If the cable is replaced, the appliance can
also function in the following modes:
• 380-415 V 2N~
4 x 4 mm² four-core cable.
• 220-240 V 3~
4 x 4 mm² four-core cable.
• 380-415 V 3N~
5 x 2.5 mm² five-core cable.
Installation
Fixed connection
Fit the power line with an omnipolar circuit
breaker in compliance with installation
regulations.
The circuit breaker should be located near
the appliance and in an easily reachable
position.
Run the power cable in the rear
part of the unit. Make sure that it
does not come into contact with
the lower part of the hob or a built-
in oven below it.
Be careful when connecting
additional electrical appliances.
Connection cables must not come
into contact with hot cooking zones.
Testing
At the end of installation, carry out a brief
inspection test. If it fails to work, after
making sure that you have carried out the
instructions correctly, contact Technical
Support.