Emerson SUMMER NIGHT CF742PFSCB 01 Owner's Manual

Emerson SUMMER NIGHT CF742PFSCB 01 Owner's Manual

Hide thumbs Also See for SUMMER NIGHT CF742PFSCB 01:

Advertisement

Quick Links

READ AND SAVE THESE INSTRUCTIONS
SUMMER NIGHT
42" Damp Location
Ceiling Fan
Owner's Manual
Net Weight:
What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials.
You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for ten years from the date you purchased your ceiling fan. All other components and accessories are
covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Electric Co. Do To Correct Problems:
Emerson Electric Co. will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of the
motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson will refund the actual purchase price of
your fan. We will ship the repaired product or replacement to you at no charge, but you are responsible for all costs or removal, reinstallation and shipping of
the product to Emerson Electric Co.
How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF
OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of
Emerson Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.
• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Air Comfort
Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage.
What Is Not Covered:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any defects, malfunctions or failures
caused by:
• Repairs by persons not authorized by Emerson Electric Co.,
• Use of parts or accessories not authorized by Emerson Electric Co.,
• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
• The original purchaser or user ceases to own the product, or
• The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee,
agent, dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE
FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such damages
as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if
this product does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Part No. F40BP73130000
®
11.7
Lbs.

LIMITED WARRANTY

Model No.
CF742PFWW 01
CF742PFSCB 01
Form No. BP7313
U.L. Model No.: CF742PF

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SUMMER NIGHT CF742PFSCB 01 and is the answer not in the manual?

Questions and answers

Summary of Contents for Emerson SUMMER NIGHT CF742PFSCB 01

  • Page 1 What Will Emerson Electric Co. Do To Correct Problems: Emerson Electric Co. will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson will refund the actual purchase price of your fan.
  • Page 2 6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician. WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically approved for this fan.
  • Page 3 Emerson Electric Co. Substitution of parts or 4. One pull chain coupling accessories not designated for use with this product 5. Three wire connectors by Emerson Electric Co. could result in personal 6. One clevis pin injury or property damage. 7. One hairpin clip 8.
  • Page 4 M5 x 13 FLANGE HANGER BALL/ SCREWS DOWNROD ASSEMBLY CEILING COVER CLEVIS CLEVIS HAIRPIN SETSCREW CLIP SETSCREW BLADE ASSEMBLY Figure 1 Figure 3 MOTOR COUPLING NOTE: Remove and discard five shipping spacers 4. Reinstall the two setscrews in the motor coupling. and screws from the motor hub.
  • Page 5 How to Hang Your Ceiling Fan WARNING WARNING Failure to seat tab in groove could cause damage to The fan must be hung with at least 7' of clearance electrical wires and possible shock or fire hazard. from floor to blades (Figure 4). NOTE: CEILING COVER, CEILING SUPPLY WIRES AND...
  • Page 6 NOTE: If you are using an Emerson light fixture 5. Secure the ceiling cover in place by sliding with your fan, remove the three screws securing lockwashers over the threaded studs and installing the the switch housing cover to the switch housing two knurled knobs (supplied).
  • Page 7 Emerson Electric Co. Substitution of parts or accessories not designated for use with this product To reduce the risk of fire or electrical shock, do not by Emerson Electric Co. could result in personal use this fan with any solid-state speed control injury or property damage.
  • Page 8 The model number of your Fan will be found on a label attached to the top housing. For repair parts, phone 1-800-654-3545. Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant ¥ St. Louis, MO 63136 Printed in China 09/07 Part No. F40BP73130000 Form No.

This manual is also suitable for:

Summer night cf742pfww 01

Table of Contents