Robin America RGV4100 Service Manual page 53

Robin portable generator service manual
Hide thumbs Also See for RGV4100:
Table of Contents

Advertisement

3 For RGV2800 and 6100 : Tighten the two bolts to fix the muffler bracket to the front cover, rear cover,
and then the two bolts for the muffler to the muffler bracket.
M8 x 20 mm bolt and washer Ass'y . . . 4 pcs. (for RGV2800 and 6100)
T
g i
h
e t
n
n i
g
o t
q r
u
e
1
8
6 .
-
2
4
5 .
N
-
m
1
9
0
-
2
5
0
k
g
c -
m
1
3
7 .
-
1
8
0 .
- t f
b l
10-3-8 FUEL TANK
(1) For RGV2600 and RGV4100 only :
Attach the fuel strainer to the bottom of the
fuel tank. Screw in the fuel strainer all the way
and return one to two turns, and then lock it
with the lock nut.
For RGV6000 only :
Attach the fuel strainer to the frame.
T
g i
h
e t
n
n i
g
o t
q r
u
e
4
9 .
-
6
9 .
N
-
m
5
0
-
7
0
k
g
c -
m
3
6 .
-
5
0 .
- t f
b l
(2) Mount the fuel tank on the frame with rubber
washers between the tank flange and the frame.
M6 x 20 mm bolt (black) . . . 4 pcs.
Rubber washer . . . 4 pcs.
NOTE : For easy tank assembly, glue the rubber
washers over the mounting holes of the
frame.
(3) Connect the rubber pipe.
First, fit the hose clamps on the rubber pipe and
connect it to the strainer and the carburetor. Then
fasten it with the hose clamps.
For RGV6100, connect the rubber pipe to the
strainer and the fuel tank in the same way.
NOTE : Apply a drop of oil to the rubber pipe for
easier connection.
- 50 -
Fig. 10-30