Download Print this page

Troubleshooting - EXPERT GRILL XG18-101-002-07 Owner's Manual

Outdoor lp gas barbecue grill

Advertisement

Problem
• LP gas tank valve is closed
• LP gas tank is low or empty
• LP gas leakage
Burner will
not light using
• Wires or electrode covered with cooking residue
igniter
• Electrode and burners are wet
• Electrode cracked/broken - sparks at crack
• Wire loose or disconnected
• Wire is shorting (sparking) between ignitor and electrode • Replacement part(s) may be needed
• Bad igniter
• No gas flow
• LP gas tank is low or empty
• LP gas
Burner will
not light with
match
• Coupling nut and regulator not fully connected
• Obstruction of gas flow
• Disengagement of burner to valve
• Spider webs or insect nest in venturi
• Burner ports clogged or blocked
• Out of gas
Sudden drop
in gas flow or
reduced flame
• Overfilling prevention device may have been activated
height
Irregular flame
pattern, flame
does not run
• Burner ports are clogged or blocked
the full length
of burner
• New burner may have residual manufacturing oils
Flame is yellow
• Spider webs or insect nest in venturi
or orange
• Food residue, grease, etc . on burners
• Poor alignment of valve to burner/venturi tube
• High or gusting winds
• Low on LP Gas
Flame goes out
• Overfilling prevention device may have been activated

Troubleshooting

Possible Cause
Prevention/Cure
• Make sure regulator is securely attached to the LP gas tank
per "Installing LP Gas Tank," then turn LP gas tank valve to
"OPEN"
• Exchange, refill or replace LP gas tank
• Turn LP gas tank valve to "CLOSED"
• Wait 5 minutes for gas to clear
• Follow "Checking for Leaks" section
• Clean wire and/or electrode with rubbing alcohol
• Wipe dry with cloth
• Replacement part(s) may be needed
• Reconnect wire or replacement part(s) may be needed
• Replacement part(s) may be needed
• Check if LP gas tank is empty
A . If empty, exchange, refill or replace LP gas tank
B . If LP gas tank is not empty, refer to "Sudden drop in gas
flow or reduced flame height" (see below)
• Exchange, refill or replace LP gas tank
• Turn LP gas tank valve to "CLOSED"
• Wait 5 minutes for gas to clear
• Follow "Checking for Leaks" section
• Turn the coupling nut about one-half to three-quarters
additional turn until solid stop . Tighten by hand only - do NOT
use tools
• Clear burner/venturi tube
• Check for bent or kinked hose
• Reengage burner and valve
• Clean burner/venturi tube
• Clean burner ports
• Exchange, refill or replace LP gas tank
1 .
Turn control knobs to " OFF"
2 .
Wait 30 seconds and light grill
3 .
If flames are still too low, reset the overfilling prevention
device:
a .
Turn control knob(s) " OFF"
b .
Turn LP gas tank valve to "CLOSED"
c .
Disconnect regulator
d .
Turn control knobs to (HIGH)
e .
Wait 1 minute
f .
Turn control knobs to " OFF"
g .
Reconnect regulator and leak check connections,
being careful not to fully open valve
h .
Light grill per "Lighting" section
• Clean burner ports
• Burn grill for 15 minutes on
• Clean venturi
• Clean burner
• Ensure burner/venturi tube is properly engaged with valve
• Do not use grill in high winds
• Exchange, refill or replace LP gas tank
• Refer to "Sudden drop in gas flow or reduced flame height"
(see above)
15
(HIGH) with the lid closed

Advertisement

loading

This manual is also suitable for: