Hitachi R410A Series Installation And Operation Manual

Window type air conditioner
Hide thumbs Also See for R410A Series:

Advertisement

&
INSTALLATION
& OPERATION
MANUAL
Window Type Air Conditioner
Inverter Cooling only Series
R410A
Model
RAW-VJ07SCASK
RAW-VJ10SCASK
RAW-VJ13SCASK
RAW-VJ18SCASK
RAW-VJ24SCASK
HO202 2 4 7 6 HA

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi R410A Series

  • Page 1 & INSTALLATION & OPERATION MANUAL Window Type Air Conditioner Inverter Cooling only Series R410A Model RAW-VJ07SCASK RAW-VJ10SCASK RAW-VJ13SCASK RAW-VJ18SCASK RAW-VJ24SCASK HO202 2 4 7 6 HA...
  • Page 3: Table Of Contents

    CONTENTS Thank you for choosing Hitachi air conditioner. Please read this operating manual carefully before operating the unit and keep it for consultation Structure mechanism and Installation Precautions 1 - 2 Operating condition Power requirement 3 - 4 Installation 5 - 7...
  • Page 4 Explanation of Symbol Indicates a hazardous situation that, if not avoided, DANGER will result in death or serious injury. Indicates a hazardous situation that, if not avoided, could result in death or serious injury. WARNING Indicates a hazardous situation that, if not avoided, may result in minor or moderate injury.
  • Page 5: Precautions

    Precautions Warning Children shall not play with the appliance. The air conditioner should be installed in accordance with national wiring regulations. Air Conditioner should be properly grounded. Incorrect grounding may cause electric shock. • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 6: Operating Condition

    Structure mechanism and Installation • Operating condition Please operate air conditioner in the correct conditions as follows. COOL mode operation DRY mode operation Outdoor temperature should be in Outdoor temperature should be in range of 18˚C to 43˚C. range of 18˚C to 43 ˚C.
  • Page 7 Structure mechanism and Installation Operation Temperature : 18-43 o C / 64-109 o F Outdoor temp: Cooling operation 17-32 o C / 62-90 o F Indoor temp: Note: Performance may be reduced outside of these operating temperatures. Power cord RAW-VJ24SCASK 1.
  • Page 8: Installation

    Structure mechanism and Installation • Installation Installation precaution: Please contact the professional technician to install the unit and don’t install it by yourself. Otherwise, we are not responsible for the damage of unit. Location: • The condensation water must be drained away easily. •...
  • Page 9 Structure mechanism and Installation • Installation Installation procedure : 1. Remove the sticker from the front panel. 2. Put the unit into the installation hole. When installing the unit, it should slant down to the back to make sure the condensation water can be drained away easily.
  • Page 10 Structure mechanism and Installation • Installation Drain water for another style : To get the maximum cooling efficiency, the air conditioner is designed to splash the condensate on the condenser coil. Please install the drainage tray when installing the air conditioner if necessary. To the cooling only unit, if the splashing sound annoys you, you can use an outside drain as shown in the following procedure.
  • Page 11: Notes For Installation

    Structure mechanism and Installation • Notes for installation Removal Before removing air conditioner to the other place, you should contact the seller firstly. Then it must be done under the direction of the professional technician. Noise • Install in a location where is firm enough to avoid the enlargement of noise and vibration.
  • Page 12: Installation Steps

    Structure mechanism and Installation • Installation Steps Step 1. Remove the front panel and the air filter Hold the slot under the front panel, then uplift outwards, and remove the front panel (See Fig. 1). Pinch the handle under the air filter and make the air filter arched, remove it from the slot from unders ide to upside (See F ig.
  • Page 13: Operation Procedure

    Operation procedure • Part identification Panel outlook picture is just for reference, please take the real unit as standard outlook. • Airflow direction Adjustment Horizontal airflow direction vane (Airflow direction adjustment up and down) The horizontal airflow direction vane is controlled by positioning the vane to discharge the air upwards, downwards or straight out.
  • Page 14: Air Filter And Cabinet Cleaning

    Operation procedure • Air Filter The air filter behind the inlet grille should be checked and cleaned at least once every 2 weeks (or as necessary) to maintain optimal performance of the air conditioner. How to remove the air filter Tum off...
  • Page 15: Remote Control Operation Procedure

    Operation procedure • Remote control operation procedure Note: This is a general use remote control, it could be used for the air conditioners with multifunction. For some functions which the model doesn’t have, the unit will keep the original running status if pressing the corresponding button on the remote control. (not applicable) On / Off button Press this button to turn on the unit.
  • Page 16 Operation procedure • Remote control operation procedure ● Dry: Under this mode, the unit runs in low fan speed for dehumidifying and the corresponding indicator is on; under dry mode, the fan speed cannot be adjusted. ● Fan Only: Under this mode, air conditioner will not operate in COOL mode but only blow wind.
  • Page 17 Operation procedure • Remote control operation procedure Timer button Under ON status, press this button to set timer OFF; Under OFF status, press this button to set timer ON. Press this button once and the characters of HOUR ON (OFF) will flash to be displayed.
  • Page 18 Operation procedure Replacement of batteries in remote control signal sender battery Press the back side of remote control marked with “ “ , as shown in the Fig. , reinstall and then push out the cover of battery box along the arrow direction. remove Replace two (AAA 1.5V) dry batteries, and make sure the position of "+"...
  • Page 19: Remote Control Panel

    Operation procedure • Remote control panel Note: If wireless remote control is lost, you can use the remote control panel and operate manually. 1 ON/OFF BUTTON Operation starts when pressing this button. Pressing this button again to stop the operation. 2 SWING BUTTON Activate the automatic air swing function.
  • Page 20: Operation Tips

    Operation procedure • Operation Tips Operation for comfort and economy Keep the room temperature Keep the blind or curtains Do not overcool the room consistent. Adjust the vertical closed. Do not let sunshine temperature. This is not and horizontal airflow direction entering the room directly good for health and to ensure consistent...
  • Page 21: Care And Maintenance

    Care and maintenance • Caution Operations for safety and health The plug must be accessible after the appliance is positioned. Do not use this appliance in the laundry. If the power cord is damaged, it must be replaced by the manufacture or its service agent in avoid of hazard.
  • Page 22: Cleaning And Maintenance

    Care and maintenance • Cleaning and maintenance • Cleaning and maintenance Always turn off the air conditioner and main power supply before cleaning Air filter to ensure safety. The air filter behind the intake grille should be washed at least once every two weeks or as often as it needs cleaning.
  • Page 23: Troubleshooting Guide

    Care and maintenance • Troubleshooting guide Please check the following items before asking for repair, it saves your time and money. Fault phenomenon Trouble - shooting  Is there a power failure? Air conditioner  Is the plug out? does not operate ...
  • Page 24: After Sales Service

    Care and maintenance Immediately stop all operations and plug out or isolate power supply, please contact your dealer in the following situations. * Operation starts or stops abnormally; * Power fuse or switch often breaks; * Carelessly splash water or something into air conditioner; * Electrical lines are much hot or lines cover breaks;...
  • Page 25 They can take this product for environmental safe recycling. Specifications in this document are subject to change without notice, in order that Hitachi-Johnson Controls Air Conditioning, Inc. may bring the latest innovations to their customers Hitachi-Johnson Controls Air Conditioning, Inc.

Table of Contents