Download Print this page
Hide thumbs Also See for GigaVUE-TA100-CXP:

Advertisement

Quick Links

GigaVUE-TA100-CXP
Hardware
Installation Guide
(EOS)
GigaVUE TA Series
Product Version: 5.16
Document Version: 1.0
(See Change Notes for document updates.)

Advertisement

loading
Need help?

Need help?

Do you have a question about the GigaVUE-TA100-CXP and is the answer not in the manual?

Questions and answers

Summary of Contents for Gigamon GigaVUE-TA100-CXP

  • Page 1 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) GigaVUE TA Series Product Version: 5.16 Document Version: 1.0 (See Change Notes for document updates.)
  • Page 2 Gigamon Inc.. Trademark Attributions Gigamon and the Gigamon logo are trademarks of Gigamon in the United States and/or other countries. Gigamon trademarks can be found at www.gigamon.com/legal- trademarks.
  • Page 3 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Change Notes When a document is updated, the document version number on the cover page will indicate a new version and will provide a link to this Change Notes table, which will describe the updates.
  • Page 4 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Contents GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Change Notes Contents About the GigaVUE TA Series Family GigaVUE TA Series Overview GigaVUE TA Series Nodes GigaVUE TA Series Features and Benefits Standard H Series Features GigaVUE-TA100-CXPChassis Chassis Cooling...
  • Page 5 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Basic Connections and Configuration Grounding the GigaVUE TA Series TA Series Chassis Avoid Electrostatic Damage! Connecting Power to the GigaVUE TA Series TA Series Connecting -48V DC Power Supplies Cautions for Power and Ground connections Précautions relatives au raccordement à l’alimentation et à la terre Warning: Fiber Optic Port Safety Avertissement : Sécurité...
  • Page 6 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) MTP/APC 12 Position Fiber Cable for Use with QSFP+ PLR4 Transceivers MPO/MTP 24 Position Fiber Cable for Use with SR10 Transceivers GigaVUE TA Series TA Series Specifications Physical Dimensions and Weight Power Requirements Fan Tray Specification for GigaVUE-TA100 and TA100-CXP...
  • Page 7 About the GigaVUE TA Series Family Gigamon’s TA Series and H Series of the Gigamon Visibility and Analytics Fabric nodes deliver unprecedented switching capacity, port density, and from 1Gb up to 100Gb support. The GigaVUE H Series and GigaVUE TA Series include the following models that...
  • Page 8 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) : The GigaVUE TA Series support network, tool, clustering, and stack port MPORTANT connections to other GigaVUE TA Series nodes, including both GigaVUE H Series nodes or G Series (for example, a GigaVUE TA Series-2404 node, a GigaVUE TA Series-HD8 node).
  • Page 9 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) GigaVUE-TA40 ■ GigaVUE-TA100 ■ GigaVUE-TA100-CXP ■ GigaVUE-TA200 ■ GigaVUE-TA400 ■ GigaVUE-TA10 1RU Footprint ■ 48 1Gb/10Gb ports ■ 4 40Gb ports ■ Optional patch or breakout ■ panel support Cluster with H Series nodes ■...
  • Page 10 Depending on the model, the GigaVUE TA Series supports a wide variety of ■ Gigamon® transceivers. Transceivers purchased from other vendors are not supported. Optional patch panel or breakout panel allows use of 40Gb ports as four individual ■...
  • Page 11 7 rear hot swappable fan modules, console port and a 10M/100M/1G management port. The GigaVUE TA Seriesnodes make it easy to leverage the system’s 10Gb or 40Gb port density, aggregating multiple underused 40Gb/10Gb/1Gb network ports to 40Gb/10Gb tool ports for uplink to the Gigamon Visibility Platform. Contents...
  • Page 12 10Gb ports, called 4x10G mode. The QSFP28 and CXP ports on GigaVUE-TA100-CXP can be used as network, tool, or hybrid ports. They cannot be used as stack ports. Subports created from 4x10G mode can function as network, tool, or hybrid ports.
  • Page 13 The GigaVUE-TA100-CXPChassis Front View Table 1: GigaVUE-TA100-CXPPorts Port Description Mgmt Use the Mgmt port for remote configuration of the GigaVUE-TA100-CXP over a 10/100/1000 Ethernet network. Console Use the console port for local configuration of the GigaVUE-TA100-CXP over a serial connection. Contents...
  • Page 14 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Port Description Use the USB port to upgrade software on the GigaVUE-TA100-CXP using a software image on an external USB drive. Refer to Software Upgrade using USB Drive. Ports c1..c20, GigaVUE-TA100-CXP includes twenty-eight (28) 100Gb ports (c1..c28). Twenty (20) c21..c28...
  • Page 15 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Chassis Cooling The fans on the GigaVUE TA Series-TA100-CXP run at 100% of their maximum speed on power up, then drop to approximately 60% during normal operations. The temperatures of four components: transceivers, exhaust, CPU, and switch CPU, are monitored. When a component crosses a pre-defined threshold, the fan speed is adjusted dynamically, in increments of approximately 10%.
  • Page 16 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) The output of the following CLI command displays the fan speed in RPM (the normal operational speed is approximately 12000 RPM; the maximum speed is approximately 19000 RPM): (config) show environment Fan tray 1 (FAN-TAC00): 1st fan :...
  • Page 17 For details about the supported transceiver, cable type, and connectivity specifications, refer to “GigaVUE-OS Compatibility and Interoperability Matrix”. Network, Tool, or The QSFP28 and CXP ports on GigaVUE-TA100-CXP can be used as network, tool, or hybrid ports. Hybrid Ports Map Rules and Port The GigaVUE-TA100-CXP supports 256 map rules per chassis and 20 egress port filters per chassis.
  • Page 18 CLI command with the usb parameter. Air Flow Direction The air flow direction is from the front of the GigaVUE-TA100-CXP chassis to the rear. The rear-mounted fans pull air from the front to the back of the chassis. Install the chassis so the intake air at the front of the chassis is cold.
  • Page 19 The breakout modes for GigaVUE TA Series can be either in card mode or port mode. GigaVUE-TA10 allows card breakout mode whereas GigaVUE-TA25, GigaVUE-TA40, GigaVUE-TA100, GigaVUE-TA100-CXP, GigaVUE-TA200 and GigaVUE-TA400 allows port breakout mode. Refer to Configure the Card Mode – 40Gb/10Gb Support...
  • Page 20 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) The settings for each available mode are summarized in Table 3: 40Gb Port Settings by Card Mode on GigaVUE TA Series-TA10: Table 3: 40Gb Port Settings by Card Mode on GigaVUE TA Series-TA10 Card Physical 40Gb Interface on GigaVUE TA Series-TA10...
  • Page 21 The maximum number of 10Gb subports on a GigaVUE-TA100 is 128 (32 x 4). ■ The maximum number of 10Gb subports on a GigaVUE-TA100-CXP is 32 (8 x 4). ■ The maximum number of 10G subports on a GigaVUE-TA200 is 128 (32 x 4).
  • Page 22 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Breakout Panels Breakout panels let you connect ports on a GigaVUE TA Series node to a tool or network port or TAP for port breakout or aggregation. The following breakout panels are available: PNL-M341/PNL-M341T ■...
  • Page 23 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Figure 3 Getting Started Unpacking the GigaVUE TA Series Traffic Aggregator Unpack the GigaVUE TA Series Traffic Aggregator and inspect the box it was shipped in. If the carton was damaged, please file a claim with the carrier who delivered it.
  • Page 24 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Next, select a suitable location for the rack unit that will hold the GigaVUE TA Series Traffic Aggregation node. Choose a location that is clean, dust free, and well ventilated. You will need access to a grounded power outlet. Avoid areas where heat, electrical wire, and electromagnetic fields are generated.
