Philio Technology Corporation PSP06 Manual

Philio Technology Corporation PSP06 Manual

Pir sensor

Advertisement

Quick Links

PIR Sensor
PSP06
The PIR sensor PSP06 has PIR, based on Z-Wave
TM
It is the Z-Wave
plus product, it support the security, OTA... Those
newest features of the Z-Wave
communication protocol designed for home automation, specifically to
remotely control applications in residential and light commercial
environments. The technology uses a low-power RF radio embedded or
retrofitted into home electronics devices and systems, such as lighting,
home access control, entertainment systems and household appliances.
This product can be included and operated in any Z-Wave
TM
with other Z-Wave
certified devices from other manufacturers and/or
other applications. All non-battery operated nodes within the network
will act as repeaters regardless of vendor to increase reliability of the
network.
TM
technology.
TM
TM
technology. Z-Wave
is a wireless
TM
The device adopt the Z-Wave
network system is all made by Z-Wave
network system will have the advantages as below.
Concurrent multi-channel support reduces external interference.
Better RF range, improve about 10 meters in indoor.
Support 100 Kbps transmit speed, speed up communication.
Specification
Power
Battery life
RF distance
RF Frequency
RF Maximum Power
Location
Operation temperature -20
Humidity
Dimension
FCC ID
Specifications are subject to change and improvement without notice.
Indication of battery life : Alarm Report PIR:50 times/Day, Auto
Report:4 times/ Day, Auto Wake up:1 times/ Day.
Troubleshooting
network
Symptom
The device can not
join to Z-Wave™
network
1
TM
700 series chip, when your Z-Wave
TM
700 series devices. The
3VDC (CR123A lithium battery)
10 years
Min. 40M indoor,
100M outdoor line of sight,
868.40 MHz, 869.85 MHz(EU)
908.40 MHz, 916.00 MHz(US)
920.9MHz, 921.7MHz, 923.1MHz
(TW/KR/Thai/SG)
+10dBm (Peak), -10dBm (Average)
indoor use only
o
o
C ~ 50
C
85%RH max
82 x 25.3 x 23.2 mm
RHHPSP06
Cause of Failure
Recommendation
The device may in a Z-
Exclude the device
Wave™ network.
then include again.
TM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSP06 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Philio Technology Corporation PSP06

  • Page 1 Operation temperature -20 C ~ 50 Humidity 85%RH max The PIR sensor PSP06 has PIR, based on Z-Wave technology. Dimension 82 x 25.3 x 23.2 mm It is the Z-Wave plus product, it support the security, OTA... Those newest features of the Z-Wave technology.
  • Page 2 Overview For Instruction to http:// www.philio-tech.com CAUTION – replacement of a battery with an incorrect type that can defeat a safeguard (for example, in the case of some lithium battery types); – disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery, that can result in an explosion;...
  • Page 3 *notice1:The QR code can be found on the device 2. Pressing the tamper key three times within 1.5 seconds to enter the inclusion mode. PSP06 or on the box. 3. After add successful, the LED will light ON 1 This machine provides two groups of nodes.
  • Page 4 Notice 1: Always RESET a Z-Wave device before trying to add it to a * Tamper Report: Z-Wave network Both the 2 tamper keys are pressed over 5 seconds. The device will into the alarm state. In that state, if any one of the tamper keys be released, the device will unsolicited to send the report to the nodes in the group 1.
  • Page 5: Battery Installation

    Battery Installation *PIR Warm Up When the device power on, the PIR need to warm up before the operation. The warm up time about 1 minute, the LED will flash in User need change the battery while the device is showing battery low every 2 seconds.
  • Page 6: Installation

    fig 1 fig 2 Installation fig 3 1. In the first time, add the device into the Z-Wave network. First, make sure the primary controller is in the inclusion mode. And then power on the device, just take out the insulation Mylar in the back side of the device.
  • Page 7 Choosing A Mounting Location Select the mounting location so that the expected motion of an intruder would cross. the detector’s coverage pattern. The device comes to Wall-mounted. Before selecting a position for a Motion Detector the following points should be noted: 1.
  • Page 8: Z-Wave Supported Command Class

    Z-Wave Supported Command Class Vali Name Def. Description Command Class Version Required Security Class Bit3: Reserve. Z-Wave Plus™ Info None Bit4: Reserve. Security None Bit5: Reserve. Security 2 None Bit6: Reserve. Supervision None Bit7: Reserve. None Setting the BASIC command value. Transport Service Basic ON 0xFF...
  • Page 9: Fcc Interference Statement

    They can take this product for operate this equipment. environmental safe recycling. This transmitter must not be co-located or operating in conjunction Philio Technology Corporation with any other antenna or transmitter. 8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257, Taiwan(R.O.C) www.philio-tech.com...

Table of Contents