(Compared with the existing remote, M8 connector/8 digital
inputs specification)
Modular Type EX600-W
Up to 9 stations can be
¡
connected to the digital/analog
unit.
Connector type: M12/M8, D-sub,
¡
Spring type terminal block
For countries/regions in which wireless is supported
This product cannot be used in countries/regions where wireless is not supported. Refer to page 44 for details on countries/regions in which the product can be used.
EXW1/EX600-W
reduction
∗
1
reduction
∗
1
Series
Communication distance/speed,
Response time
Communication distance Communication speed
Compact Type
100 m
EXW1
Modular Type
10 m
EX600-W
∗ For the EXW1 construction, it depends on the operating environment.
Fieldbus system cc-link ie tsn compatible si unit (28 pages)
Summary of Contents for SMC Networks EXW1 Series
Page 1
Wireless System RoHS Noise resistance Communication distance/speed, Response time Uses the 2.4 GHz ISM frequency band Frequency hopping: Every 2 ms (Fastest) Communication distance Communication speed Response time Communication cables 2 ms 1 Mbps Compact Type 100 m EXW1 250 kbps 5 ms not required Modular Type...
Page 2
Compact Type EXW1 /Modular Type EX600-W Wireless System Series Series Provides communication stability in FA environments Compact Modular EXW1 EX600-W Even if multiple wireless bases are in use in the same communication area, each wireless base is able to effectively ¡...
Page 3
Compact Type EXW1 /Modular Type EX600-W Wireless System Series Series Frequency hopping/Event communication system Compact Modular EXW1 EX600-W Frequency hopping Frequency hopping cycle A stable wireless environment is established using an ∗ original protocol which is not affected by interference. Actual communication time Interference from other wireless equipment is reduced.
Page 4
Compact Type EXW1 /Modular Type EX600-W Wireless System Series Series Product diagnosis Compact Modular EXW1 EX600-W Diagnostic signals LEDs on the base/remote Web function setting software (IO Configurator) , and can be used for product diagnostics. Web screen example Diagnostic signal Web function ∗...
Page 5
Compact Type EXW1 /Modular Type EX600-W Wireless System Series Series Product diagnosis Compact Modular EXW1 EX600-W Setting software (IO Configurator) Setting software Download the setting software from the “configuration file.” The NFC reader/writer can be used with the setting software to perform various checks and setting without contact.
Page 6
Compact Type EXW1 /Modular Type EX600-W Wireless System Series Series ∗ The compact EXW1 and the modular EX600-W can be mixed. ∗1 When they are mixed, the communication speed/response time is limited to the EX600-W’s specifications. (Refer to the system configuration examples.) System Examples Fieldbus Wireless base...
Page 7
External antenna Applicable Configuration example when using the EXW1 series base w Compact Type (When the remote configuration is for the EX600-W and the EXW1 series) EXW1 10 m between the EXW1 (base) and the EX600-W (remote) Approx.
Page 8
Compact Type EXW1 /Modular Type EX600-W Wireless System Series Series Wiring material cost and installation time can be Compact Modular EXW1 EX600-W ∗ reduced. ∗1 For the EX600-W modular type Wireless System Existing (Wired) System Power supply Base Power supply line Communication line q Communication line q Power...
Page 9
Compact Type EXW1 /Modular Type EX600-W Wireless System Series Series Application Examples ¡A communication cable is not necessary for moving parts. ¡Minimized disconnection risk For tool changing ¡Shorter time for establishing communication (startup time) For rotary tables Wired system Communication Power supply M inimized disconnection risk ¡...
C O N T E N T S Wireless System EXW1 EX600-W Compact Type Modular Type Series Series Compact wireless base Compact wireless Base module Remote module remote input/output How to Order Wireless Unit p. 24 Digital Input Unit p. 24 Digital Output Unit p.
Wireless System Compact Type EXW1 Series How to Order EXW1 B MJ A B E Compact Wireless Base Frequency channel select function Compact wireless Number of selectable Symbol Applicable countries frequency channels Base Countries with Radio Law certification 5 to 79 ch outside the U.S./Canada/Korea Communication protocol 15 to 79 ch...