  • Page 25 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Figure 4 GigaVUE TA Series Traffic Aggregator Rack Ears in Front-Mount Position To mount the GigaVUE TA Series Traffic Aggregation node in a rack: Attach the orange rack ears to the front or rear of the unit (rear mounting does not apply to GigaVUE TA Series-TA200 GigaVUE-TA25 and GigaVUE-TA400) using the supplied screws.
  • Page 26 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Four-Post Rack Methods: GigaVUE TA Series Traffic Aggregation nodes also come with a pair of full length mounting rails. These rails can be used for four point mounting on four-post racks. The keyhole rivets on the sides of each node can be used to adjust the fit of the node to the desired position or dimension on the rack.
  • Page 27 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Figure 6 Front View of the Mounted Node to the Four-Post Rack 2. Slide in the provided rails on to the node. The position of the rails can be adjusted to fit the dimensions of the rack by sliding over the rivets and placing them securely over the rivets once set in the desired position.
  • Page 28 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Figure 7 Rear View of the Mounted Node and Rails on the Four-Post Rack 3. Last, tighten the rails to the rear posts using the supplied screws. Basic Connections and Configuration This chapter describes how to establish your first configuration session with the GigaVUE TA Series Traffic Aggregator and set the basic initial configuration options necessary to get you up and running.
  • Page 29 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Grounding the GigaVUE TA Series TA Series Chassis Locate the grounding holes at the rear of the chassis. Refer to Grounding the GigaVUE TA Series TA Series Chassis Figure 9Ground Screws (GigaVUE TA Series- TA200 Shown). Figure 8...
  • Page 30 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Always use an ESD-preventive wrist or ankle strap and ensure that it makes good ■ skin contact. The strap can be connected to one of the following: Captive installation screws on chassis. Any unpainted surface on the chassis.
  • Page 31 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Figure 12 Connecting AC Power on a GigaVUE TA Series-TA200 2. Plug the other end of the power cable(s) into a power source that can supply adequate power. : If you are using the optional second power supply provided with the node, plug the two power supplies into separate circuits for optimal power protection.
  • Page 32 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Figure 13 Connecting -48V DC Power Cable Adapter Plug the DC power cable adapter into the DC power supply. For screw terminal DC power supply, use ring terminal. This is not applicable for GigaVUE-TA400. : Terminal block supports 10AWG.
  • Page 33 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Cautions for Power and Ground connections Caution : Class I Equipment. The GigaVUE TA Series equipment must be earthed. The power plug must be connected to a properly wired earth ground socket outlet. An improperly wired socket outlet could place hazardous voltages on accessible metal parts.
  • Page 34 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Caution: When installing DC Power to GigaVUE-TA400, a Skilled Person is needed to connect the Power. Cable Suggestion to use VW-1, 600V, 105 degree C, tightening torque : 13.88/1.57 (lb- in/N.m), Wire Range : 8-18AWG, Wire Type: CU's power cable(wire).
  • Page 35 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Attention : POUR RETIRER COMPLÈTEMENT L’ALIMENTATION DE L’APPAREIL AFIN D’ÉVITER UN « RISQUE DE DÉCHARGE », COUPEZ D’ABORD L’ALIMENTATION, PUIS RETIREZ LES CÂBLES ÉLECTRIQUES Attention : L'isolement du conducteur de terre de protection doit être vert et jaune.
  • Page 36 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Figure 14 Replacing a Fan (GigaVUE TA Series-TA10 Shown) 2. Push lever towards handle. 3. Pull on handle to remove the fan from the slot. To insert a fan: Place fan in empty slot. 2. Use handle to slide fan into slot.
  • Page 37 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Figure 15 Connecting the Console and Management Ports 3. Connect the DB9 end of the console cable to a PC’s COM port. 4. Connect a standard Ethernet cable (Cat5 or better) to the 10/100/1000 Mgmt port.
