Appendix 19: Cable Specifications

TANDBERG MXP and Classic Endpoints that support External
Network
External Network Pinout
With respect to signals on the NET port:
For balanced signals a "0"=low voltage is defined as terminal A positive with respect to
terminal B.
For unbalanced signals a "0"= low voltage is defined as terminal positive with respect to
GND.
Pinout on 26-pin HD connector J5
Standard
Pin
numb
V35
RS449
1
GND
GND
2
3
4
5
6
7
8
9
10
11
SD (A)
SD (A)
12
SD (B)
SD (B)
13
RD (A)
RD (A)
14
RD (B)
RD (B)
15
SCR
SCR(A)
(A)
16
SCR
SCR(B)
(B)
17
SCT
SCT(A)
(A)
18
SCT
SCT(B)
(B)
19
GND
GND
20
TR (A)
21
TR (B)
22
RLSD
RR (A)
(CD)
23
GND
RR (B)
(RLSD)
24
RI
IC
25
LOS
LOS
26
DTR
Signal
dir.
RS366
X21
RS366
GND
GND
DPR
Output
ACR
Input
CRQ
Output
PND
Input
DLO
Input
NB1
Output
NB2
Output
NB4
Output
NB8
Output
T (A)
Output
T (B)
Output
R(A)
Input
R(B)
Input
S(A)
Input
S(B)
Input
Input
Input
C(A)
Output
C(B)
Output
I (A)
Input
I (B)
Input
Input
Output
Output
Call control (menu
setting)
Data
Leased
trig.
line
Manual
Frame Ground (connected
to GND)
x
Digit present
x
Abandon Call & Retry
x
Call Request
x
Present Next Digit
x
Data Line Occupied
x
Digit bit 1
x
Digit bit 2
x
Digit bit 3
x
Digit bit 4
x
x
x
Send Data / Transmit
Send Data / Transmit
x
x
x
Receive Data
x
x
x
Receive Data
x
x
x
Signal Clock Receive /
x
x
x
Receive Timing
Signal Clock Receive /
x
x
x
Receive Timing
Signal Clock Transmit /
x
x
x
Send Timing
Signal Clock Transmit /
x
x
x
Send Timing
GND
x
x
Terminal Ready / Control
x
x
Terminal Ready / Control
x
x
Received Line Signal
Detector / Carrier Detect /
Receiver Ready /
Indication
x
x
Received Line Signal
Detector / Carrier Detect /
Receiver Ready /
Indication
Ring Indicator / Incoming
x
Call
x
x
Loss Of Signal
x
x
(Data) Terminal Ready
Glossary