Toshiba RAS-25N4KVRG-ND Service Manual page 122

Hide thumbs Also See for RAS-25N4KVRG-ND:
Table of Contents

Advertisement

No.
Part name
Cross flow fan
1) Follow the procudure item ⑧ and ⑩.
10
2) Loosen the set screw of the cross flow fan.
3) Remove 2 fixing screws from the bearing base
4) Lift up the heat exchanger follow the figure.
<To re-installation>
1) To incorporate the fan motor and the motor into the
- Install the cross flow fan so that the right end if
Procedures
Hexagon screw driver
and 3 fixing screws of evaporator, then remove it
from the main unit.
Screws
Pull out the left hand side until the cross flow fan
released from the shalf of the fan motor and
thenpull out the lower side of heat exchanger
follow the figure.
position in the following figure.
the 1st joint from the right of the cross flow fan is
keep 5mm from closed wall of the main unit.
Screws of
evaporator
- 122 -
Remarks
Bearing base