Summary of Contents for Riello RBS 200 2S

  • Page 1 RBS 200-300-430-550 2S RBS 800-1000 2S RBS 2S EN INSTALLATION, OPERATION AND MAINTENANCE MANUAL...
  • Page 2: Table Of Contents

    GENERAL INFORMATION GENERAL INFORMATION RANGE The following symbols are used in this manual: MODEL CODE CAUTION! = Identifies actions that require caution and ad- RBS 200 2S 20116675 equate preparation. RBS 300 2S 20116335 RBS 430 2S 20117339 STOP! = Identifies actions that you MUST NOT do.
  • Page 3: Precautions

    This lists the technical specifications and performance of the Never attempt to install the system without using suitable product. personal protection equipment and without following all applicable occupational safety standards. RIELLO S.p.A. Via Ing.Pilade Riello 7 37045 Legnago (VR) - ITALY BOLLITORE SOLARE T067765IES SOLARBOILER INTERACUMULADOR SOLAR...
  • Page 4: Technical Specifications

    GENERAL INFORMATION GENERAL INFORMATION 6 TECHNICAL SPECIFICATIONS RBS 2S DESCRIPTION 1000 Type of storage cylinder Vertical, glazed Heat exchanger layout Vertical, with elliptical section Storage cylinder capacity Useful non-solar volume (Vbu)* Solar usable volume (Vsol)** Diameter of storage cylinder with insulation 1000 1000 Diameter of storage cylinder without insulation...
  • Page 5 GENERAL INFORMATION GENERAL INFORMATION RBS 2S EMPTYING IN 10’ 1000 PERFORMANCE RELATING TO INTEGRATION COIL Quantity of domestic water obtained in 10’ with heater pre-heated to 60°C (*) and primary exchanger at the indicated deliv- ery temperature, considering an increase of the domestic water temperature of 30°C between inlet and outlet (according to EN 12897).
  • Page 6: Installation

    INSTALLATION INSTALLATION 7 UNPACKING THE PRODUCT − Close the interlocking flaps (L) completely, which were previously left with an open tooth RBS 2S solar heaters are supplied in a single package on a − Fit the cover of the inspection flange using the two wooden pallet.
  • Page 7: Water Connections

    INSTALLATION INSTALLATION 11 WATER CONNECTIONS RBS 200 - 550 2S RBS 800 - 1000 2S RBS 200 RBS 300 - 430 - 550 RBS 1000 RBS 800 RBS 2S DESCRIPTION 1000 Domestic hot water outlet 1” M 1"1/4 M Ø Outlet from boiler 1”...
  • Page 8: Technical Assistance Service

    TECHNICAL ASSISTANCE SERVICE TECHNICAL ASSISTANCE SERVICE 12 PUTTING INTO SERVICE 13 TEMPORARY SHUTDOWN It is essential to perform the following checks before starting up If you are going away for a short period of time like a weekend or testing the functioning of the storage cylinder. In particular, or a short holiday, etc., and outdoor temperatures are going to check that: remain above ZERO, proceed as follows.
  • Page 9: Maintenance

    TECHNICAL ASSISTANCE SERVICE TECHNICAL ASSISTANCE SERVICE 15 MAINTENANCE Scheduled maintenance is essential for the safety, efficiency and long working life of your storage cylinder. Proper maintenance also reduces energy consumption and ensures reliability over time. Have your storage cylinder serviced either by the manu- facturer’s Technical Assistance Service or by a qualified heating engineer at least once a year.
  • Page 10: Recycling And Disposal

    TECHNICAL ASSISTANCE SERVICE TECHNICAL ASSISTANCE SERVICE 16.1 Troubleshooting SUPPLEMENTARY HEATING CIRCUIT FAULT CAUSE SOLUTION − Fit a pressure limiter Flow rate too high − Fit a flow reducer There are blockages or deposits in the − Check and clean as necessary domestic hot water circuit The storage cylinder functions incorrectly or irregularly...
  • Page 11: End User

    END USER END USER END USER INSTRUCTIONS Refer to the GENERAL SAFETY INFORMATION and PRECAUTIONS section for safety-related information. 18 START-UP 19 TEMPORARY SHUTDOWN The heater commissioning must be performed by Technical As- To reduce to the environmental impact and save energy, in case sistance Service personnel.
  • Page 12 RIELLO S.p.A. Via Ing. Pilade Riello, 7 37045 - Legnago (VR) www.riello.com The manufacturer strives to continuously improve all products. Appearance, dimensions, technical specifications, standard equipment and accessories are therefore liable to modification without notice.