3
2
3 Mounting the Indoor Unit
(1) Installing the nuts and washers to the suspension bolts
.
Fig
*Place the washer so that the surface with insulation faces downwards.
(2) Lift the Indoor Unit by hoist, and do not apply any force on the drain pan.
(3) Secure the indoor unit using the nuts and washer.
NOTE:
If a false ceiling is already constructed, complete all piping and wiring work inside the ceiling
before securing the indoor unit.
Unit: in. (mm)
9K~12K
Fig.3.6 Indoor Unit and Air Panel
.
3
7 Mounting Nuts and washer
Fig.3.8 Mounting the Indoor Unit
Installation and Maintenance
Liquid Pipe Connection
Gas Pipe Connection
18K~36K
.
Unit: in. (mm)
11
Unit: in. (mm)
Drain Pipe Connection
Wiring Knockout
ø1-1/4(32.5) Hole
(for Spare)
Wiring Knockout
1-3/16 x 1-3/16(30x30)
(for Cable)
a
Model
in. (mm)
9K~12K 4-5/16(110)
18K~36K
4-1/32(102)