Robin America Subaru R1700i Instructions For Use Manual

Robin America Subaru R1700i Instructions For Use Manual

Robin generator instructions manual
Hide thumbs Also See for Subaru R1700i:

Advertisement

3ZZ9990170
アメリカ

Advertisement

Table of Contents
loading

Summary of Contents for Robin America Subaru R1700i

  • Page 1 3ZZ9990170 アメリカ...
  • Page 2 STOP CHOKE OVER LOAD PILOT LAMP STOP STOP CHOKE CHOKE STOP CHOKE...
  • Page 3: Air Index

    WARNING : The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. FEDERAL EMISSION COMPONENT DEFECT WARRANTY and CALIFORNIA EMISSION CONTROL WARRANTY are applicable to only those engines/ generators complied with EPA (Environmental Protection Agency) and CARB (California Air Resources Board) emission regulations in the U.S.A.
  • Page 4 FEDERAL EMISSIONS COMPONENT DEFECT WARRANTY EMISSIONS COMPONENT DEFECT WARRANTY COVERAGE – state of California. Fuji Heavy Industries Ltd. and Robin America Inc., Wood Dale Illinois, (herein “ROBIN AMERICA”) warrant(s) to the initial retail purchaser and each subsequent owner, that this Nonroad engine (herein “engine”) has been designed, built, and equipped to conform at the time of initial sale to all applicable regulations of the U.S.
  • Page 5: Limited Warranty

    CALIFORNIA EMISSION CONTROL WARRANTY STATEMENT YOUR WARRANTY RIGHTS AND OBLIGATIONS The California Air Resources Board and Fuji Heavy Industries Ltd. (herein “FUJI”) are pleased to explain the emission control system warranty on your 2005 and later Small Off-Road engine (herein "engine"). In California, new engine must be designed, built and equipped to meet the State's stringent anti-smog standards.
  • Page 6 When warranty repair is needed, the engine must be brought to an authorized service dealer or warranty station’s place of business during normal business hours. In all cases, a reasonable time, not to exceed 30 days, must be allowed for the warranty repair to be completed after the engine is received by the authorized service dealer or warranty station.
  • Page 7: Table Of Contents

    Thank you very much for purchasing a ROBIN GENERATOR. This manual covers operation and maintenance of the ROBIN GENERATOR. This ROBIN GENERATOR can be used for general electrical equipments, appliances, lamps, tools as an AC power source. With regards to DC application, the terminals are used only for charging 12 volt battery. Never use this generator for any other purposes.
  • Page 8: Safety Precautions

    1. SAFETY PRECAUTIONS Please make sure you review each precaution carefully. Pay special attention to statement preceded by the following words. WARNING “WARNING” indicates a strong possibility of severe personal injury or loss of life if instructions are not followed. CAUTION “CAUTION”...
  • Page 9 WARNING Do not operate in rain, in wet or damp conditions, or with wet hands. The operator may suffer severe electric shock if the generator is wet due to rain or snow. WARNING If wet, wipe and dry it well before starting. Do not pour water directly over the generator, nor wash it with water.
  • Page 10: Rated Frequency Hz

    Symbols and Meanings In accordance with the European requirements (eec Directives),the specified symbols as shown in the following table are used for the products and this instruction manual. Read the operator's instruction manual. Stay clear of the hot surface. Exhaust gas is poisonous. Do not operate in an unventilated room.
  • Page 11: Components

    2. COMPONENTS (See Fig. 1 1 ) NOTE Please refer to the illustrations on the back page of the front cover or back cover for Fig. 1 1 to 6 6 indicated in the sentence. q RECOIL STARTER (HANDLE) w CONTROL PANEL e SIDE PANEL (L) r AIR CLEANER t FUEL DRAIN SCREW...
  • Page 12: Pre-Operation Checks

    7. DC CIRCUIT BREAKER (See Fig. 2 2 -y y ) DC circuit breakers shut off electric current when the current exceeds its limit or a malfunction occurs in the connected appliance. Check for excessive current consumption or defects in the appliance. After making sure everything is in order, push the button to the "...
  • Page 13: Operating Procedures

    WARNING Make sure you review each warning in order to prevent fire hazard. Do not refill tank while engine is ■ ■ running or hot. Before filling fuel, turn the engine ■ ■ switch into " " (STOP) position. Be careful not to admit dust, dirt, water ■...
  • Page 14: Control Panel

