Download Print this page

EXPERT GRILL XG18-101-002-07 Owner's Manual page 12

Outdoor lp gas barbecue grill

Advertisement

12
Checking for Leaks
Burner Connections
1 .
Make sure the regulator hose and valve connections are securely fastened to the burner
and the tank .
2 .
Visually check the connection between the burner/venturi tube and orifice .
3 .
Make sure the burner/venturi tube fits over the orifice .
W WARNING: Failure to inspect this connection or follow these
instructions could cause a fire or an explosion which can cause
death, serious bodily injury or damage to property.
4 .
Please refer to diagram for proper installation (Figure 1) .
5 .
If the burner/venturi tube does not rest flush to the orifice, as shown .
Tank/Gas Line Connection
1 .
Make 2-3 oz . of leak detection solution by mixing one part liquid dishwashing soap with
three parts water .
2 .
Make sure control knobs are in the " OFF" position (Figure 2) .
3 .
Connect LP gas tank per "Installing LP Gas Tank" section .
4 .
Turn LP gas tank valve to "OPEN ."
5 .
Spoon several drops of solution, or use a squirt bottle, at all "X" locations (Figures 1 and
3) .
a . If any bubbles appear, turn LP gas tank valve to "CLOSED," reconnect and re-test .
b . If you continue to see bubbles after several attempts, turn LP gas tank valve to
"CLOSED" and disconnect LP gas tank, per "Disconnecting LP Gas Tank" section .
c . If no bubbles appear after one minute, turn LP gas tank valve to "CLOSED," wipe
away solution and proceed .
Operating Main Burners
First Use
1 .
Make sure all labels, packaging and protective films have been removed from the grill .
2 .
Remove manufacturing oils before cooking on this grill for the first time by operating
the grill for at least 15 minutes on (HIGH) with the lid closed . This will "heat clean" the
internal parts and dissipate odors .
Lighting
W CAUTION: Keep outdoor gas cooking appliance area clear and free from
combustible materials, gasoline and other flammable vapors and liquids.
W CAUTION: Do NOT obstruct the flow of combustion and ventilation air.
W CAUTION: Check and clean burner/venturi tubes for insects and insect nests.
clogged tube can lead to a fire.
W CAUTION: Attempting to light the burner with the lid closed may cause an
explosion.
1 .
Open lid .
2 .
Check for obstructions of airflow to the burners . Spiders, insects and webs can clog the
burner/venturi tube . A clogged burner tube can lead to a fire .
3 .
All control knobs must be in the " OFF" position (Figure 2) .
4 .
Connect LP gas tank per "Installing LP Gas Tank" section .
5 .
Turn LP gas tank valve to "OPEN ."
6 .
Push and turn control knob to (HIGH) . the burner should light . Repeat up to three times .
7 .
If ignition does not occur in 5 seconds, turn burner control knob " OFF," wait 5 minutes,
and repeat lighting procedure .
8 .
If igniter does not light burner, use a lit match secured with the lighting rod (included with grill) to light burners . Access the burners
through the cooking grid and heat plates . Position lit match near side of burner (Figure 4) .
Important: Always use the lighting rod (included) when lighting burners with a match .
9 .
After lighting, observe the burner flame . Make sure all burner ports are lit and flame height matches illustration (Figure 5) .
Note: Each burner lights independently - repeat steps 5-9 for the other burners .
Operating Instructions
Figure 1
Figure 2
Figure 3
X
X
X
X
X
Figure 4
A
Figure 5
Flame
Slight
Yellow
Slight
Blue
Burner
Dark
Blue

Advertisement

loading

This manual is also suitable for: