Cavius 2208 Installation Manual page 2

Mains powered smoke alarm

Advertisement

For cathedral or peak ceiling:
Peak ceiling
5. INSTALLING THE SMOKE ALARM:
NOTE: THIS ALARM NEEDS TO BE INSTALLED
BY A PROFESSIONAL.
MAKE SURE ELECTRICITY IS SWITCHED OFF
BEFORE STARTING THE INSTALLATION.
CAUTION: LIVE, NEUTRAL AND EARTH MUST
BE CORRECTLY INSTALLED AND NOT MIXED UP.
NOTE: The alarm is delivered in the packaging
with a dust cover, installed to protect the alarm for
exposure to excessive dust which could potentially
damage or reduce the function of the alarm while
the building is under construction. The dust cover
must be removed after the building is fully cleaned.
OPTION 1: ALARM MOUNTED ON MOUNTING
BASE OUT ON THE CEILING:
Use the mounting base ring to mark the screw
holes on the ceiling.
MARK UP
4 SCREW HOLES
WITH A PEN
For surface wiring pass the feed wire through
the mounting base cable holder and screw after
termination.
Connect the 3 wires to the power supply: Live
feed (L1), neutral (N), earth (
).
L2
L1
N
N
L1
L2
Screw the mounting base on the ceiling.
Screw the power supply on the mounting base.
Once the mounting base with power supply is
installed, attach the alarm by twisting clockwise
until it clicks.
OPTION 2: ALARM MOUNTED ON TOP OF
CONDUIT BOX:
Connect the 3 wires from the conduit box on the
alarm power supply:
2
Live feed (L1), neutral (N), earth ( ).
Screw the power supply on conduit box.
USE THE
ENCLOSED
SCREWS AND
PLUGS
NOTE: Mounting base is not used when
the alarm is installed on conduit box.
6. SAFETY LOCK:
7. TEST FUNCTION:
After installation, and at least once per quarter,
test all of your alarms to ensure they are operating
correctly and are within range of each other.
It is recommended to check visually every week if
the LED flashes correctly (every 48sec.).
Press the test button on any alarm for at least
10 seconds.This will send out a test signal
from the alarm; all other connected alarms
should receive the signal within a short time.
The alarms will emit a short beep and the LED
will flash every 8 seconds for 2 minutes.
NOTE: Test function also transmits a weaker RF
signal to ensure an optimal operation in normal
conditions.
When the test signal is sent out, the alarms will
respond in two ways:
1. A single beep every 8 seconds indicates that
the alarms are connected and functioning.
2. Three short beeps every 8 seconds indicates a
smoke sensor fault. The alarm should be cleaned
by running the vacuum (on a low setting) around
the smoke alarm chamber and tested again.