  • Page 38 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) 4. Configure the port settings for the console connection as follows: Bits per second – 115,200 Data bits – 8 Parity – None Stop bits – 1 Flow control – None : On the GigaVUE TA Series-TA10 and GigaVUE TA Series-TA40, you can change the console port’s speed if you need to by using the procedure in...
  • Page 39 ■ console port speed. Run the Jump-Start Script Gigamon provides the GigaVUE TA Series nodes with a jump-start script that walks you through the process of configuring basic settings. Run this script as follows: Switch to Config mode. There are three command entry modes, each with increasingly powerful rights –...
  • Page 40 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) : If you change your mind about a particular setting, you’ll have a chance to change it at the end of the script. The hostname appears in the system prompt and Hostname is used to identify the chassis in SNMP traps.
  • Page 41 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Enable cluster support if this node will be a part of Cluster Enable? a cluster of connected GigaVUE TA Series nodes. If you enable cluster support, the jump-start script prompts you to supply the Cluster ID, Cluster Name, and Cluster Mgmt Virtual IP Address.
  • Page 42 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Port Licensing GigaVUE TA Series-TA10, GigaVUE TA Series-TA40, GigaVUE TA Series-100-CXP and GigaVUE-TA25 have all ports enabled. Additional ports are available through licenses for the following GigaVUE TA Series products: GigaVUE TA Series-TA10A ■ GigaVUE TA Series-TA100 ■...
  • Page 43 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) GigaVUE-TA25A product code is 132-00FK and the GigaVUE-TA25 product code is 132- 00FJ. A license is needed to expand the GigaVUE-TA25A to include all 48 25Gb/10Gb/1Gb ports as well as the eight 100Gb /40GbUse the following CLI command to display the...
  • Page 44 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) 3. Reset the terminal settings to match the current window with the following command: terminal resize 4. Use the port command with the admin argument to enable ports. For example, the following two commands enable all available ports on a fully licensed GigaVUE TA Series-TA10A: (config) # port 1/1/q1..q4 params admin enable(config) # port 1/1/x24..x48 params admin...
  • Page 45 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Figure 17 GigaVUE-OS Command-Line Modes Entering Commands in the CLI The GigaVUE TA Series CLI provides several conventions that make it easy to identify available commands and enter them quickly: Technique Description Context-Sensitive The ? symbol is the key to receiving help wherever you...
  • Page 46 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Technique Description entered so far. For example, if you typed i? in Configure mode, the CLI would return the following possible commands based on what you’ve entered so far: image interface ip Command Help – Type a command ■...
  • Page 47 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Successful commands return no response in the CLI; commands with errors return ■ an error response beginning with %, followed by a short error description. All commands are case-sensitive and entered in lower case. ■...
  • Page 48 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Figure 18 Viewing Paging Options The Basic Commands The following table lists each of the top level commands for the GigaVUE-OS CLI in Configure mode. Most commands have multiple supported arguments. You can see the exact arguments available at any point of command entry by typing it into the CLI followed by ?.
  • Page 49 Description Manage X.509 certificates for the node’s Web server. crypto debug Generate a dump file for use in debugging issues with Gigamon Technical Support. disable Leave Enable mode and return to Standard mode. email Configure email and event notification via email.
  • Page 50 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Command Description ping6 Send ICMPv6 echo requests to a specified host. Configures an active visibility policy. policy port Configure port type, parameters, and filters. Create a group of ports. port-group port-pair Configure a port-pair on a pair of network ports within the same node. A port-pair is a bidirectional connection in which traffic arriving on one port in the pair is transmitted out the other (and vice-versa) as a passthrough TAP.
  • Page 51 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) There are a few more steps you should perform to complete the initial configuration before you set up network ports, tool ports, and aggregate traffic. These tasks include: Switch to the Configure mode.Refer to Enter the Configure Command-Line Mode.
  • Page 52 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Command Notes Enable: When SSH2 is enabled, you can use any compliant SSH2 client to connect to the command-line interface remotely. For example, to (config) # ssh server enable connect using the SSH2 client, PuTTY:...
