Parameter:
7. Requested dimming level / roller blind opening level when sending turn on / open command to 2nd association
group devices
Description:
Determines the requested "on" level to be sent to devices from 2nd association group upon flood event.
Available settings:
1-99 - requested level
255 - turn a device on
Default setting:
255
Parameter:
9. Deactivate turning off devices in 2nd association group & alarm cancellation in 3rd group
Description:
This setting decides whether device turn off commands and alarm cancellation notifications will be sent to devices
in 2nd and 3rd association groups (respectively)
Setting the parameter's value to 0 disables sending these two commands to associated devices. This means that
these devices WILL NOT be informed when the flooding has ceased. It is still possible to cancel alarms in 3rd as-
sociation group by choosing second (green) menu position (see section 8.2 - Visual indications).
Available settings:
0 - alarm (flooding) cancellation inactive
1 - alarm (flooding) cancellation active
Default setting:
1
Parameter:
10. Temperature measurement interval
Description:
Time interval (in seconds) between consecutive measurements of battery level and temperature (done by built-in
temperature sensor).
If the temperature differs from previously reported by a value determined in parameter 12, it will be reported to
the Z-Wave controller.
In battery mode more significant battery level changes will be reported. Short time intervals mean more frequent
communication, which results in shortened battery life.
After consecutive FAILED and SUCCESSFUL communication attempts, the Sensor will go to standby mode.
Available settings:
1-65535 (in seconds)
Default setting:
300 (5min)
Parameter:
12. Temperature measurement hysteresis
Description:
Determines a minimum temperature change value (insensitivity level), resulting in a temperature report being sent
to the main controller, according to the parameter 10 settings.
Available settings:
1-1000 (each 0.01°C)
Default setting:
50 (0.5°C)
Parameter:
50. Low temperature alarm threshold
Description:
The parameter stores a temperature value, below which visual indicator blinks with a colour determined by a
parameter 61 settings. By default the visual indicator blinks blue.
Available settings:
- 10000 to +10000 (each 0.01°C)
Default setting:
1500 (15°C)
Parameter:
51. High temperature alarm threshold
Description:
The parameter stores a temperature value, above which visual indicator blinks with a colour determined by the
parameter 62 settings. By default the visual indicator blinks red.
Available settings:
- 10000 to +10000 (each 0.01°C)
Default setting:
3500 (35°C)
Parameter:
61. Low temperature alarm indicator colour
Description:
Parameter stores RGB colour value (see Table A3 for details).
Available settings:
0-16777215
Default setting:
255
Parameter:
62. High temperature alarm indicator colour
Description:
Parameter stores RGB colour value (see Table A3 for details).
Available settings:
0-16777215
Default setting:
16711680
Parameter size:
2 [bytes]
Parameter size:
1 [byte]
Parameter size:
4 [bytes]
Parameter size:
2 [bytes]
Parameter size:
2 [bytes]
Parameter size:
2 [bytes]
Parameter size:
4 [bytes]
Parameter size:
4 [bytes]