SMC Networks EX140-SMJ1 Series Operation Manual

Si unit for cc-link
Hide thumbs Also See for EX140-SMJ1 Series:

Advertisement

Quick Links

No.EX##-OME0011-G
PRODUCT NAME
SI unit for CC-Link
MODEL / Series / Product Number
EX140-SMJ1 Series

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EX140-SMJ1 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for SMC Networks EX140-SMJ1 Series

  • Page 1 No.EX##-OME0011-G PRODUCT NAME SI unit for CC-Link MODEL / Series / Product Number EX140-SMJ1 Series...
  • Page 2: Table Of Contents

    Table of Contents Safety Instructions Model Indication and How to Order Summary of Product parts Definition and terminology Mounting and Installation Communication wiring Power supply wiring Settings Maintenance Troubleshooting Specifications Specifications Dimensions No.EX##-OME0011-G...
  • Page 3: Safety Instructions

    Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger". They are all important notes for safety and must be followed in addition to International 1) standards (ISO/IEC) and other safety regulations.
  • Page 4 Caution The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.
  • Page 5 Operator This operation manual is intended for those who have knowledge of machinery using pneumatic equipment, and have sufficient knowledge of assembly, operation and maintenance of such equipment. Only those persons are allowed to perform assembly, operation and maintenance. Read and understand this operation manual carefully before assembling, operating or providing maintenance to the product.
  • Page 6 ■NOTE ○Follow the instructions given below when designing, selecting and handling the product. ●The instructions on design and selection (installation, wiring, environment, adjustment, operation, described below must also be followed. maintenance, etc.) Product specifications •When conformity to UL is required, the SI unit should be used with a UL1310 Class 2 power supply. •The SI unit is a UL approved product only if they have a mark on the body.
  • Page 7 Environment •Select the proper type of protection according to the environment of operation. In case of IP20, avoid use in the place where water and oil scatter. •Do not use the product in an environment where corrosive gases or fluids could be splashed. Otherwise damage to the product and malfunction can result.
  • Page 8: Model Indication And How To Order

    Model Indication and How to Order EX140-SMJ 1 Output type 16 outputs, NPN (positive common) / sink Fieldbus CC-Link Summary of Product parts Element Description Communication terminals (DA, DB, DG) To connect the CC-Link line with a CC-Link-dedicated cable. Power supply terminals (24 V, 0 V) To supply power to solenoid valves.
  • Page 9: Mounting And Installation

    Mounting and Installation ■Communication wiring The connection between a CC-Link-dedicated cable and an SI unit communication terminal for CC-Link is shown below. The hole diameter for the screwdriver entry to access the terminal screw is 6 mm. (The terminal screw is an M3 cross head screw.) (1) Be sure to connect each signal line to its dedicated terminal.
  • Page 10 (4) The CC-Link-dedicated cable’s shield wire (SLD) should be connected to the “FG” terminal of the SI unit. For the EX140-SMJ1, the "SLD terminal" and "FG terminal" are common. Therefore, connect 3 wires to the "FG Terminal" as shown in Fig. 4. Fig.
  • Page 11: Power Supply Wiring

    ■Power supply wiring Connect the power supply wiring to the solenoid valve power supply terminals and to the SI unit control power supply terminals. Although the power supply consists of two separate systems, it is possible to use either a single power supply or separate power supplies.
  • Page 12 ○Switch setting The setting for the station number and communication speed can be carried out using the rotary switches under the SI unit cover. The setting for HOLD/CLEAR can be carried out using the DIP switch under the SI unit cover. The settings must be carried out with the power supply for the SI unit turned off.
  • Page 13 ○Output and error information (1) I/O mapping table for master station Buffer Memory. Example when SI unit station is assigned to “01”. Buffer area of master station Example: QJ61BT11N Address Remote output (RY) RY0F to RY00 For station 1 RY1F to RY10 RY2F to RY20 For station 2 RY3F to RY30...
  • Page 14: Maintenance

    Maintenance •Mounting and wiring Item to inspect Criteria Countermeasure Are SI unit terminals Tighten the connector. (for communication and power No looseness. (Refer to “Mounting/Installation”) supply) securely connected? Are the terminating resistors securely Connect suitable terminating resistors to connected to both ends of the Terminating resistors must be cables.
  • Page 15: Troubleshooting

    Troubleshooting ○Troubleshooting Applicable model: EX140-SMJ1 If an operation failure of the product occurs, please confirm the cause of the failure from the following table. If a cause applicable to the failure cannot be identified and normal operation can be recovered by replacement with a new product, this indicates that the product itself was faulty.
  • Page 16 ○Faults and countermeasures Trouble Problem Possible cause Investigation method Countermeasure Check the SI unit control power supply cables for breaks, and check SI unit control that the terminals are not loose. Connect the power supply power supply Avoid repetitive bending and stress cable correctly.
  • Page 17 Trouble Problem Possible cause Investigation method Countermeasure Communication Check that the SI unit communication speed setting speed setting and the setting in the SI unit L RUN error master station are the same. LED is ON Correct the setting. Station number Check that the station number setting error or SD LED is OFF...
  • Page 18: Specifications

    Specifications ■Specifications Model No. EX140-SMJ1 Applicable system CC-Link Ver.1.10 Occupied station 1 station Station number setting 1 to 64 (Set with a rotary switch) range Communication Station type Remote I/O specification Communication speed 156 k/625 k/2.5 M/5 M/10 Mbps Cable length between 20 cm or more stations Max.
  • Page 19: Dimensions

    ■Dimensions -18- No.EX##-OME0011-G...
  • Page 20 Revision history B: New format C: Error correction D: Add the precautions and change into the latest format E: Terminal screw change F: Modified errors in text. (Page 10) G: Limited warranty and Disclaimer are added. Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. ©...