure

    Innovative Hearth Products General Information Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 BTU Input Table 1 - Input Rate, Gas Valves Input Rate (BTU/HR) Models Natural Gas Propane Gas 33” Models 12,000 10,000 Table 2 - Thermal Efficiency (%) Millivolt Electronic Model AFUE * P4 ** AFUE *...
  • Page 10: Requirements For The Commonwealth Of Massachusetts

    Innovative Hearth Products General Information Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Orifice Sizes—Sea Level to High Altitude These fireplaces are tested and approved for installation at elevations of 0–4500 ft (0–1372 m) above sea level using the standard burner orifice sizes (Table 5) . For elevations above 4500 ft, contact your gas supplier or qualified service technician.
  • Page 11: Manufactured Home Requirements

    Innovative Hearth Products General Information Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 MANUFACTURED HOME REQUIREMENTS This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. Cet appareil peut être installé dans une maison préfabriquée (mobile) déjà installée à demeure si les règlements locaux le permettent.
  • Page 12: Vent Termination Clearances

    Innovative Hearth Products General Information Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 VENT TERMINATION CLEARANCES These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI Z223.1/NFPA 54) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 13 Innovative Hearth Products General Information Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Inside Corner Outside Corner Recessed Location See Table 6 Fixed Balcony with No Side Wall Balcony with Perpendicular Side Wall Openable Fixed Closed Closed Openable TERMINATION CAP AIR SUPPLY INLET GAS METER RESTRICTED AREA (TERMINATION PROHIBITED)
  • Page 14: Minimum Clearances To Combustibles

    Innovative Hearth Products General Information Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 MINIMUM CLEARANCES TO COMBUSTIBLES Fireplace And Vent Clearances The fireplace is approved with zero clearance to combustible materials on all sides (Table 8) , with the following exception: The unit may not be recessed (allowance made for mantel legs / side trim in Figure 6) . When the unit is installed with one side flush with a wall, the wall on the other side of the unit must not extend beyond the front edge of the unit (Figure 6) .
  • Page 15: Wall Finishes / Surrounds / Mantels

    Innovative Hearth Products General Information Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Table 9 - Combustible Shelf Height—Rear Vent Rear Vent with two 90° Elbows ≥3” clearance from shelf to Model Secure Vent Secure Flex ® ® top of fireplace and/or vent (using rigid elbow) (using flex elbow) pipe, whichever is higher...
  • Page 16: Installation

    Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 INSTALLATION SEQUENCE The typical sequence of installation is outlined below; however, each installation is unique and may result in variations to the steps described. See the pages referenced in the following steps for detailed instructions. Framing 1.
  • Page 17 Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Table 10 - Fireplace Framing Specifications Model Framing NOTE: Dimension “D” is the construction to be 10-1/2 required framing depth when 33-3/4” 34-1/4” 36-7/8” 14-1/2” 19-5/8” 2 x 4, or larger. 33”...
  • Page 18: Prepare The Fireplace Top Spacers

    Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Prepare the Fireplace Top Spacers 1. The two (2) 4” standoff spacers on top of the fireplace cabinet are shipped flat. Remove the screw adjacent to the detached end (Figure 8) . 2.
  • Page 19 Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Rough in the Electrical Supply, if Needed 1. As necessary, rough in the fireplace electrical supply per NEC and local codes. Install the [Optional] Blower Kit before Installation in the Framing 1.
  • Page 20: Vent System Preparation

    Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 VENT SYSTEM PREPARATION Select a Horizontal or Vertical Vent System 1. With the fireplace secured in the framing, determine the vent route and identify the exterior termination location. The following sections describe vertical (roof) and horizontal (exterior wall) vent applications. Use only approved vent components (Pages 45 and 46) .
  • Page 21: Install The Vent Restrictor (If Necessary)

    Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Install the Vent Restrictor (if necessary) 1. Use the vent run descriptions in Figure 12 to determine if a vent restrictor is necessary. 2. If necessary, assemble the vent restrictor and wing as detailed in Figure 12 and 15 . 3.
  • Page 22: Connecting The Vent Pipe

    Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Vent Restrictor with Horizontal Terminations When horizontally terminating a vent system with a vertical vent run up to 4 ft through an exterior wall, no vent restrictor is required. If installing more than 4 ft of vertical venting, install the restrictor (Figure 14) , from inside or outside the unit, in the inner fireplace collar.
  • Page 23: Vent Section Length Table

    Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Vent section length table Table 15 will assist calculating how many vent sections are needed for the planned vent configuration. When a vent section is engaged with another section, its effective length will be 1-1/2” shorter. Table 14 - Vent Section Length Nominal Section Nominal Section Length...
  • Page 24: Install The Vent System

    Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Clearance to combustibles Maintain the minimum clearance to combustibles (e.g., framing, attic, ceiling insulation, etc.). For all vertical runs: • 1” (26 mm) from all sides NOTE: Attic insulation shield (H3907) must be installed when blown or loose-fill insulation is used, and is recommended for all attic installations.
  • Page 25 Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Vertical (Offset) Installation 1. Analyze the vent route and determine the number of vent sections and elbows required—See Effective Vent Length on Pages 22 and 23 for more information. Plan the venting so that a joint does not occur in the ceiling or roof joists.
  • Page 26 Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 8. Change vent direction of horizontal/inclined run—Install the SV4.5E45 and SV4.5E90 elbows in the same manner as the straight vent sections. See Vent elbows on Page 22 for more information. 9. Continue installation of horizontal/inclined sections—Continue with the installation of the straight vent sections in horizontal/inclined run.
  • Page 27 Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Vertical Vent Figures/Tables NOTE: Secure Vent rigid vent pipe is shown in the figures; Secure Flex flexible vent pipe may also be used. ® ® NOTE: Rise per foot run ratios are acceptable all the way to level. For best results, maintain the horizontal/inclined run in a straight (no dips), slightly elevated plane of approximately 1/4”...
  • Page 28 Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Table 17 - Top Vent—Two 90° Elbows Table 18 - Rear Vent—Three Elbows Table 19 - Top Vent—Three Elbows When using Secure Flex , use ® Ceiling firestop/ ceiling firestop/ spacer SV4.5VF Wall firestop/ spacer SF4.5VF.
  • Page 29 Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Install the Horizontal Termination Vent System These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 30 Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 9. Change vent direction—At transition from or to a horizontal/inclined run, install SV4.5E45 or SV4.5E90 elbows in the same manner as the straight vent sections. The elbows feature a twist section to allow them to be routed about the center axis of their initial collar section to align with the required direction of the next vent run element.
  • Page 31 Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Figure 27 - Installing the Horizontal Termination To help minimize water infiltration it is recommended that the Firestop/Spacer (SV4.5HF) be installed on the exterior Termination side of the wall. 7” (178) 12 1/8”...
  • Page 32 Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Table 20 - Venting Components Required for Various Exterior Wall Thicknesses, when using Typical Termination Kits Vent Components Required Exterior Wall Thickness Termination Kit Only 6 to 9 1/4” (152 to 235 mm) Termination Kit and 6”...
  • Page 33 Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Table 23 - Top Vent—One 90° Elbow, Elbow Connection NOT at Fireplace H Maximum V Minimum feet meters feet meters 1.524 0.305 3.048 0.610 4.572 0.914 7.62 1.524 Ceiling firestop/ Install the U-shaped vent restrictor in any vent run with more than 4 ft of vertical spacer rise.
  • Page 34 Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Table 26 - Rear Vent—Three 90° Elbows H + H Maximum H Maximum V Minimum feet meters feet meters feet meters Wall firestop/spacer 1.524 0.610 0.305 SV4.5HF ** 3.048 1.219 0.610 4.572 1.829 0.914...
  • Page 35 Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Vertical or Horizontal Venting Using Secure Flex Kits and Components When Secure Flex kits are used in a rear flue, horizontal termination installation, at least 1 ft of vertical rise is required. ®...
  • Page 36: Complete The Field Wiring

    Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 d. 1-3/4” from the end, and that it is free from damage or tears. e. Slide the gear clamp down and tighten it fully to secure the flexible vent to the adaptor outer collar approximately 3/4”...
  • Page 37 Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 1. If installing an ON/OFF wall switch or thermostat, mount it in a convenient location on a wall near the fireplace. 2. Wire the control switch within the millivolt control circuit using the 15 ft of 2-conductor wire supplied with the unit (Figure 31).
  • Page 38 Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Electronic Wiring One of the following optional controls must be used: • ON/OFF Wall Switch, • Thermostat, or • Remote Control. See the Operation section on Page 48 for more details. NOTE: Electronic models must be connected to the main power supply.
  • Page 39: Install The [Optional] Blower Kit After Installation In The Framing

    Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Install the [Optional] Blower Kit after Installation in the Framing NOTE: For steps 11 and 12, it may be helpful to remove the control compartment door (Page 50) . FBK-100, FBK-200, and FBK-250 Kits An electrical outlet box is provided for the installation of the FBK-100, FBK-200, and FBK-250 forced air blower kits.
  • Page 40: Verify Proper Fireplace Operation

    Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Figure 34 - Control Compartment Figure 35 - Gas Line Connection 3/8 NPT x 3/8” 1/2 x 3/8” Flare Flare fitting shutoff valve valve 3/8” Flex tubing (Optional) flexible gas line connector stub 1/2 x 3/8”...
  • Page 41: Optional: Install The Firebox Liners

    Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Electronic Fireplace Inspection To light the burner, turn ON the wall or remote control switch. Ensure the igniter lights the pilot. The pilot flame should engulf the flame rod ( Figure 37 ). Figure 36 - Millivolt Pilot Figure 37 - Electronic Pilot Hood...
  • Page 42 Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Air Shutter Adjustment Guidelines • If smoke or soot is present, first check the log set positioning to ensure that the flames are not impinging on any of the logs. If the log set is properly positioned and a sooting condition persists, then the air shutter should be opened more.
  • Page 43: Install The Hood

    Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Install the Hood NOTE: All models must have a hood installed prior to operation. 1. Install the hood by sliding it into the slots on the lower edge of the cabinet top. NOTE: To install the non-combustible finish material flush with the top of the hood, the hood must be installed before installing the finish material.
  • Page 44 Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 INSTALLER - ATTACHING SAFETY-IN-OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance. ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD...
  • Page 45: Installation Accessories

    Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 INSTALLATION ACCESSORIES IMPORTANT NOTE: The installation accessories shown in this section are part of the safety agency listing for the product models represented in this manual. ® Table 30 - Listed Secure Vent Components Catalog Catalog...
  • Page 46 Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 ® Table 31 - Listed Secure Vent Components Catalog Catalog Model Description Model Description Number Number 96K93 SV4.5SU Support Strap 77L76 SV4.5E45 45° Elbow, Corrugated Horizontal Riser Kit, 14”(see 99L02 SV4.5HRK14 750146M) 77L77 SV4.5E90...
  • Page 47: Gas Conversion Kits

    Innovative Hearth Products Installation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 GAS CONVERSION KITS WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion, or the production of carbon monoxide may result;...
  • Page 48: Operation

