Installation/Care/Use Manual
®
Soft Sides
Installer
To assure you install this model easily and correctly, PLEASE READ
THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLA-
TION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH
PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After
installation, leave these instructions inside the fountain for future reference.
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE
BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELEC-
TROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER.
THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS
PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN
FROM THE BUILDING PLUMBING SYSTEM.
3/8" O.D. UNPLATED
1/4" O.D. TUBE
COPPER TUBE CONNECT
WATER INLET
COLD WATER SUPPLY
TO COOLER
NOTE: WATER FLOW
FIG. 1
DIRECTION
3
4
17
11
18
ERFP8C*C
ERFPVR8C*A
Refrigerated Fountains with FLEXI-GUARD
ERFP8C
IMPORTANT
BUILDING WATER
INLET
SERVICE STOP
(NOT FURNISHED)
10
2
5
FIG. 3
PAGE 1
LNFE8C*C
FIG. 2
NOTE: WHEN INSTALLING
REPLACEMENT BUBBLER
AND PEDESTAL, TIGHTEN
7
NUT (ITEM 9 OR 30) ONLY
TO HOLD PARTS SNUG IN
POSITION. DO NOT
6
8
OVER TIGHTEN.
9
FIG. 4
®
32
31
30
FIG. 5
97869C (Rev. K - 1/12)

Advertisement

loading

Summary of Contents for Elkay Soft Sides ERFP8C C Series

  • Page 1 ERFP8C*C ERFPVR8C*A LNFE8C*C Installation/Care/Use Manual ® ® Soft Sides Refrigerated Fountains with FLEXI-GUARD ERFP8C Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLA- TION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES.
  • Page 2 ERFP8C*C ERFPVR8C*A LNFE8C*C MODEL LNFE8C LEGEND A = 1/4" O.D. TUBE CONNECT (CHILLER WATER OUTLET) B = 3/8" O.D. TUBE CONNECT (CHILLER WATER INLET) SHUT OFF VALVE BY OTHERS C = 1-1/4" TRAP FURNISHED D = ELECTRICAL INLET FIG. 6 97869C (Rev.
  • Page 3 ERFP8C*C ERFPVR8C*A LNFE8C*C INSTALLATION INSTRUCTIONS 1. Install remote chiller. Remove front panel of chiller. Remove and discard cardboard inner pack from between compressor and side panel. Slide chiller onto the shelf and position it to the left within the guides on the shelf. NOTE: Building construction must allow for adequate air flow on both sides, top, and back of chiller.
  • Page 4 FIG. 12 FIG. 13 REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640 FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620 ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 97869C (Rev. K - 1/12) PAGE 4...

This manual is also suitable for:

Soft sides erfpvr8c a seriesSoft sides lnfe8c c seriesSoft sides erfp8cSoft sides lnfe8c