EXW1 Series Specifications: Compact Wireless Base Wireless Communication Specifications Item Specifications Protocol SMC original protocol (SMC encryption) Between compact V.2.0 or V.1.0 (Selectable) EXW1 remote Between modular V.1.0 EX600-W remote Radio wave type (spread) Frequency Hopping Spread Spectrum (FHSS) Frequency 2.4 GHz (2403 to 2481 MHz) Number of frequency channels 5 to 79 ch (Countries other than the U.S., Canada, and South Korea), 15 to 79 ch (U.S., Canada, and South Korea)
EXW1 Series Wireless System Compact Type Specifications: Compact Wireless Remote Communication Specifications (Common) Item Specifications Protocol SMC original protocol (SMC encryption) Between compact V.2.0 or V.1.0 (Selectable) EXW1 bases Between modular V.1.0 EX600-W bases Radio wave type (spread) Frequency Hopping Spread Spectrum (FHSS) Frequency 2.4 GHz (2403 to 2481 MHz) Number of frequency channels...
EXW1 Series Dimensions/Parts Description Compact Wireless Base Model label EXW1-BMJAm Internal antenna External antenna External antenna set EXW1-BMJAB 90.8 20.3 ±0.1 15.3 Radio Act-compliance label 2 x M4 mounting hole FE terminal ∗ The seal cap is attached when shipped. Power supply connector Communication connector BUS OUT 2 x ø4.5...
Page 15
EXW1 Series Wireless System Compact Type Dimensions/Parts Description Compact Wireless Remote Input/Output EXW1-RDMmmmm Model label Internal antenna External antenna External antenna set EXW1-RDMPE3BE 26.7 90.8 LED indicator 20.3 ±0.1 Indicator label 15.3 Radio Act-compliance label 2 x M4 mounting hole FE terminal INPUT (Connector for input device connection) OUTPUT (Connector for output device connection)
Page 16
EXW1 Series Dimensions/Parts Description Compact Wireless Remote Input Model label EXW1-RDXmmmm Internal antenna External antenna External antenna set EXW1-RDXNE4BE 26.7 90.8 LED indicator 20.3 ±0.1 Indicator label 15.3 Radio Act-compliance label 2 x M4 mounting hole FE terminal INPUT (Connector for input device connection) 2 x ø4.5 Fn (Push button for pairing) RF (SMA coaxial connector)
Page 17
EXW1 Series Wireless System Compact Type Dimensions/Parts Description Compact Wireless Remote Output EXW1-RDYmmmm Model label Internal antenna External antenna External antenna set EXW1-RDYNE4BE 26.7 LED indicator 90.8 20.3 ±0.1 Indicator label 15.3 Radio Act-compliance label 2 x M4 mounting hole FE terminal OUTPUT (Connector for output device connection) 2 x ø4.5...
EXW1 Series LED Display Compact wireless base q w e r t y u LED status Function Description Color of name Flashing Green Communication is normal. Data link status LRUN Communication is not established or the indication — US1 (for control) power supply is OFF. A communication error has occurred.
Page 19
EXW1 Series Wireless System Compact Type LED Display Compact wireless remote input/output q w e r LED status Function Description Color of name Flashing The US1 (for control/input) power supply is Green Power supply The US2 (for output) power supply voltage voltage (US1/ Flashing level is abnormal (when the setting is...
EXW1 Series Accessories (Optional Parts) Compact Wireless Base Compact Wireless Remote P ower Supply P ower Supply Cable Connector, Connector for Input/Output Device Connection (e-CON) E xternal Antenna Set External Antenna Set Seal Cap (M12) Communication Cable F ield-wireable Communication Connector q Power Supply Cable (M12 connector) * The shape of the M12 connector is B-coded (Reverse key).
EXW1 Series Accessories w Communication Cable 44.5 5000 For CC-Link 22.5 ∗1 PCA-1567720 (Socket) Marker tag Marker tag Shield Socket connector pin arrangement A-coded (Normal key) SPEEDCON ∗1 Number of holes: 5, 47.3 5000 Total number of pins: 4 22.5 PCA-1567717 (Plug) Marker tag...
EXW1 Series e Field-wireable Communication Connector Plug Applicable Cable ≈ 60 Item Specifications For CC-Link Cable O.D. 4.0 to 8.0 mm 0.14 to 0.75 mm /AWG26 to 18 PCA-1075526 Wire gauge (Solid cable/Flexible cable) (Stranded wire A-coded 0.08 to 0.5 mm /AWG28 to 20 Width across flats 16 cross section)
EXW1 Series Accessories y Power Supply Connector, Connector for Input/Output Device Connection (e-CON) Select the applicable e-CON connectors based on the lead wire specifications of the components to be connected. Both the power supply and I/O connectors have the same shape as the e-CON (4-pin, socket). The lead wire specifications of each of our I/O devices are shown below for reference.