    Innovative Hearth Products Operation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 OPERATION WARNING Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house.
  • Page 49 Innovative Hearth Products Operation Aries™ Direct-Vent Gas Fireplaces 900923-00A, 09/2019 HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD À LA SÉCURITÉ D’UTILISATION EN OPERACIÓN Your fireplace has been furnished with safety instruc- tion labels that are to be affixed to the operation and Votre foyer a été...
  • Page 50 Innovative Hearth Products Operation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Burn-in Period The first few times this fireplace is operated, there will be an odor from the curing of paint and the burning off of the lubricants used in the manufacturing process. Depending on usage, the burn-in period may take a few hours or a few days.
  • Page 51 Innovative Hearth Products Operation Aries™ Direct-Vent Gas Fireplaces 900923-00A, 09/2019 NOTE: Do NOT wire more than one valve to the burner control switch. This will help prevent excessive resistance in the burner circuit, that can cause burner operation problems. Electronic Fireplaces Detailed lighting instructions are found on Pages 65 and 66 .
  • Page 52 Innovative Hearth Products Operation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Installing the logs, volcanic stone, and glowing embers WARNING • Turn OFF all gas and electricity to the appliance before installing the volcanic stone, embers, and logs. • Do NOT install the logs until the appliance has been completely installed, the gas line connected and tested for leaks, and the initial burner operation has been confirmed.
  • Page 53 Innovative Hearth Products Operation Aries™ Direct-Vent Gas Fireplaces 900923-00A, 09/2019 Installing the logs - 33” Traditional Models The logs have notches/tabs to assist proper positioning. Upper logs rest on lower logs via notches/tabs. Proper log placement is critical to prevent sooting. Place the logs in the gaps between flame peaks, so they do not impinge the flames.
  • Page 54 Innovative Hearth Products Operation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Installing and removing the glass door WARNING • Do not attempt to substitute the materials used on these doors, or replace cracked or broken glass. • Handle this glass with extreme care! Glass is susceptible to damage—Do not scratch or handle roughly while reinstalling the glass door frame.
  • Page 55 Innovative Hearth Products Operation Aries™ Direct-Vent Gas Fireplaces 900923-00A, 09/2019 Installing the glass door 1. Visually inspect the gasket on the backside of the glass door. NOTE: The gasket surface must be clean, free of irregularities, and seated firmly. Ensure it is properly located. Make sure the bead is not rolled into the channel at the top of the door, but remains flat against the top of the glass.
  • Page 56: Maintenance

    Innovative Hearth Products Operation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 MAINTENANCE Refer to the Maintenance Schedule on Page 59 for maintenance tasks, procedures, frequency, and a listing of by whom the tasks should be performed. Always verify proper fireplace operation after servicing. WARNING Turn OFF gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
  • Page 57 Innovative Hearth Products Operation Aries™ Direct-Vent Gas Fireplaces 900923-00A, 09/2019 Inspecting the glass gasket Visually inspect the gasket on the backside of the glass door. The gasket surface must be clean, free of irregularities, and seated firmly. Cleaning the control compartment Keep the control compartment clean by vacuuming or brushing it out at least twice a year.
  • Page 58 Innovative Hearth Products Operation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Glass Media Removing and cleaning the glass media CAUTION Risk of personal injury. Allow the media to completely cool before handling. Use a clean, dry, empty shop vac to remove glass media. Wash the media in warm, soapy water. Rinse and dry before reinstalling.
  • Page 59 Innovative Hearth Products Operation Aries™ Direct-Vent Gas Fireplaces 900923-00A, 09/2019 MAINTENANCE SCHEDULE See the tables below for detailed information about required maintenance, both regular and annual. Maintenance Performed Annually—Before the Burning Season Maintenance Task Performed By Performed By Inspecting/Cleaning Burner, Logs Qualified Service Technician Inspect valve and ensure it is properly operating.
  • Page 60: Accessory Components

    Innovative Hearth Products Operation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 ACCESSORY COMPONENTS Touch-Up Paint Kits Repair minor scratches and discoloration of the fireplace black painted surfaces with the touch-up paint kits. Touch-Up Paint Kit Catalog No. Model Description F4032 HTIPSB Black touch-up paint, firebox interior F1882 SCTPSAB Black touch-up paint, powder coat exterior...
  • Page 61 Innovative Hearth Products Operation Aries™ Direct-Vent Gas Fireplaces 900923-00A, 09/2019 Thermostatic Control Kits Feature a thermostatic ON/OFF mode as well as manual ON/OFF operation. Thermostatic Control Kits - Millivolt Models RC-S-STAT, Thermostatic or manual operation Catalog Number • LCD display •...
  • Page 62 Innovative Hearth Products Operation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 ACCESSORY COMPONENTS (continued) Unit-Mountable Rocker Switch Kit This rocker switch kit can be installed directly in the control compartment to provide ON/OFF operation in lieu of a wall switch. Unit-Mountable Rocker Switch Catalog Model 80L41...
  • Page 63: Lighting Instructions

    Innovative Hearth Products Operation Aries™ Direct-Vent Gas Fireplaces 900923-00A, 09/2019 LIGHTING LABEL, MILLIVOLT GAS VALVE - ENGLISH FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 64 Innovative Hearth Products Operation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 LIGHTING LABEL, MILLIVOLT GAS VALVE - FRENCH POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 65 Innovative Hearth Products Operation Aries™ Direct-Vent Gas Fireplaces 900923-00A, 09/2019 LIGHTING INSTRUCTIONS, ELECTRONIC - ENGLISH FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 66 Innovative Hearth Products Operation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 LIGHTING INSTRUCTIONS, ELECTRONIC - FRENCH POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 67: Troubleshooting

    Innovative Hearth Products Operation Aries™ Direct-Vent Gas Fireplaces 900923-00A, 09/2019 TROUBLESHOOTING Before troubleshooting, ensure that the fireplace main line gas shutoff valve and the wall switch are in the ON position. The following troubleshoots the fireplace only to an elementary level. For detailed remote and ignition system troubleshooting, refer to the instructions provided with the remote.
  • Page 68 Innovative Hearth Products Operation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 Troubleshooting Electronic Systems SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Nothing happens a. Remote is not functioning properly. Check that the wall switch plate is set to REMOTE. when the fireplace is Operate the fireplace from the wall plate switch.
  • Page 69: Replacement Parts

    Innovative Hearth Products Operation Aries™ Direct-Vent Gas Fireplaces 900923-00A, 09/2019 REPLACEMENT PARTS Cat. No. Model Weight Cu. Ft. Cat. No. Model Weight Cu. Ft. Cat. No. Model Weight Cu. Ft. Cat. No. Model Weight Cu. Ft. F1675 Aries33TMN 88 lb. 11.0 F1681 Aries33RMN...
  • Page 70 Innovative Hearth Products Operation Aries™ Direct-Vent Fireplaces 900923-00A, 09/2019 REPLACEMENT PARTS (CONTINUED) 33” Models Description Catalog Number Glass Door F1905 Electronic Pilot Assembly, Natural Gas H7268 Electronic Pilot Assembly, Liquid Propane H7269 Electronic DFC Wire Harness Assembly H8601 Electronic DFC Ignition Board J7906 Electronic Power Transformer H8006...
  • Page 71: Warranty

    Innovative Hearth Products Astria ® Brand Gas Fireplace Limited Lifetime Warranty THE WARRANTY Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your Astria ® brand gas fireplace ("Product") to be free from defects in materials and workmanship at the time of manufacture. The product body, firebox and barrier carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime Warranty against thermal breakage only.
  • Page 72 Installation and Operation Instructions Innovative Hearth Products 900923-00A, 09/2019 Aries™ Direct-Vent Gas Fireplaces Astria.us.com Record the following important information about your fireplace: Fireplace model number Fireplace serial number Date fireplace was Installed Type of gas fireplace uses Dealer name Innovative Hearth Products (IHP) reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.

This manual is also suitable for:

Aries33tmnAries33tenAries33rmnAries33renAries33tmpAries33tep ... Show all