Description
Combination Vandal Resistant Refrigerated Drinking Fountain (Cooler) and Bottle Filling Station delivers chilled, clean potable drinking water.
Top Bottle Filling section dispenses water for bottles at the press of the top button. While the bottom Water Cooler section, which houses the
refrigeration and filtration systems, delivers a steady stream of water for direct drinking at the press of the front button.
Ratings
Electrical: 220-240 Vac, 50/60 Hz, (See nameplate for Amperage),
1phase
Ambient Air Temperature: 50-89.6°F (10-32°C)
Water Pressure: 20-105 psig (0.14-0.72 MPa)
Maximum Water Temperature: 90 °F (3 2 °C)
Sound Pressure level (A-weighted): < 70 dBA
Definitions
DANGER
– Indicates death or serious injury will result if proper precautions are not taken.
WARNING
– Indicates death, serious injury or property damage can result if proper precautions are not taken.
CAUTION
– Indicates some injury or property damage may result if proper precautions are not taken.
Authorized Service Personnel – Factory trained personnel or personnel having working knowledge of electrical, plumbing and
machine (appliance) maintenance procedures. Service personnel must have specialized training for flammable refrigerants.
Safety
DANGER
Please read these instructions completely before starting the installation or performing any service. Failure to follow the instructions
and safety precautions in this manual can result in serious injury or death.
After installation, keep these instructions in a safe location for future reference.
Electric supply must be identical in voltage, cycle, and phase to that specified on nameplate.
Electrical supply may require Ground Fault Circuit Interrupter (GFCI) protection. Consult specific application and local codes.
A means for disconnecting electrical supply to the unit must be incorporated in the fixed wiring in accordance with wiring rules. This is
to allow electrical disconnection of the unit from electrical supply after installation.
WARNING
• Keep clear of obstructing all ventilation openings in the appliance enclosure or in the structure for building-in.
• Place in a well ventilated area to prevent accumulation of refrigerant.
• No open flame or sparks during service or repair.
• For use with clean, clear potable drinking water only. Do not use with water that is microbiologically unsafe or of unknown quality without
adequate disinfection before the system.
• Installation and connection to water and electrical mains must be in compliance with local and national laws.
• All Installation and Service work must be performed by trained / authorized service personnel.
Notice: Coolers that use flammable refrigerants, such as R-600a (isobutane), R-290 (propane) will be marked with a
specific symbol that notifies the servicer of the presence of these refrigerants. A service provider should review this marking
and follow all instructions from the original equipment manufacturer.
HTHBHVR8N-NF_2A
Original Instructions
Page 1
Refrigerant: R290
Ingress Protection: IP20
For Indoor Commercial Use only
Water Inlet: 3/8"O.D. unplated copper tube
Waste Water Outlet: 1-1/4" O.D. tube
2000000552 (Rev. B - 06/22)

Advertisement

loading

Summary of Contents for Elkay HTHBHVR8-NF-25N

  • Page 1 HTHBHVR8N-NF_2A Installation / Care / Use Manual Original Instructions Model: HTHBHVR8-NF-25N Hydroboost Bottle Filling Station & Cooler Description Combination Vandal Resistant Refrigerated Drinking Fountain (Cooler) and Bottle Filling Station delivers chilled, clean potable drinking water. Top Bottle Filling section dispenses water for bottles at the press of the top button. While the bottom Water Cooler section, which houses the refrigeration and filtration systems, delivers a steady stream of water for direct drinking at the press of the front button.
  • Page 2: Installation: Electrical Connection

    HTHBHVR8N-NF_2A CAUTION • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge if they have been given supervision or instructions concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 3 HTHBHVR8N-NF_2A Page 3 2000000552 (Rev. B - 06/22)
  • Page 4 HTHBHVR8N-NF_2A MOUNTING SCREWS TOP COVER MOUNTING BRACKET FOR FASTENING UNIT BOTTLE FILLER TO WALL MOUNTING SCREW DO NOT REMOVE MOUNTING SCREW DO NOT REMOVE NOTE: TRIM PLATES MUST BE INSTALLED ON THE INSIDE OF THE BOTTLE FILLER SIDE PANEL SLOTS WATER COOLER Installation: Bottle Filler Mounting 1.
  • Page 5: Operation: Start-Up

    HTHBHVR8N-NF_2A Operation: Start-Up Turn water supply on and inspect for leaks. Fix all leaks before continuing. Connect plug-end of International Power Cord Sets from the Cooler and Bottle Filler into electrical outlets. Bottle Filler must have electrical power to dispense water. Be sure to reinstall fuse to the circuit or switch the circuit breaker back to the “ON” position. WARNING: Exposed electrically energized components.
  • Page 6: Service Adjustments

    HTHBHVR8N-NF_2A Service For proper and safe servicing, please read these instructions completely. DANGER • All Service and Maintenance must be performed by an authorized service person. Service Technician must have specialized training before servicing systems containing flammable refrigerants. Personnel who have not received certification for completing the Hydrocarbon Training Program and passed the examination, or received equivalent training and certification, do not service any system containing flammable refrigerants.
  • Page 7: Replacement Parts

    HTHBHVR8N-NF_2A Replacement Parts Description Part No. Kit - Aerator Replacement 98546C Kit - Hardware & Waterway Parts 98549C 98631C Kit - Electrical Package 220V 1000004771 Kit - Solenoid Valve Replacement 220V 98999C Kit - Drain Pad 99000C Kit - Button Assembly Kit - Top Cover Replacement 1000001907 Kit - Gasket VR BF Tower/Basin...