INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
In the Commonwealth of Massachusetts:
Installation must be performed by a licensed plumber or
gas fitter;
• See Table of Contents for location of additional Common-
wealth of Massachusetts requirements.
WARNING: If the information in this manual is
not followed exactly, a fire or explosion may
result causing property damage, personal injury
or loss of life.
FOR YOUR SAFETY: Do not store or use gasoline
or other flammables or liquids in the vicinity of
this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow your gas suppliers
instructions.
• If your gas supplier cannot be reached, call
the fire department.
Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
C
US
Atlas42ZP2 Shown
Report No. F14-168
INSTALLATION AND

OPERATION INSTRUCTIONS

UNIVERSAL VENT-FREE FIREBOX
36" x 24", 36" x 28" & 42" x 28" Universal Vent-Free Fireboxes
P/N 900238-00 REV. C 09/2018
MODELS
Atlas36ZP2
Atlas36ZP3
FOR USE ONLY WITH A LISTED GAS-FIRED
UNVENTED DECORATIVE ROOM HEATER NOT TO
EXCEED 40,000 BTU/H.
DO NOT BUILD A WOOD FIRE.
WARNING: IMPROPER INSTALLATION, ADJUST-
MENT, ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE INJURY OR PROPERTY DAMAGE.
REFER TO THIS MANUAL. FOR ASSISTANCE OR
ADDITIONAL INFORMATION CONSULT A QUALI-
FIED INSTALLER, SERVICE AGENCY OR THE GAS
SUPPLIER.
Carefully review the instructions supplied with
the decorative type unvented room heater for the
minimum fireplace size requirement.
DO NOT INSTALL AN APPLIANCE IN THIS FIREBOX
UNLESS THIS FIREBOX MEETS THE MINIMUM
DIMENSIONS REQUIRED FOR THE INSTALLATIONS.
THIS IS A VENT-FREE GAS-FIRED HEATER ENCLO-
SURE. IT USES AIR (OXYGEN) FROM THE ROOM
IN WHICH IT IS INSTALLED. PROVISIONS FOR
ADEQUATE COMBUSTION AND VENTILATION AIR
MUST BE PROVIDED. REFER TO COMBUSTION
AND VENTILATION AIR SECTION, PAGES 3 & 4.
Due to high temperatures, the appliance should be located out
of traffic and away from furniture or draperies.
Do not place clothing or other materials on or near this appliance.
IMPORTANT: READ AND UNDERSTAND THESE INSTRUCTIONS
COMPLETELY BEFORE INSTALLING YOUR VENT-FREE ROOM
HEATERS.
Atlas42ZP2
Atlas42ZP3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Atlas36ZP2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Astria Fireplaces Atlas36ZP2

  • Page 1: Operation Instructions

    INSTALLATION AND OPERATION INSTRUCTIONS UNIVERSAL VENT-FREE FIREBOX 36" x 24", 36" x 28" & 42" x 28" Universal Vent-Free Fireboxes P/N 900238-00 REV. C 09/2018 MODELS Atlas36ZP2 Atlas42ZP2 Atlas36ZP3 Atlas42ZP3 Atlas42ZP2 Shown P900238-00 INSTALLER: Leave this manual with the appliance.
  • Page 2: Important Safety Information

    IMPORTANT SAFETY WARNING WARNING INFORMATION Carbon Monoxide Poisoning: Early • The heater must be isolated from INSTALLER: PLEASE LEAVE THESE INSTRUC- signs of carbon monoxide poisoning the gas supply piping system by TIONS WITH THE OWNER. closing its individual manual are similar to the flu with head- OWNER: PLEASE RETAIN THESE INSTRUC- shut-off valve during any pres-...
  • Page 3: Table Of Contents

    4th floor New York, NY 10036) or National Fire Vent-Free Gas Firebox non-toxic odors during this process. Protection Association, Inc. (1 Batterymarch Hood (optional for models Atlas36ZP2, Atlas36ZP3, Park Quincy, MA 02169-7471). Depending on your use, the burn-in period may Atlas42ZP2 and Atlas42ZP3) Installation and Operation Instructions take a few hours or a few days.
  • Page 4: Combustion And Ventilation Air

    COMBUSTION AND VENTILATION AIR c. caulking or sealants are applied to areas ________ (volume of space) x 20 = (Maxi- mum BTU/Hr the space can support) such as joints around window and door Example: 3,168 cu. ft. (volume of space) x frames, between sole plates and floors, WARNING 20 = 63,360 (maximum BTU/Hr space can...
  • Page 5: Cold Climate Insulation

    COLD CLIMATE INSULATION LOCATION OF FIREBOX WARNING Carefully select the best location for installation For cold climate installations, seal all cracks Do not install these built-in Vent- of your built-in Vent-Free firebox. The following around the appliance with noncombustible factors should be taken into consideration: Free fireboxes in sleeping quarters, material and wherever cold air could enter or in recreational vehicles.
  • Page 6: Clearances