EXW1 Series Made to Order Please contact SMC for detailed specifications and lead times. q Communication Cable With connector on one side (Socket) Dimensions Cable length: 10000 mm For CC-Link For CC-Link 44.5 10000 EX9- AC100 MJ - X12 22.5 Applicable protocol Marker tag Marker tag...
Wireless System Modular Type EX600-W Series RoHS How to Order EX600 Wireless Unit Wireless compatible Output type Symbol Specifications Protocol Symbol Specifications Note Base module For EtherNet/IP™ Base module Remote Base module For PROFINET module Remote module — EX600 Digital Input Unit ∗ Digital input Number of inputs and connector Symbol Number of inputs...
EX600-W Series How to Order EX600 Analog Output Unit ∗ Analog output Number of output channels and connector Symbol Number of output channels Connector 2 channels M12 connector (5 pins) 2 pcs. EX600 Analog Input/Output Unit ∗ Analog input/output Number of input/output channels and connector Symbol Number of input channels Number of output channels Connector M12 connector (5 pins)
EX600-W Series Wireless System Modular Type Ordering Example of the Base Module Base module: Without valve manifold and input/output unit Manifold with base module: With input/output unit Digital output unit Wireless unit (Base module) Digital input unit 2-position single EX600-DYPB EX600-WEN1 EX600-DXPD SY3100-5U1 (3 sets)
EX600-W Series Specifications EX600-WENm Base Module: Item Specifications Communication protocol EtherNet/IP™ (Conformance test version: Composit 12) Transmission medium (cable) Standard Ethernet cable (CAT5 or higher, 100BASE-TX) Communication speed 10 Mbps/100 Mbps Communication method Full duplex/Half duplex EDS file * Configuration file IP address setting Manual/BOOTP, DHCP EtherNet/IP™...
Page 29
EX600-W Series Wireless System Modular Type Specifications EX600-WPN Base Module: Item Specifications Communication protocol PROFINET IO Conformance class Class C (Only for IRT switch function) Transmission medium (cable) Standard Ethernet cable (CAT5 or higher, 100BASE-TX) Transmission speed 100 Mbps PROFINET GSDML file * communication Configuration file...
EX600-W Series Specifications EX600-WSVm Remote Module: Item Specifications 24 VDC ±10% Power supply voltage For control/input (US1) Current consumption 70 mA or less Electrical 24 VDC ±10% Power supply voltage For output (US2) Max. supply current Number of inputs Input size Max.
EX600-W Series Wireless System Modular Type Dimensions Base Module EX600-WENm 10.7 55.2 Area close to NFC antenna FCC ID label Radio Act-compliance label EtherNet/IP™ BUS connector, Port 1 EtherNet/IP™ BUS connector, Port 2 Marker groove ID label (EtherNet MAC address, Wireless PID (Product ID)) Model label Connector for EtherNet/IP™...
Page 32
EX600-W Series Dimensions Base Module EX600-WPNm 10.7 55.2 Area close to NFC antenna FCC ID label Radio Act-compliance label PROFINET IO BUS connector, Port 1 PROFINET IO BUS connector, Port 2 Marker groove ID label (MAC address, Wireless PID (Product ID)) PROFINET IO BUS connector, Port 1/Port 2 M12, 4-pin, D-coded, socket Pin no.
Page 33
EX600-W Series Wireless System Modular Type Dimensions End Plate (D side) EX600-ED2 (4.4) 2 x M4 direct mounting hole 85.1 20.5 Power supply connector PWR IN FE terminal Power supply connector PWR IN: M12 5-pin plug, B-coded Configuration Pin no. Description 24 V (for output) 0 V (for output)
Page 34
EX600-W Series Dimensions End Plate (D side) 42.5 EX600-ED3 EX600-ED3 2 x M4 direct mounting hole 20.5 Power supply connector PWR: 7/8 inch 5-pin plug Configuration Pin no. Description 0 V (for output) 0 V (for control/input) 24 V (for control/input) 24 V (for output) End Plate (U side) 28.2...
EX600-W Series Wireless System Modular Type LED Display Base module No. LED name Function Color of LED Operation EtherNet/IP™ communication Green LED is ON. Power supply voltage for output (US2) is normal. specifications Power supply Power supply voltage for output (US2) is abnormal. Red LED PWR (V) voltage for...
