48
107P2 CM 25 GSIII
Go to cover page
1.0
2.0
2.1
3.0
3.1
3.1.1 Input requirements
A. Input signals
00-06-07
K.C. Huang
Back
GENERAL PRODUCT SPECIFICATION
Introduction
This document is related to the 17" AUTOSCAN color monitor
and max. resolution:
1920 X 1440 by 60Hz refresh rate
General description
This AUTOSCAN analog colour monitor is specified as a
display peripheral within an IBM compatible PC.
The AUTOSCAN analog colour monitor is to operate at
H: 30 to 92.0 KHz V: 50 to 160 Hz
can be applied to all RGB analog computers within this scanning frequencies.
The AUTOSCAN analog colour monitor is intended to be a
finished product, basically a display device mounted inside
a plastic enclosure which provides the aesthetic, mechanical,
ergonomic and safety requirements.
General condition
The unit will produce a usable image after switching -on,
measurements are to be carried out with a full stabilized
set after about 30 minutes warm -up at room ambient
temperature of 25 °C.
Repetitive power on/off cycles are allowed though should
be avoided within 4 sec.
Electrical characteristics
Signal interface
This AUTOSCAN analog colour display has an analog video
interface to operates at a multi -frequencies timing in
several display modes.
Video - 0.7 Vp-p 75 ohms (for individual of R,G and B
signals must not deviate 0.015 Vp -p from each
other for balance of white pattern)
Sync - TTL level
(between 0 and 0.6 V to be considered as low
level, between 2.3 and 5.0 V as high level)
B. Impedance
Video - Terminated with 75 ohms
Sync - Terminated with 4.7K ohms pull -down resistors.
CM25-17" 107P2 92KHz AR CRT
TYPE
: 107P20/00H
BRAND : PHILIPS
00-06-07
8639 000 10649
590
4
23
Forward