  • Page 53 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) ssh server host-key <rsa1 | rsa2 |dsa2> <private-key | public-key> generate For example, to configure a new RSAv1 public hostkey, you could use the following command: (config) # ssh server host-key rsa1 public-key generate Initial User Account Configuration Before you start mapping traffic, you must change the password for the admin account and add a few other accounts for use by different level users.
  • Page 54 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Command Comments (config) # username Creates a new account named psandoval with a psandoval password password and grants it admin privileges. Nine9.Eight8! (config) # username psandoval roles add admin (config) # username Creates a new account named bcrawford with a bcrawford password password.
  • Page 55 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Method CLI Command For more information: System Clock clock set hh:mm:ss yyyy/mm/dd Setting Time Manually One-Time NTP ntpdate <ntpserver address> Performing One-Time NTP Server Synchronization Synchronization Persistent NTP Add server using ntp server Using NTP Time Server for System Synchronization command.
  • Page 56 Configuration). Figure 20 Checking NTP Status and Configuration Enabling the Web Server GigaVUE-FM is Gigamon’s Web-based management interface for the GigaVUE-OS, including the GigaVUE TA Series TA Series nodes. You can use GigaVUE-FM for many system configuration, management, and operations tasks.
  • Page 57 Depending on the browser you are using, you can avoid these warnings either by installing a certificate or adding an exception. : Gigamon provides the nodes with self-signed certificates for use with GigaVUE-FM; you can also create and install a third-party certificate on these nodes.
  • Page 58 The GigaVUE TA Series nodes provide powerful email notification capabilities, automatically sending emails to specified addresses when any of a wide variety of events take place on the system. Gigamon strongly recommends that you configure this feature so you have immediate visibility of events affecting system health.
  • Page 59 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Description Command First, use the email (config) # email mailhub smtp.emailsrvr.com mailhub command to specify the mail server to use for notification emails. In this example, the email server named smtp.emailsrvr.com is used. IP address can be used instead of a hostname.
  • Page 60 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Description Command sure emails are sent successfully. You can do that with the email send- test command. If you do not receive the email, check the show log output to make sure the email was sent. Then, reconfigure email settings, if necessary.
  • Page 61 Transceiver—Rules and Notes Keep in mind the following rules and notes when you connect and use GigaVUE TA Series nodes with transceivers: Always use transceivers purchased from Gigamon to ensure interoperability and ■ performance. Gigamon does not support transceivers purchased from other vendors.
  • Page 62 Gigamon stack protocol. Transceiver Installation Instructions Gigamon transceivers are keyed and can only be installed in one direction. Transceivers are hot-swappable – they can be installed or removed with the power on or off. Use the following procedures to install and remove SFPs from GigaVUE TA Series node.
  • Page 63 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Removing Transceivers Disconnect the cable (if any) from the transceiver. 2. If you are removing a fiber-optic transceiver, install dust caps in the transceiver to protect the optical interfaces. 3. Open the latch on the transceiver and gently remove it from the slot.
  • Page 64 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) MTP/APC 12 Position Fiber Cable for Use with QSFP+ PLR4 Transceivers The MTP cable is a high performance MPO connector. This is a female to female Angled Polished Connector (APC) of cable type B with an 8-degree angled end-face and a diameter of 9/125µm.
  • Page 65 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Figure 23 MPO/MTP 24 Position Fiber Cable GigaVUE TA Series TA Series Specifications This section provides the physical specifications, power requirements and environmental specifications for the GigaVUE TA Series Traffic Aggregation nodes, GigaVUE TA Series- TA10, GigaVUE TA Series-TA40, GigaVUE TA Series-TA100, GigaVUE TA Series-TA100-CXP, GigaVUE TA Series-TA200, GigaVUE-TA25 and GigaVUE-TA400.
