Combination Refrigerated Drinking Fountain (Cooler) and Bottle Filling Station delivers chilled, clean potable drinking water. Top Bottle Filling
section offers touchless activation to dispense water for bottles. While the bottom Water Cooler section, which houses the refrigeration and
filtration systems, delivers a steady stream of water for direct drinking at the press of front and sidebars.
Ratings
• Electrical: 220-240 Vac, 50/60 Hz, (See Nameplate for Amperage),
1 phase
• Ambient Air Temperature: 50-89.6 °F (10-32 °C)
• Water Pressure: 20-105 psig (0.14-0.72 MPa)
• Maximum Water Temperature: 90 °F (32 °C)
• Sound Pressure level (A-weighted): < 70 dBA
Definitions
DANGER
– Indicates death or serious injury will result if proper precautions are not taken.
WARNING
– Indicates death, serious injury or property damage can result if proper precautions are not taken.
CAUTION
– Indicates some injury or property damage may result if proper precautions are not taken.
Authorized Service Personnel – Factory trained personnel or personnel having working knowledge of electrical, plumbing, and
machine (appliance) maintenance procedures. Service personnel must have specialized training for flammable refrigerants.
Safety
DANGER
• Please read these instructions completely before starting the installation or performing any service. Failure to follow the instructions and
safety precautions in this manual can result in serious injury or death.
• After installation, keep these instructions in a safe location for future reference.
• Electric supply must be identical in voltage, cycle, and phase to that specified on nameplate.
• Electrical supply may require Ground Fault Circuit Interrupter (GFCI) protection. Consult specific application and local codes.
• A means for disconnecting electrical supply to the unit must be incorporated in the fixed wiring in accordance with wiring rules. This is to allow
electrical disconnection of the unit from electrical supply after installation.
WARNING
• Keep clear of obstructing all ventilation openings in the appliance enclosure or in the structure for building-in.
• Place in a well ventilated area to prevent accumulation of refrigerant.
• No open flame or sparks during service or repair.
• For use with clean, clear potable drinking water only. Do not use with water that is microbiologically unsafe or of unknown quality without
adequate disinfection before the system.
• Installation and connection to water and electrical mains must be in compliance with local and national laws.
• All Installation and Service work must be performed by trained / authorized service personnel.
Notice: Coolers that use flammable refrigerants, such as R-600a (isobutane), R-290 (propane) will be marked with a
specific symbol that notifies the servicer of the presence of these refrigerants. A service provider should review this marking
and follow all instructions from the original equipment manufacturer.
HBHAC8WF_2AWN
Original Instructions
Model:HTHBHAC8SSWF25WN
Page 1
• Ingress Protection: IP20
• For Indoor Commercial Use only
• Water Inlet: 3/8" (9.5mm) O.D. unplated copper tube
• Waste Water Outlet: 1-1/4" (38.1mm) O.D. tube
• Refrigerant : R290
2000000553 (Rev. B - 06/22)

Advertisement

loading

Summary of Contents for Elkay HTHBHAC8SSWF25WN

  • Page 1 HBHAC8WF_2AWN Installation / Care / Use Manual Original Instructions Model:HTHBHAC8SSWF25WN Description Combination Refrigerated Drinking Fountain (Cooler) and Bottle Filling Station delivers chilled, clean potable drinking water. Top Bottle Filling section offers touchless activation to dispense water for bottles. While the bottom Water Cooler section, which houses the refrigeration and filtration systems, delivers a steady stream of water for direct drinking at the press of front and sidebars.
  • Page 2 HBHAC8WF_2AWN CAUTION • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge if they have been given supervision or instructions concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 3 HBHAC8WF_2AWN LEGEND A) Note: Water flow direction. B) Adjust this screw to eliminate mechanism “Free Play” or continuous flow from bubbler conditions. (See ADJUSTMENT PROCEDURE) C) Stream height adjustment. Water Valve Mechanism - ADJUSTMENT PROCEDURE: - Turn adjustment screw “Counter-Clockwise” until water flow from bubbler starts. - Turn adjustment screw “Clockwise”...
  • Page 4 HBHAC8WF_2AWN Figure 5 2000000553 (Rev. B - 06/22) Page 4...
  • Page 5: Installation

    HBHAC8WF_2AWN Installation For correct and safe installation, please read these instructions completely. DANGER • All Installation work must be performed by an authorized service person. • Disconnect electrical supply serving the Installation area to reduce risk of electrocution. Do not puncture the refrigerant tube. •...
  • Page 6 HBHAC8WF_2AWN MOUNTING SCREWS 7/16” BOLT HOLES FOR FASTENING UNIT TO WALL TOP COVER UNIT CENTER LINE Fig. 7 Figure 6 Figure 7 BRACKET, WASHERS, Figure 9 Figure 8 & SCREWS Installation: Bottle Filler 1. Remove two (2) mounting screws with 5/32” (4mm) Allen wrench holding top cover to Bottle Filler (See Fig. 7). Remove top cover. Note do not discard mounting screws, they will be needed to reinstall top cover.
  • Page 7: Wall Mounting Plate

    HBHAC8WF_2AWN Installation: Bottle Filler (Continued) 13. Turn water supply on and inspect for leaks. Fix all leaks before continuing. 14. Once unit has been inspected for leaks and any leaks found corrected, plug Bottle Filler and unit into wall. Be sure to reinstall fuse to the circuit or switch the circuit breaker back to the “ON”...
  • Page 8 HBHAC8WF_2AWN Installation: Start Up (Also see general instructions) 1. Stream height is factory set for 45-50 PSI supply. If supply pressure varies greatly from this, readjust stream height to approximately 1-1/2” (38mm) above the bubbler guard by turning adjustment screw, accessible by removing front push panel (see Fig. 2 & 4). 2.
  • Page 9 HBHAC8WF_2AWN BF12 Program: Setting the Control Board Verify Control Board Software 1. To verify the software program of the control board the unit will need to be shut down and restarted. The chiller (if present) does not need to be shut down and restarted. 2.
  • Page 10 HBHAC8WF_2AWN BF12 Program: Setting the Control Board (continued) Resetting the Bottle Count NOTE: Once the bottle count is reset to zero there is no way to return to the previous bottle count. 1. Depress the program button for approximately 2 seconds until the display changes then release. The display will change and scroll through two messages: •...
  • Page 11: Parts List

    HBHAC8WF_2AWN PARTS LIST BOTTLE FILLER REPLACEMENT PART LIST ITEM NO. PART NO. DESCRIPTION ITEM NO. PART NO. DESCRIPTION 22897C Panel - Bottom Dispenser N.S. 98631C Kit - Electrical Package 220V 23003C Bracket - Regulator Mounting N.S. 98544C Kit - IR Sensor 220V 28551C Hanger Bracket N.S.