Regular Maintenance

Where the regular cleaning regime previously described
does not remove dirt or grease deposits from the
condenser, it should be cleaned by a competent
engineer. We recommend that an engineer services
the appliance every 6 to 12 months to maintain your
warranty and ensure optimal performance of your
6-12 MONTHS
appliance. We recommend that service is carried out by
an authorised Foster agent or by contacting the Foster
Service team using the contact details in this manual.

Troubleshooting

Alarms/Warnings:
During operation the current temperature inside the appliance will be
displayed. At certain times this will change to indicate a particular appliance
operation or fault. The indicators you may see are as follows:
hi - The internal temperature of the appliance is higher than it should be. Ensure that the door is closed and
that the air flow inside is not obstructed by excesive or poor loading of product. The alarm will reset if the
temperature falls to a normal level. If this does not happen please contact your authorised dealer or Foster
Service.
Lo - The internal temperature of the appliance is lower than it should be. Check to ensure that the appliance
has not been loaded with product at a lower temperature than the normal appliance operating
temperature. If this is not the case please call your authorised dealer or Foster Service.
tA - This indicates that the internal temperature probe has failed. Call your authorised dealer or Foster Service
to arrange for this to be replaced. During this time the appliance cannot maintain an accurate temperature
and all product should be removed and the appliance switched off.
tE - This indicates that the evaporator probe has failed. Call your authorised dealer of Foster Service to arrange
for this to be replaced.
PF - The mains power has been removed from the appliance for a period of time and has now been restored.
This may have resulted in a rise in appliance temperature. Caution should be taken when using products
stored within to ascertain whether these products are suitable for use. Upon restoration of the power supply
the appliance will resume normal operation and the PF can be cancelled by pressing button 3 once.
HC - The condenser temperature is higher than it should be. If the appliance is being subjected to particularly
high ambient temperatures steps should be taken to reduce this. If the ambient temperature is not high or
reducing the temperature does not rectify the fault please contact your authorised dealer or Foster Service.
Cnd - The condenser clean period has expired. Please contact your authorised dealer or Foster Service.
While in an alarm condition icon 5 will also be illuminated.
(Some indications are only visible periodically during specific appliance operations such as defrost or when activated
through use of the appliance).