Programming; Required Parts; Connecting The Cm With The Base Station - Access Flow2 User's Manual & Installation Instructions

Communication module
Hide thumbs Also See for Flow2:
Table of Contents

Advertisement

7

Programming

2
Programming
To connect the CM to the landline, it must be connected to the base station of a DECT telephone.
If a DECT telephone is already present, it can be used*. If this is not the case, a base station can
be supplied by thyssenkrupp.
2.1

Required parts

-
Communication module in the arm rest.
-
DECT base station.
If possible, position the base station halfway up the rail. For the situations where the base station
cannot connect to the CM because of the distance, a DECT amplifier can be used. (Not supplied
by thyssenkrupp).
Connect the landline to the base station. Connect the base station to the mains supply using the
adapter.

2.2 Connecting the CM with the base station

5 s
1
Press the "connect / verbind" button on the base station for 5 seconds (this is brand/type
dependent, if this does not work, consult the base station manual).
2
When the CM is searching for the base station, the light on the alarm button flashes red.
3
The registration has been successful if two beep sounds are heard and the light on the
alarm button turns off. The CM is now connected to the base station (The CM can only be
linked to one base station at a time).
*The Communication Module connects to every brand of DECT base station (GAP / ETSI standard
EN 300444)