  • Page 66 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Physical Dimensions and Weight The following table summarizes the dimensions for the GigaVUE TA Series Traffic Aggregation nodes, GigaVUE TA Series-TA10, GigaVUE TA Series-TA40, GigaVUE TA Series-TA100, GigaVUE TA Series-TA100-CXP, GigaVUE TA Series-TA200 GigaVUE-TA25 and GigaVUE-TA400:...
  • Page 67 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Power Requirements Each GigaVUE TA Series node come standard with dual, load sharing power supplies. Table 4: Power Requirements for GigaVUE TA Series-TA10 GigaVUE-TA100and TA100- CXP Fan Tray Specifications summarize the electrical characteristics for the GigaVUE TA...
  • Page 68 Max PSM Input Current (Steady State): 40A@ 48V DC Supply Modules Fan Tray Specification for GigaVUE-TA100 and TA100-CXP The GigaVUE-TA100 and GigaVUE-TA100-CXP use a fan tray for cooling. GigaVUE- TA100and TA100-CXP Fan Tray Specifications summarizes the characteristics of the fan tray.
  • Page 69 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) GigaVUE-TA100and TA100-CXP Fan Tray Specifications 12V DC Rated Voltage Maximum 18W Input Power 19000 RPM Maximum Speed Dual axial flow fans Type Fan Tray Specification for GigaVUE-TA200 The GigaVUE-TA200 uses a fan tray for cooling. The below table summarizes the characteristics of the fan tray.
  • Page 70 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Environmental Specifications Table 11: Environmental Specifications for GigaVUE TA Series-TA10 and GigaVUE TA Series-TA40 summarizes the environmental specifications for the GigaVUE TA Series Traffic Aggregation nodes, GigaVUE TA Series-TA10 and GigaVUE TA Series-TA40. Table 12: Environmental Specifications for GigaVUE TA Series-TA100, TA100-CXP, TA200,TA25...
  • Page 71 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Safety GigaVUE TA Series Traffic Aggregation nodes are compliant with the following safety regulations: UL 60950-1, 2nd Edition ■ UL 62368-1, 2nd Edition (GigaVUE TA Series-TA400) ■ CAN/CSA C22.2 No. 60950-1-07, 2nd Edition ■ CAN/CSA C22.2 No. 62368-1-14, 2nd Edition (GigaVUE TA Series-TA400) ■...
  • Page 72 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Environmental GigaVUE TA Series Traffic Aggregation nodes are compliant with the following environmental regulations: EU RoHS 6, EU directive 2011/65/EU ■ NEBS Level 3 (GigaVUE TA Series-TA10, GigaVUE TA Series-TA40, and GigaVUE TA ■ Series-TA100). Refer to C NEBS Level 3 Compliance on page 101.
  • Page 73 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) The RoHS label for Taiwan BSMI for GigaVUE-TA400 is as follows: VCCI The Class A Information Technology Equipment (ITE) label for Japan is as follows: Contents...
  • Page 74 Warranty Gigamon offers a range of premium support and extended services. For details regarding warranty, visit: https://www.gigamon.com/support/warranty. Regulatory Labels This section provides regulatory labels for GigaVUE TA Series TA Series nodes.
  • Page 75 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) GigaVUE-TA10 GigaVUE-TA40 Contents...
  • Page 76 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) GigaVUE-TA100 GigaVUE-TA100-CXP Contents...
  • Page 77 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) GigaVUE-TA200 GigaVUE-TA25 Contents...
  • Page 78 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) GigaVUE-TA400 NEBS Level 3 Compliance This appendix provides installation instructions for GigaVUE TA Series-TA10, GigaVUE TA Series-TA40, GigaVUE TA Series-TA100, and GigaVUE TA Series-TA200 Network Equipment-Building System (NEBS) Level 3 compliance. Installation Instructions GigaVUE TA Series-TA10,...
  • Page 79 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) 2 or Type 4 ports as described in GR-1089-CORE, Issue 6) and require isolation from the exposed OSP cabling. The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring.
