Victron energy Lynx Smart BMS 500 Manual page 39

Table of Contents

Advertisement

Menu item
Total charge cycles
Number of full discharges
Cumulative Ah drawn
Minimum voltage
Maximum voltage
Synchronisation count
Discharged energy
Charged energy
Clear history
Diagsnostics
Diagnostics
Fuses
Distributor A
Fuse 1..4
Distributor B
Fuses 1..4
IO
System switch
Allow to charge
Allow to discharge
Device
Parameters
Charge Voltage Limit (CVL)
Charge Current Limit (CCL)
Discharge Current Limit (DCL)
Page 36
Lynx Smart BMS
Default value /
Description and / or possible values
unit
0
Number of charge cycles since last history reset
0
A full discharge is accounted for after SoC falls below 5%
Ah
Cumulative Ah drawn since last history reset
V
Minimum voltage since last history reset
V
Maximum voltage since last history reset
0
Cumulative number of battery monitor synchronisations
kWh
Cumulative number of discharged energy since last history reset
kWh
Cumulative number of charged energy since last history reset
Press to clear
Clears all history data
Shows last known errors
Ok
Possible states: Ok, Fuse blown
Ok
Possible states: Ok, Not used, Blown
Ok
Possible states: Ok, Fuse blown
Ok
Possible states: Ok, Not used, Blown
Enabled
Status of the system switch
Yes
Status of the ATC signal
Yes
Status of the ATD signal
Device related parameters and custom name setting
V
Shows the voltage target send to DVCC compatible chargers (for a
12V battery: 13.50V or 14.20V)
A
Maximum allowed charge current limit send to DVCC compatible
chargers
A
Maximum allowed discharge current limit
Appendix

Advertisement

Table of Contents
loading

Table of Contents