Setting the Clock

The System Clock uses a 24-hour clock format. For example, 8:05 AM would be entered as 0805; 1:30 PM would
be entered as 1330.
If the system is without power (both AC and battery), it cannot continue to keep time. When the panel is powered
up, the system clock must be reset. If the time needs to be reset, the "Armed" light will come ON when [*][2] is
entered to display trouble conditions. Note that the loss-of-time trouble will not be generated if the Auto-Arm and
Test Transmission times are not programmed with valid times (programming 9999 for the Auto-Arm and Test
Transmission times will disable these features; see Section [19]).
Set Auto=Arm Time
Refer to
Auto-Arm
it must be enabled and a valid time must be programmed.
The PC1 150 can be programmed to arm at the same time each day. Before the system Auto-Arms, the siren
will sound one short burst every IO seconds for a one minute period if Section [32] Light 2 is OFF. If any key
is pressed during the one minute warning period, Auto-Arming will be cancelled; the system will attempt to
Arm at the same time the next day.
To set the Auto-Arm time, enter [*][G][Master Code][2]. Then enter the Auto-Arm time in the 24-hour format
(for example, 2:30 pm would be entered as 1430).
Auto-Arm Enable /Disable
NOTE: For UL installations, the Auto-Arm feature must always be disabled.
When this feature is enabled, the system will automatically arm at the same time each day. The time
may be programmed in Section [19] or set using the [*][G][Master Code][2] Set Auto Arm Time command.
When the feature is being enabled, the keypad will sound 3 quick beeps when [5] is pressed. When the feature
is being disabled, the keypad will sound a single long tone when [5] is pressed.
Door Chime Enable /Disable
When this feature is enabled, the keypad will beep 5 times when any Delay or Instant zone is opened or closed;
the door chime will not operate with other zone definitions. Any Delay or Instant zones that are bypassed will not
chime. The door chime works only when the system is disarmed.
When the feature is being enabled, the keypad will sound 3 quick beeps when [6] is pressed. When the feature
is being disabled, the keypad will sound a single long tone when [6] is pressed.

Siren Test

Entering this command will sound the siren and turn ON all the keypad lights for 2 seconds.
Installer% Test
This feature allows system to be walk tested. When this command is entered, the siren will sound for 2 seconds
each time azone is activated. When performing awalk test, each zoneshould be tripped individually. Tocancel
the test mode, arm and then disarm the system.
NOTE: The communicator will transmit all alarms and restorals during the test mode. If this is not desired,
temporarily disable the communicator in Section [12], Light 1.