  • Page 80 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) GigaVUE-TA200 equipment or subassembly are suitable for connection to intrabuilding or unexposed wiring or cabling only. The intra-building port(s) of the equipment or subassembly MUST NOT be metallically connected to interfaces that connect to the OSP or its wiring.
  • Page 81 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Class B Voltage Accessibility The GigaVUE TA Series-TA10, GigaVUE TA Series-TA40, GigaVUE TA Series-TA100, or GigaVUE TA Series-TA200 and GigaVUE-TA25 shall be located in a restricted access location where only crafts personnel are allowed access.
  • Page 82 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Unplated connection surfaces that are to be intentionally joined to form a bonding or grounding path shall be brought to a bright finish and then coated with an antioxidant before they are joined (electrical connections).
  • Page 83 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Maintenance ATTENTION : Retirez toutes les sources d’alimentation avant de procéder à l’entretien. (POUR RETIRER COMPLÈTEMENT L’ALIMENTATION DE L’APPAREIL, ÉTEIGNEZ D’ABORD L’INTERRUPTEUR D’ALIMENTATION, PUIS RETIREZ LES DEUX CÂBLES ÉLECTRIQUES). Contents...
  • Page 84 Documentation Downloads download all PDFs. Table 1: Documentation Set for Gigamon Products GigaVUE TA Series 5.16 Hardware and Software Guides ? If you keep all PDFs for a release in common folder, you can easily search across the doc set ID YOU KNOW by opening one of the files in Acrobat and choosing Edit >...
  • Page 85 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) GigaVUE TA Series 5.16 Hardware and Software Guides Software Installation and Upgrade Guides GigaVUE-FM Installation, Migration, and Upgrade Guide GigaVUE-OS Upgrade Guide Administration GigaVUE Administration Guide covers both GigaVUE-OS and GigaVUE-FM Fabric Management GigaVUE Fabric Management Guide how to install, deploy, and operate GigaVUE-FM;...
  • Page 86 GigaVUE TA Series 5.16 Hardware and Software Guides H Series and TA Series devices GigaVUE-OS Cabling Quick Reference Guide guidelines for the different types of cables used to connect Gigamon devices GigaVUE-OS Compatibility and Interoperability Matrix compatibility information and interoperability requirements for Gigamon devices GigaVUE-FM REST API Reference in GigaVUE-FM User's Guide...
  • Page 87 Product: "GigaVUE-FM" and Release: "5.6," enter "pdf" in the search box, and then click GO to view all PDF documentation for GigaVUE-FM 5.6.xx. : My Gigamon is available to registered customers only. Newer documentation PDFs, with the exception of release notes, are all available through the publicly available online documentation.
  • Page 88 You can also refer to https://www.gigamon.com/support-and-services/contact-support Technical Support hours and contact information. Email Technical Support at support@gigamon.com. Contact Sales Use the following information to Gigamon channel partner or Gigamon sales representatives. Telephone: +1.408.831.4025 Additional Sources of Information Contact Technical Support...
  • Page 89 ■ Download the latest product updates and documentation (Customers only) ■ The Gigamon Community is a great way to get answers fast, learn from experts and collaborate directly with other members around your areas of interest. Register today at community.gigamon.com Questions? Contact our Community team at community@gigamon.com.
  • Page 90 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) Glossary decrypt list need to decrypt (formerly blacklist) decryptlist need to decrypt - CLI Command (formerly blacklist) drop list selective forwarding - drop (formerly blacklist) forward list selective forwarding - forward (formerly whitelist) leader leader in clustering node relationship (formerly master)
  • Page 91 GigaVUE-TA100-CXP Hardware Installation Guide (EOS) nodecryptlist no need to decrypt- CLI Command (formerly whitelist) primary source root timing; transmits sync info to clocks in its network segment (formerly grandmaster) receiver follower in a bidirectional clock relationship (formerly slave) source leader in a bidirectional clock relationship (formerly master)