Mitsubishi Electric MUZ-HJ25VA-E2 Service Manual page 6

Outdoor unit
Table of Contents

Advertisement

Outdoor model
Power supply
Capacity
Rated frequency (Min.-Max.)
Breaker Capacity
Power input 1 (Set)
Running current 1 (Set)
Power factor 1 (Set)
Starting current 1 (Set)
Coeffi cient of performance
(COP) 1 (Set)
Model
Output
Compressor
Current 1
Refrigeration oil (Model)
Model
Fan motor
Current 1
Dimensions W × H × D
Weight
Dehumidifi cation
Cooling
Air fl ow 1
Heating
Sound level 1
Cooling
Fan speed
Heating
Fan speed regulator
Refrigerant fi lling capacity (R410A)
NOTE: Test conditions are based on ISO 5151.
Cooling: Indoor
Outdoor Dry-bulb temperature 35°C
Heating: Indoor
Outdoor Dry-bulb temperature 7°C
Refrigerant piping length (one way): 5 m
1 Measured under rated operating frequency.
OBH648F
Cooling
kW
Heating
A
Cooling
W
Heating
Cooling
A
Heating
Cooling
%
Heating
A
Cooling
Heating
W
Cooling
A
Heating
L
Cooling
A
Heating
mm
kg
Cooling
L/h
High
Med.
Low
3
m
/h
High
Med.
Low
Cooling
dB(A)
Heating
High
Med.
Low
rpm
High
Med.
Low
kg
Dry-bulb temperature 27°C
Dry-bulb temperature 20°C
MUZ-HJ50VA
Single phase, 230 V, 50 Hz
5.0 (1.3 - 5.0)
5.4 (1.4 - 6.5)
12
2,050
1,480
9.0
6.6
99
97
9.0
2.44
3.65
SNB130FGBHT
8.5
5.9
0.45 (NEO22)
RC0J50-FA
0.27
0.34
800 × 550 × 285
36
2.2
1,872
1,872
1,086
2,088
1,776
1,386
50
51
810
810
490
900
770
610
1.15
Wet-bulb temperature
Wet-bulb temperature
6
MUZ-HJ60VA
MUZ-HJ71VA
6.1 (1.7-7.1)
6.8 (1.5-8.4)
16
1,900
1,970
8.4
8.7
98
98
8.7
3.21
3.45
SNB130FGBMT
900
7.0
7.4
0.35 (FV50S)
RC0J77-AF
0.94
0.94
840 × 880 × 330
55
1.6
3,244
2,871
1,566
2,871
2,871
2,331
55
55
950
450
810
810
650
3
1.80
19°C
6°C
7.1 (1.8-7.1)
8.1 (1.5-8.5)
2,330
2,440
10.3
10.8
10.8
3.05
3.32
8.8
9.4
0.97
2.4
2,960
840