Robin America RGV4100 Service Manual page 57

Robin portable generator service manual
Hide thumbs Also See for RGV4100:
Table of Contents

Advertisement

(3) Check the insulation resistance between sta-
tor core and each stator lead using a Dr. Robin
generator tester in megger tester mode or a
megger tester. (Fig. 11-3)
If insulation is bad, replace stator with a new
one.
11-1-3 CHECKING ROTOR
(1) Remove rear cover and stator.
(2) Using a Dr. Robin or a circuit tester, measure
the resistance of the field coil at the terminals.
M
O
D
E
L
R
E
S
S I
T
A
N
C
E
NOTE : Because a diode is soldered to the coil
ends at the terminals, resistance may be mea-
sured only when tester probes touch the termi-
nals in one combination of polarity. Therefore, if
no resistance reading appears, try checking in
reverse polarity.
[Remedy]
If the resistance is not normal, replace rotor with
a new one.
R
G
V
2
8
0
0
R
G
V
4
1
0
Ω
Ω
1
7 .
5
1
7 .
7
Table. 11-2
( Ω )
0
R
G
V
6
1
0
0
Ω
1
6 .
0
- 54 -
Fig. 11-3
Fig. 11-4