    (e) After 20 to 30 seconds of warm-up is completed, turn the engine switch to " (f) Make sure the pilot lamp is on. This indicates that the generator is properly operating. NOTE Please consult with the nearest dealer if the pilot lamp is turned off during the proper operation.
  • Page 15: Stopping The Generator

    WARNING Be sure to ground the generator if the ■ ■ connected electrical device is grounded. Failure to ground unit could lead to ■ ■ electrical spark. CAUTION Do not put foreign objects into the plug receptacle. NOTE If the generator is stopped with the overload pilot lamp turned on, the generator will be in the overload condition and/or the electrical appliance(s) would be out of order.
  • Page 16: Wattage Information

    6. WATTAGE INFORMATION Some appliances need a "surge" of energy when starting. This means that the amount of electrical power needed to start the appliance may exceed the amount needed to maintain its use. Electrical appliances and tools normally come with a label indicating voltage, cycles / Hz, amperage (amps) and electrical power needed to run the appliance or tool.
  • Page 17: Spark Arrester

    7. SPARK ARRESTER In a dry or wooded area, it is recommendable to use the product with a spark arrester. Some areas require the use of a spark arrester. Please check your local laws and regulations before operating your product. The spark arrester must be cleaned regularly to keep it functioning as designed.
  • Page 18: Maintenance Schedule

    8. MAINTENANCE SCHEDULE MAINTENANCE, REPLACEMENT OR REPAIR OF THE EMISSION CONTROL DEVICES AND SYSTEMS MAY BE PERFORMED BY ANY NONROAD ENGINE REPAIR ESTABLISHMENT OR INDIVIDUAL. DAILY INSPECTION Before running the generator, check the following service items: PERIODIC MAINTENANCE Periodic maintenance is vital to safe and efficient operation of your generator. Check the table below for periodic maintenance intervals.
  • Page 19: [Approx.] Hours

    Periodic Maintenance Schedule table Maintenance Items Clean generator and check bolt and nuts Check and refill engine oil Change engine oil (*Note1) Clean spark plug Clean air cleaner Replace air cleaner element Clean fuel filter Clean and adjust spark plug and electrodes Replace spark plug Clean spark arrester Remove carbon from cylinder head (*Note 2)
  • Page 20: How-To" Maintenance

    9. "HOW-TO" MAINTENANCE (See Fig. 5 5 ) CAUTION Make sure the engine is stopped before starting any maintenance, servicing or repair. NOTE It is recommended to use ear protection when performing operation, maintenance and repair of the generator set. 1.
  • Page 21: Transporting

    11. TRANSPORTING When transporting the generator, make sure that the fuel (gasoline) should be drained from the tank. WARNING To prevent fuel spillage due to the ■ ■ vibration and impact, never transport the generator with the fuel (gasoline) filled in the tank. Secure the tank cap thoroughly.
  • Page 22: Troubleshooting

    13. TROUBLESHOOTING When generator engine fails to start after several attempts, or if no electricity is available at the output socket, check the following chart. If your generator still fails to start or generate electricity, contact your nearest Robin dealer or service shop for further information or corrective procedures. When Engine Fails to Start: Check if engine switch is in its proper position.
  • Page 23: Specifications

    14. SPECIFICATIONS MODEL Type AC Output Rated voltage V Rated Frequency Rated current Rated output Rated power factor Safety device ; type DC Output Rated voltage V Rated current Safety device ; type Ground system Model Type Forced air-cooled,4-cycle,single cylinder OHV type gasoline engine Displacement mL (cu.in.) Rated output kW / rpm Fuel...
  • Page 24: Wiring Diagram

    15.WIRING DIAGRAM R1700i (60Hz-120V) ENGINE STEP MOTOR IGNITION COIL PICKUP COIL Grn/Y GENERATOR Wiring color cord : Black LBlu Blk/W : Black/White : Blue Brn/W : Brown/White LED INDICATOR INVERTER & ENGINE CONTROL UNIT OIL LEVEL SENSOR MAIN COIL DC COIL Y/Blu : Light blue : Green...
  • Page 25 ISSUE EMD-GU2093 PRINTED IN JAPAN March 2005 IMPRESO EN JAPÓN Marzo 2005...