2. Features

2.1. Batterie Management System

The BMS is used to monitor, control and protect your Victron Lithium Batteries Smart. It detects the state of charge and protects
against deep discharge and overcharging.
It's main features are:
• Pre-alarm mode configurable via the programmable relay
• ATC/ATD ports to control chargers and loads
• DVCC support for compatible Victron inverter/charger and MPPTs via a connected GX device
• Discharge floor used to set the minimum SoC to determine how far the battery is allowed to be discharged. (requires
VictronConnect v5.70 or later)
A configurable pre-alarm warns with a minimum delay of 30 seconds of an imminent shutdown of the loads as a result of an
impending low cell voltage. By reacting quickly on the pre-alarm, for example by reducing the load or starting a generator to
charge the batteries, the shutting down of the loads can be prevented.
The ATC contact is opened to stop charging at high cell voltage or low temperature, while the ATD contact is opened to stop
discharging at a low cell voltage.
DVCC controls compatible devices via Lynx Smart BMS and a connected GX device. Charging current and voltages are set
automatically, thus Bulk, Absorption and Float algorithms are no longer used. Charging or discharging are stopped at low or high
cell voltage or low temperature.

2.2. Contactor

The built-in contactor serves two purposes:
1. It acts as a secondary safety system to protect the battery in case the primary controls (ATC and ATD contacts as well as
DVCC) fail to disable the loads and/or chargers when required.
2. It can be used as a remote controlled main system on/off switch via the VictronConnect app, a GX device (only Standby and
On), as well as using the Remote on/off terminals.

2.3. Built-in pre-charge circuit

The built-in pre-charge circuit pre-charges capacitive loads such as inverters or inverter/chargers before the contactor closes to
prevent high inrush current.

2.4. Battery Monitor

The Lynx Smart BMS battery monitor operates in a similar fashion as the other
shunt and battery monitor electronics. Readout of the battery monitor data is via Bluetooth using the VictronConnect App or a GX
device and the VRM portal.

2.5. Programmable relay

The Lynx Smart BMS has a programmable relay that can be used as an alarm relay (combined with the pre-alarm) or to shut
down an alternator via its external regulator (ignition wire).

2.6. AUX terminal

The Lynx Smart BMS is equipped with an auxiliary power supply. This supply outputs the same voltage as the system battery
voltage and is rated at a maximum continuous current rating of 1.1A.
The purpose of the auxiliary power supply is to keep certain systems powered, for example a GX device, after the BMS has
turned off loads in case of a low cell voltage event.
It is recommended that the system includes a GX device powered by the AUX port. This keeps the GX device
supplied with power until the AUX port is finally switched off (max. 2 hours after a low cell voltage event) to
preserve energy.