Page 36
EX600-W Series LED Display Base module No. LED name Function Color of LED Operation PROFINET communication Green LED Power supply voltage for control and input (US1) is normal, specifications is ON. and power supply voltage for output (US2) is normal. Power supply voltage for control and input (US1) is normal, Green LED Power supply...
Page 37
EX600-W Series Wireless System Modular Type LED Display Remote module No. LED name Function Color of LED Operation Green LED is ON. Power supply voltage for output (US2) is normal. Power supply Power supply voltage for output (US2) is abnormal. Red LED PWR (V) voltage for...
EX600-W Series Accessories (Optional Parts) Communication Cable Power Supply Cable (M12 connector, For EX600-ED2) Field-wireable Communication Power Supply Cable (M12 connector, For EX600-ED4/5) Seal Cap Connector (M8) I/O Cable with Connector Marker Valve Plate (When the valve manifold is in use) Seal Cap (M12) Power Supply...
EX600-W Series Accessories e End Plate (U side) The end plate is for use when the manifold valve is not connected. EX600-EU1 EX600- E U 1 - 2 28.2 2 x M4 direct mounting hole 20.5 Mounting method Symbol Description Note Without DIN rail mounting bracket —...
EX600-W Series u Power Supply Cable (7/8 inch connector, For EX600-ED3) PCA-1558810 Straight 2 m PCA-1558823 Straight 6 m PCA-1558836 Right angled 2 m PCA-1558849 Right angled 6 m Straight connector type Angled connector type 49.9 Socket pin " ø7/8 arrangement ø26 Socket pin arrangement...
EX600-W Series Accessories !0 Power Supply Cable (M12 connector, For EX600-ED4/5) * The shape of the M12 connector is A-coded (Normal key). EX500-AP 050 - S Cable length (L) Connector specification 1000 mm Straight 5000 mm Angled Straight connector type Angled connector type ø14.9 25.3...
EX600-W Series !1 Communication Cable For PROFINET For EtherNet/IP™ EX9-AC 020 EN-PSRJ (Plug/RJ-45 connector) Cable length (L) Metal parts Metal parts RJ-45 1000 mm 2000 mm 3000 mm 47.3 5000 mm Terminal Terminal Core wire 10000 mm Signal name color White/Orange Orange White/Green...
EX600-W Series Accessories !1 Communication Cable For PROFINET For EtherNet/IP™ EX9-AC 005 EN-PSPS (With connector on both sides (Plug/Plug)) 47.3 47.3 Cable length (L) 500 mm 1000 mm 2000 mm Metal parts Metal parts 3000 mm Plug connector Plug connector 5000 mm pin arrangement pin arrangement...
EX600-W Series !3 I/O Cable with Connector, I/O Connector Name Part no. Description PCA-1557769 Cable with M12 connector (4 pins/3 m) Cable with For sensor connector PCA-1557772 Cable with M8 connector (3 pins/3 m) PCA-1557730 Field-wireable connector (M8/3 pins/Plug/Piercecon connection) ®...
Page 45
Morocco, U.S., Argentina, Canada, Brazil, Mexico, India, Australia, South Korea, Singapore, Thailand, China, Japan, New Zealand, Philippines, Vietnam, Malaysia, Taiwan [Compact Type EXW1 Series] Iceland, Ireland, Italy, Estonia, Austria, Netherlands, Cyprus, Greece, Croatia, Sweden, Spain, Slovakia, Slovenia, Czech Republic, Denmark, Germany, Hungary, Finland, France, Bulgaria, Belgium, Poland, Portugal, Malta, Latvia, Lithuania, Liechtenstein, Romania, Luxembourg, U.K., Switzerland, Turkey, Norway, U.S., Canada, South Korea, Japan, Vietnam...
Page 46
EXW1/EX600-W Series Specific Product Precautions Be sure to read this before handling the products. Refer to the back cover for safety instructions. For fieldbus system precautions, refer to the “Operation Manual” on the SMC website: https://www.smcworld.com Notice Caution Changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment.
Page 47
Revision History ∗ A U-side end plate (for the SY) has been added. Edition B ∗ The EXW1 series compact wireless system has been added. Edition C Safety Instructions Be sure to read the “Handling Precautions for SMC Products” (M-E03-3) and “Operation Manual” before use.