Before calling your supplier please make sure that:
Problem
The appliance is not functioning
The appliance is not cooling or
it is not reaching the required
temperature
There is something other than
the temperature displayed on the
controller
If the reason for the malfunction cannot be identified, disconnect the electrical supply from the appliance and
contact your authorised dealer or Foster Service. When requesting a service call, please quote the model and
serial number which can be found on the inside of the appliance on the right hand wall and begins with 'E' .
G3 Counters - User Manual
Check
Is the appliance plugged in and
the socket switched on?
Has the fuse blown?
Is the appliance switched on?
Is the condenser blocked or dirty?
Is the appliance positioned close
to a heat source?
Is the appliance loaded correctly?
Is the display showing one of the
alarms/warnings above?
Solution
If the appliance is plugged in
check that the socket is 'live' by
plugging another appliance in to
see if that works.
Check the fuse and if necessary
change it for a new one
Check that the temperature is
displayed. If the display shows 'oFF'
switch on the appliance as it is in
standby
Inspect and clean the condenser
if necessary as described in this
manual
Is the heat source affecting the
performance of the appliance. If
possible move the appliance away
from the heat source.
Check the loading of the product
contained in the appliance is in
accordance with the guidelines in
this manual
The display may show indications
shown in the 'Alarms and
Warnings' section of these
instructions. For anything else
contact your authorised dealer or
Foster Service.