    Clearances Ceiling clearance: The ceiling must be at least 40" from the top of the firebox opening (Figure 2). Ensure the minimum clearances shown in Figures 2 through 6 are Noncombustible material: Noncombustible materials, such as slate and maintained. Left and right clearances are determined when facing the marble, must be at least 1/2"...
  • Page 7 To install the firebox with a wood mantel, shelf or other combustible projection above firebox opening. Refer to Figures 4 and 5. Models Atlas36ZP2 and Atlas42ZP2 WITH Hood Installed Hood is optional on these models Minimum clearance requirements include any projections such as shelves, window sills, mantels, etc., above the appliance.
  • Page 8: Assembly Steps

    ASSEMBLY STEPS Consult all local codes. IMPORTANT NOTES: Properly size and route the gas supply line • Illustrations shown in this manual reflect Hold heater regulator with a wrench from the supply regulator to the area where the “typical” installations with nominal dimen- appliance is to be installed per requirements to prevent movement when connect- sions and are for design and framing refer-...
  • Page 9: Firebox Framing

    Firebox Framing 3. Note the floor construction, i.e. 2" x 6", 2" x NOTE: The nailing flange and the area directly behind the nailing flange is exempt from the 8" or 2" x 10", single or double joists, type clearances described on the firebox clearance Construct firebox framing following Figures 8 and thickness of floor boards.
  • Page 10: Specifications

    36” 42” Cat. No. Model Ship. Weight (lbs) Shipping Volume 22 Cu. Ft. Front Width 35 (889) 41 (1042) F0391 Atlas36ZP2 200 lbs Rear Width 23-1/4 (591) 29-1/4 (743) 22 Cu. Ft. F0392 Atlas36ZP3 200 lbs 26 Cu. Ft. Depth...
  • Page 11: Framing Specifications

    FRAMING SPECIFICATIONS Corner Installation Framing Dimensions Back Wall Of Chase/Enclosure This Figure corresponds to Table 1 Opening Atlas36 Series Atlas42 Series Including Finishing Materials If Any 42-1/4" (1073) 48-1/4" (1226) 44-1/4" (1124) 44-1/4" (1124) 23-5/8" (600) 29-5/8" (753) 11-1/4" (286) 14-1/4"...
  • Page 12: Optional Equipment / Blower Kit Installation

    IMPORTANT Top View * Junction Box * Electrical Outlet The Ground Lead must be connected to the green screw (located on the Hood junction box). Failure to do this Blower could result in an electrical short or Bend blower mounting shock injury.
  • Page 13 Page 14). Step 1. Follow the instructions below for the model you are installing: Models Atlas36ZP2, Atlas36ZP3, Atlas42ZP2 and Atlas42ZP3: Screw Lift out the bottom refractory panel (see Figure 16). Step 2. Remove the rectangular knock-out (for J-Box) on the right side of unit (see Figure 7 for location).
  • Page 14 Step 6. Route a 3-wire, 120 VAC, 60 Hz, 1 ph power supply to the right side of appliance. Models Atlas36ZP2, Atlas36ZP3, Atlas42ZP2 and Atlas42ZP3: Reinstall the bottom refractory panel that was removed on Step 1 Step 7. Locate the J-Box cover (provided in J-Box Kit). Remove the round (see Figure 16).
  • Page 15: Firebox Finishes

    FIREBOX FINISHES APPROVED ACCESSORIES AND COMPONENTS There are a wide variety of “finished looks” for your built-in Vent-Free firebox from formal wall decor with elaborate mantels to rustic wood paneling or warm brick facings. Only noncombustible materials like marble, stone, tile, brick, etc. may overlap the black front facing.
  • Page 16 APPROVED ACCESSORIES AND The variable speed control COMPONENTS rheostat is included with FBK-200 models only * Forced Air Blower Kits Cat. Model No. Description Blower, Standard 80L84 FBK-100 (single speed) Blower, Variable Speed 80L85 FBK-200 (w/wall-mounted switch) Black Hood Cat. # Model Models Where Used Atlas36 Series...
  • Page 17: Replacement Parts List

    Astria.us.com. WARNING REFRACTORY PANELS LIFTING HAZARD SINGLE - PERSON LIFT COULD CAUSE INJURY. USE ASSISTANCE WHEN MOVING OR LIFTING. Atlas36ZP2 (WS) Atlas36ZP3 (WH) Atlas42ZP2 (WS) Atlas42ZP3 (WH) Description Whited Stacked Whited Herringbone Whited Stacked Whited Herringbone Part No.
  • Page 18 NOTES ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...
  • Page 19: Warranty

    Innovative Hearth Products Astria Brand Gas Fireplace ® Limited Lifetime Warranty THE WARRANTY Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your Astria brand gas fireplace ("Product") to be free from defects in materials and workmanship ® at the time of manufacture. The product body, firebox and barrier carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime Warranty against thermal breakage only.
  • Page 20 IHP reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and the discontinuance of colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2013 Innovative Hearth Products P/N 900238-00 REV.

This manual is also suitable for:

Atlas42zp3Atlas36zp3Atlas42zp2

Table of Contents