Combination Refrigerated Drinking Fountain (Cooler) and Bottle Filling Station delivers chilled, clean potable drinking water. Top Bottle Filling
section offer touchless activation to dispense water for bottles. While the bottom Water Cooler section, which houses the refrigeration and
filtration systems, delivers a steady stream of water for direct drinking at the press of front and sidebars.
Ratings
• Electrical: 220Vac, 50Hz, (See Nameplate for Amperage), 1 phase.
• Ambient Air Temperature: 50-100.4 °F (10-38 °C).
• Water Pressure: 20-100 psig (0.14-0.69 MPa).
• Maximum Water Temperature: 90 °F (32 °C).
• Ingress Protection: IP2x
Definitions
DANGER
– Indicates death or serious injury will result if proper precautions are not taken.
WARNING
– Indicates death, serious injury or property damage can result if proper precautions are not taken.
CAUTION
– Indicates some injury or property damage may result if proper precautions are not taken.
Authorized Service Personnel – Factory trained personnel or personnel having working knowledge of electrical,
plumbing, and machine (appliance) maintenance procedures.
Safety
DANGER
• Please read these instructions completely before starting the installation or performing any service. Failure to follow the instructions and safety
precautions in this manual can result in serious injury or death.
• After installation, keep these instructions in a safe location for future reference.
• Electric supply must be identical in voltage, cycle, and phase to that specified on nameplate.
• Electrical supply must have Ground Fault Circuit Interrupter (GFCI) protection.
• A means for disconnecting electrical supply to the unit must be incorporated in the fixed wiring in accordance with wiring rules. This is to allow
electrical disconnection of the unit from electrical supply after installation.
WARNING
• For use with clean, clear potable drinking water only. Do not use with water that is microbiologically unsafe or of unknown quality without
adequate disinfection before the system.
• Installation and connection to water and electrical mains must be in compliance with local and national laws.
• All Installation and Service work must be performed by an authorized service personnel.
CAUTION
• This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory, or mental capabilities
or lack of experience and knowledge if they have been given supervision or instructions concerning use of the appliance in a safe way and
understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children
without supervision.
• To prevent a metallic taste or increased metal content in the water due to an electrolysis process caused by electrical feedback from the
grounding of electrical equipment to water supply and water waste mains, connect to these mains using non-conductive materials. The provided
solenoid valve regulator assembly meets this requirement.
HAC8FSCWSQ_1FWR, HAC-HB_1BWR
Installation / Use Manual
Original Instructions
Model: HTHB-HAC8SS-WF-25WR
• For Indoor Commercial Use only.
• Water Inlet: 3/8" (9.5mm) O.D. unplated copper tube.
• Waste Water Outlet: 1-1/4" (38.1mm) O.D. tube.
Page 1
1000004158 (Rev. C - 04/18)

Advertisement

loading
Need help?

Need help?

Do you have a question about the HTHB-HAC8SS-WF-25WR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Elkay HTHB-HAC8SS-WF-25WR

  • Page 1 HAC8FSCWSQ_1FWR, HAC-HB_1BWR Installation / Use Manual Original Instructions Model: HTHB-HAC8SS-WF-25WR Description Combination Refrigerated Drinking Fountain (Cooler) and Bottle Filling Station delivers chilled, clean potable drinking water. Top Bottle Filling section offer touchless activation to dispense water for bottles. While the bottom Water Cooler section, which houses the refrigeration and filtration systems, delivers a steady stream of water for direct drinking at the press of front and sidebars.
  • Page 2 HAC8FSCWSQ_1FWR, HAC-HB_1BWR See Fig. 2 for Push Bar Mechanism Figure 1 1000004158 (Rev. C - 04/18) Page 2...
  • Page 3 HAC8FSCWSQ_1FWR, HAC-HB_1BWR LEGEND A) Note: Water flow direction. B) Adjust this screw to eliminate mechanism “Free Play” or continuous flow from bubbler conditions. (See ADJUSTMENT PROCEDURE) C) Stream height adjustment. 25 B Water Valve Mechanism - ADJUSTMENT PROCEDURE: - Turn adjustment screw “Counter-Clockwise” until water flow from bubbler starts. - Turn adjustment screw “Clockwise”...
  • Page 4 HAC8FSCWSQ_1FWR, HAC-HB_1BWR Figure 5 1000004158 (Rev. C - 04/18) Page 4...
  • Page 5: Installation

    HAC8FSCWSQ_1FWR, HAC-HB_1BWR Installation For correct and safe installation, please read these instructions completely. DANGER • All Installation work must be performed by an authorized service personnel. • Disconnect electrical supply serving the Installation area to reduce risk of electrocution. • Unit not suitable for installations where water jets could be used. WARNING •...
  • Page 6 HAC8FSCWSQ_1FWR, HAC-HB_1BWR MOUNTING 7/16” BOLT HOLES FOR SCREWS FASTENING UNIT TO WALL TOP COVER UNIT CENTER LINE Fig. 7 Figure 8 Figure 9 BRACKET & SCREWS Figure 10 Figure 11 Installation: Bottle Filler 1. Remove two (2) mounting screws with 5/32” Allen wrench holding top cover to Bottle Filler (See Fig. 9). Remove top cover. Note do not discard mounting screws, they will be needed to reinstall top cover.
  • Page 7: Wall Mounting Plate

    HAC8FSCWSQ_1FWR, HAC-HB_1BWR Installation: Bottle Filler (Continued) 13. Turn water supply on and inspect for leaks. Fix all leaks before continuing. 14. Once unit has been inspected for leaks and any leaks found corrected, plug Bottle Filler and unit into wall. Be sure to reinstall fuse to the circuit or switch the circuit breaker back to the “ON”...
  • Page 8 Assy-Filter & Bracket includes Fltr Head/Mtg Bkt/ John Guest Ftgs/Screws For Replacement Parts, contact your local distributor or call 1.800.834.4816 Elkay Manufacturing Co. 2222 Camden Court Oak Brook, IL 60523 U.S.A – 630.574.8484 1000004158 (Rev. C - 04/18) Page 8...
  • Page 9 HAC8FSCWSQ_1FWR, HAC-HB_1BWR BF11-BF12 Program: Setting the Control Board Verify Control Board Software 1. To verify the software program of the control board the unit will need to be shut down and restarted. The chiller (if present) does not need to be shut down and restarted.
  • Page 10 HAC8FSCWSQ_1FWR, HAC-HB_1BWR BF11 Program: Setting the Control Board (continued) Resetting the Bottle Count 1. Depress the program button for approximately 2 seconds until the display changes then release. The display will change and scroll through two messages: • RST FLTR – Reset Filter Status LED •...
  • Page 11: Parts List

    HAC8FSCWSQ_1FWR, HAC-HB_1BWR PARTS LIST BOTTLE FILLER REPLACEMENT PART LIST ITEM NO. PART NO. DESCRIPTION ITEM NO. PART NO. DESCRIPTION N.S. 98631C Kit - Electrical Package 220V 22897C Panel - Bottom Dispenser N.S. 98544C Kit - IR Sensor 220V 23003C Bracket - Regulator Mounting N.S.