Removing The Device - Nice Flood-Control Instructions And Warnings For Installation And Use

Wireless water leak detector
Table of Contents

Advertisement

4
ADDING THE DEVICE
Adding in security mode must be performed up to 2 meters from the controller.
In case of problems with adding the device, please reset the device and repeat the adding procedure.
Adding (Inclusion) - Z-Wave device learning mode, allowing to add the device to existing Z-Wave network.
To add the device to the Z-Wave network manually:
1. Open the cover.
2. Place the Sensor within the direct range of your Z-Wave controller.
3. Set the main controller in (security/non-security) add mode (see the controller's manual).
4. Quickly, three times press the TMP button.
TMP
button
5. Wait for the adding process to end.
6. Successful adding will be confirmed by the Z-Wave controller's message.
5

REMOVING THE DEVICE

Removing (Exclusion) - Z-Wave device learning mode, allowing to remove the device from existing Z-Wave network.
To remove the device from the Z-Wave network:
1. Open the cover.
2. Place the Sensor within the direct range of your Z-Wave controller.
3. Set the main controller into remove mode (see the controller's manual).
4. Quickly, three times press the TMP button.
TMP
button
5. Wait for the removing process to end.
6. Successful removing will be confirmed by the Z-Wave controller's message.
Note. Removing the device from the Z-Wave network restores all the default parameters of the device.
6
DIAGRAMS AND CONNECTIONS
Connecting Flood-Control in a manner inconsistent with manual may cause risk to health, life or material damage.
Connect while observing wiring diagram shown in this manual only. Incorrect wiring may be dangerous or result in the device breakdown.
Remember to keep the device away from water or protect holes for wires from water to avoid destroying the device.
To prevent accidental pulling out make certain that cables are firmly attached to the wire connectors and screws are properly tightened.
Make sure to secure the power cord after connecting it to the terminal.
The TMP button has two functions:
» Adding / Removing the device to / from the Z-Wave network,
» Tamper contact for 4th Association Group. When a sensor is added to the Z-Wave network, cover open alarm may be activated (ac-
cording to parameter 74 settings).