Installation Steps - Hitachi R410A Series Installation And Operation Manual

Window type air conditioner
Hide thumbs Also See for R410A Series:
Table of Contents

Advertisement

Structure mechanism and Installation

Installation Steps

Step 1.
Remove the front panel and the air filter
1.
Hold the slot under the front panel, then uplift outwards, and remove the front panel
(See Fig. 1).
2.
Pinch the handle under the air filter and make the air filter arched, remove it from the
slot from unders ide to upside (See F ig. 2).
3.
Cut and remove the cable tie (See Fig. 3) fixing between the panel and the temperature
sensor behind the air filter. (Only applicable for RAW-VJ18SCASK and
RAW-VJ24SCASK).
Step 2.
Remove the frame.
1.
Remove one screw on the chassis fixing bracket, then remove the chassis fixing bracket.
Remove the two screws located on the back of the cabinet as shown in Fig. 4 if necessary.
2.
Grasp the left corner of the frame's underside, then loosen the frame. (See Fig. 5).
After that use a flathead screwdriver to press the clip connecting between the control
panel and the frame, finally remove the frame.
3.
Grasp the handle on the chassis and carefully silde the air conditione r out of th e cabin et
(See Fig. 6).
given into the package if necessary.
Step 3.
Install the frame.
1.
Push the unit chassis into the cabine t (S ee Fig. 7).
2.
Install the frame (See Fig. 8) and fix the scr ews on the fram e (See Fig. 4)
Step 4.
Install the air filter and front panel.
1.
Install the Silver Ion air filter into the frame's slot from upside to underside. (See Fig. 9).
2.
Hang the front panel on th e fram e's buckle , the n pr ess the front pane l into the fram e's slot
untiI you he ar a click (S ee Fig. 10)
Rubber Plug is fixed in the drain hole. Please use the spare rubber plug
9 -
-

Advertisement

Table of Contents
loading

Table of Contents