HARDWIRING THE POWER SUPPLY PERMANENTLY TO
THE CHARGING STATION (MODEL SEV1600HW ONLY)
Turn off the power to circuit before installation. Do not restore power
until installation is complete. Failure to do so could result in injury or
death.
1.
When installing a hardwired circuit, Schumacher Electric
recommends that the AC input uses a conduit into the rear opening
of the charging station.
2. Turn off the power to the circuit before mounting the charging
station.
3. Feed the conduit and wires through the back of the charging station,
removing the back head plug. Feed the cables through the back of
the charging station until the silver conductors are no longer visible.
Note: If installing the charging station outdoors and using the back
opening to route the conduit, apply liquid sealant or a gasket and
nut around the rear opening to prevent water ingress.
4. Inside the wiring access panel, there are two terminal blocks.
Securely insert wires into the left-hand terminal block as indicated
by the wiring diagram below.
L1 - Red Wire
L2 - Black Wire
PE - Green Wire
L1
L2
PE