• Unauthorized modifications are made to the display, display cabinet, or the control system. Refer to Daktronics Warranty and Limitation of Liability (p�29) at the end of this manual for the full Daktronics Warranty and Limitation of Liability. Contact Information For assistance before, during, or after display installation, please contact Daktronics Technical Support: 1-800-DAK-TRON (325-8766).
Installation Preparation This section explains what to consider before installing a Daktronics GT6x Small Matrix display. Follow all guidelines and safety precautions in this manual when installing the display. Do not modify the display or control system in any manner without the written permission of Daktronics engineering staff.
Follow all guidelines and safety precautions in this manual when installing the display. Do not modify the display or control system in any manner without the written permission of Daktronics engineering staff. Any unauthorized modifications will nullify the warranty. Display Installation Preparation •...
Install the display according to all applicable local and national electrical codes. This includes proper grounding and bonding of the display. • Do not connect the display to any voltage other than that listed on the Daktronics product label. •...
Conduit Daktronics does not provide conduit. Separate conduit must be used to route: • Power • Signal IN wires to the signal termination enclosure (when applicable) • Signal OUT wires (if not using the provided interconnect cable) For power, displays have either a J-box or a "...
Only qualified individuals may perform electrical work, including verification of ground resistance. Daktronics is not responsible for improper grounding or damage incurred as a result of improper grounding. Grounding methods must meet the provisions of all applicable local and national codes.
Displays With Internal Power Termination To terminate single-phase power Four Breaker Connections to the internal power termination • Black Line Wiring • White Neutral Wiring (Z1 Load to Pin 2 of J41) (Z1 Load to Pin 1 of J41) panel, complete these steps: •...
Signal Cable Installation Primary/Mirror Display Interconnections For data to get from the Primary display to the Mirror display, the interconnect cable must be connected. This cable typically comes attached to the rear of the display. 1� Locate the cable, unpackage it, and remove protective caps from cables.
Network and Communication Installation This section explains how to setup communications with a GT6x Small Matrix series display through a network or an individual computer. Obtain information about the available standard communication options in the provided quick guides and reference manuals. System Startup The display shows a boot sequence shortly after the power is turned on.
It also provides basic information about available standard communication options. Daktronics is not responsible for setting up a customer’s network system neither a Local Area Network (LAN) nor a Wide Area Network (WAN). Keep the following points in mind when installing network and communication: •...
Ethernet DD1417611 DD1417581 Fiber Ethernet DD3486291 Cell Modem These are the standard communication types, but each site is unique and may include additional equipment. If problems arise, contact the display’s service company or Daktronics Customer Service. Network and Communication Installation...
Logging In–Daktronics Web-Hosted Server 1� Navigate to https://venus�daktronics�com. 2� Enter the user name and password provided by Daktronics into the Email and Password text boxes and click Login. Refer to Figure 10. 3� Change the password in the Update Password window.
Venus Menu Overview After initial login, the Dashboard window opens showing status tiles for each display in the system. Click Show Menu at the upper-left corner of the screen to open the main menu. Refer to Figure 11 and the table below. Menu Item Description Shows status tiles for each display and any...
Refer to Figure 13. Support Information If further assistance is required, Daktronics Customer Service is available 7 a.m. to 7 p.m. CST, Monday to Friday via telephone or online connection. Figure 12: Account Information Telephone •...
Display Maintenance This section explains the steps necessary to maintain GT6x Small Matrix displays, which are front accessible only. Remove modules on the front of the display to gain access to internal components. Figure 14 and Figure 18 show internal component locations. •...
5� Disconnect the SATA cables and unplug the power cable by squeezing the tabs on the sides of the plug head and pulling it out. Refer to Figure 16. 6� Reconnect the SATA and power cables to the module. 7� Push the cables into the display so they do not get pinched.
Dry Cleaning Process 1� Turn off power to the display. 2� Rub a dry, soft terry cloth towel horizontally across each row of LEDs. Make four passes per row of LEDs before moving to the next row of LEDs. Work from top to bottom safely within reach from a lift or a stage.
This section provides basic display information such as power and signal routing as well as basic troubleshooting tips for common problems. For issues not addressed in this manual, please contact Daktronics Technical Support. Power and Signal Routing Understanding power and signal flow through the display can help a technician troubleshoot an issue.
Signal Routing Figure 19 shows how signal is routed through the display. Thermostat RJ45 Quick Input Connect Quick Connect Light Detector Fans Figure 19: Signal Routing 1� Signal enters the display from the external signal enclosure through the signal input quick-connect jacks (1).
Refer to Figure 22. Once the cables are connected, cycle power to the PLR and it will boot-up in self-test mode. Following is a table of a few possible messages. Contact Daktronics Technical Support for additional information or questions. Code...
If any Err message is displayed, send the PLR back to Daktronics for repair or replacement. Module Diagnostics Modules are equipped with a status indicator LED that can help troubleshoot possible issues. Under normal operation, the status indicator LED should flash once every four seconds.
If a replacement part cannot be identified, contact Daktronics Customer Service. Figure 24: Typical Parts Label Refer to Section 11: Daktronics Exchange and Repair & Return Programs (p�24) if replacing or repairing any display component. Module Replacement Note: Do not allow modules to hang by the cables.
Controller Power Supply Replacement 1� Remove the modules in front of the controller. 2� Disconnect the power supply from any wiring harnesses connected to it. 3� Push down on the top leg of the wire form bracket and rotate the power supply clockwise. Refer to Figure 26.
In most circumstances, the replacement part will be invoiced at the time it is shipped. If the failed part or replacement part is not returned to Daktronics within 3 weeks of the ship date, Daktronics will assume that the customer is purchasing the replacement part and will send an invoice for the value of the new sale part.
Repair & Return Program For items not subject to exchange, Daktronics offers a Repair & Return Program. To send a part for repair, follow these steps: 1� Call Daktronics Customer Service: • United States & Canada: 1-800-DAK-TRON (325-8766) • Outside the U.S. & Canada: +1-605-275-1040 2�...
Reference Drawings Shop drawings show display dimensions, signal and power connection locations, as well as information on service access and power requirements. To obtain copies of shop drawings or other reference drawings specific to your display, contact Daktronics Customer Service: •...
Page 32
Daktronics Warranty and Limitation of Liability...
Daktronics Warranty and Limitation of Liability This section includes the Daktronics Warranty & Limitation of Liability statement (SL-02374). Daktronics Warranty and Limitation of Liability...