  • Page 1 AC Ammeter DCP-96 Aac INSTRUCTION MANUAL (M264B01-03-22A)
  • Page 2 DCP-96 Aac Instruction Manual...
  • Page 3: Safety Precautions

    CIRCUTOR, SA reserves the right to make modifications to the device or the unit specifications set out in this instruction manual without prior notice. CIRCUTOR, SA on its web site, supplies its customers with the latest versions of the device specifica- tions and the most updated manuals.
  • Page 4: Table Of Contents

    DCP-96 Aac CONTENTS SAFETY PRECAUTIONS ���������������������������������������������������������������������������������������������������������������������������������������������������������3 DISCLAIMER ��������������������������������������������������������������������������������������������������������������������������������������������������������������������������3 CONTENTS �����������������������������������������������������������������������������������������������������������������������������������������������������������������������������4 REVISION LOG �����������������������������������������������������������������������������������������������������������������������������������������������������������������������5 SYMBOLS �������������������������������������������������������������������������������������������������������������������������������������������������������������������������������5 1�- VERIFICATION UPON RECEPTION ������������������������������������������������������������������������������������������������������������������������������������6 2�- PRODUCT DESCRIPTION �������������������������������������������������������������������������������������������������������������������������������������������������6 3�- DEVICE INSTALLATION ���������������������������������������������������������������������������������������������������������������������������������������������������� 7 3�1�- PRIOR RECOMMENDATIONS ������������������������������������������������������������������������������������������������������������������������������������ 7 3�2�- INSTALLATION ���������������������������������������������������������������������������������������������������������������������������������������������������������8 3�3�- DEVICE TERMINALS �������������������������������������������������������������������������������������������������������������������������������������������������9 3�4�-CONNECTION DIAGRAM �����������������������������������������������������������������������������������������������������������������������������������������...
  • Page 5: Revision Log

    DCP-96 Aac REVISION LOG Table 1: Revision log Date Revision Description 11/19 M264B01-03-19A First Version Change in the following sections: 04/21 M264B01-03-21A Change in the following sections: 02/22 M264B01-03-22A 4.1. SYMBOLS Table 2:Symbols� Symbol Description In accordance with the relevant European directive.
  • Page 6: 1�- Verification Upon Reception

    If any problem is noticed upon reception, immediately contact the transport com- pany and/or CIRCUTOR’s after-sales service 2.- PRODUCT DESCRIPTION The DCP-96 Aac is a device designed to measure and display the current and the frequency AC three- phase. The device features:...
  • Page 7: 3�- Device Installation

    The DCP-96 Aac device must be installed by authorised and qualified staff. The power supply plug must be disconnected and measurement systems switched off before handling, altering the connections or replacing the device.
  • Page 8: 3�2�- Installation

    DCP-96 Aac 3�2�- INSTALLATION Terminals, opening covers or removing elements can expose parts that are hazard- ous to the touch while the device is powered. Do not use the device until it is fully installed. The device should be installed inside an electric panel or enclosure, and panel-mounted.
  • Page 9: 3�3�- Device Terminals

    An incorrect type of con- nection or an error in phase sequence may cause measurement errors. 3�3�- DEVICE TERMINALS Table 4: List of DCP-96 Aac terminals� Device terminals 1: L/+, Power supply...
  • Page 10: 3�4�-Connection Diagram

    DCP-96 Aac 3�4�-CONNECTION DIAGRAM Alimentación Auxiliar Power Supply S2 S1 S2 S1 CARGA / LOAD Figure 5: Current measurement� Instruction Manual...
  • Page 11: 4�- Operation

    Icon Description Configuration screen 4-wire connection error. 4�2�- KEYBOARD FUNCTIONS The DCP-96 Aac has 3 keys that allow you to browse through and program the device, Table 6 Table 7  Display screens: Table 6: Keyboard function: Display screens� Keystroke Previous screen.
  • Page 12 DCP-96 Aac  Configuration screens: Table 7: Keyboard function: Configuration screens� Keystroke Browses through the different menu screens. Browses through the different options. Browses through the different menu screens. Browses through the different options. Skips to the next configuration menu.
  • Page 13: 5�- Display

    DCP-96 Aac 5.- DISPLAY 5�1�- SINGLE-PHASE NETWORK MEASURING The DCP-96 Aac has 2 display screens in the single-phase network measurement system, see “6.1.1.- MEASUREMENT SYSTEM”, Table 8 Use the keys to browse through the different screens. The display screens can change automatically depending on the time programmed in the section ”.
  • Page 14: 5�2�- Three-Phase Network Measure With 3 Or 4 Wire

    DCP-96 Aac 5�2�- THREE-PHASE NETWORK MEASURE WITH 3 OR 4 WIRE The DCP-96 Aac has 2 display screens in the three-phase network measurement system with a 3 or 4 wire connection, see “6.1.1.- MEASUREMENT SYSTEM”, Table 8 Use the keys to browse through the different screens.
  • Page 15: 6�- Configuration

    1002 Software version 1906 Figure 7: DCP-96 Aac configuration menu� From any screen of the configuration menus, if no key is pressed for 1 minute, the device leaves the configuration menu and returns to the display screen. Note: In you can see the complete configuration menu.
  • Page 16: 6�1�- Configuration Of The Input

    DCP-96 Aac Note: The password can be modified, see � “6.2.4.- ACCESS PASSWORD” With a long keystroke (>3s), press to validate the data. If the password entered is incorrect, the message will appear for a few seconds and the device...
  • Page 17: 6�1�2�- Primary Current

    DCP-96 Aac 6�1�2�- PRIMARY CURRENT This screen is used to configure the value of the primary current. inpt inpt >3s Ct 1 Ct 1 0005 0005 With a long keystroke (>3s), press to access the value’s configuration. Use the key to modify the value of the flashing digit.
  • Page 18: 6�1�4�- Save Configuration

    DCP-96 Aac 6�1�4�- SAVE CONFIGURATION This screen is used to save the device’s configuration. SAuE SAuE >3s With a long keystroke (>3s), press to access the value’s configuration. Use the keys to browse through the different options: , to not save the configuration.
  • Page 19: 6�2�- System Configuration

    DCP-96 Aac 6�2�- SYSTEM CONFIGURATION , shows the system configuration menu. Figure 10 >3s Cyclic display >3s liGH LiGH Display backlight 0000 0000 >3s diSP diSp Initial display screen >3s CodE CodE Access password 0001 0001 >3s Light alarm SAuE SAuE >3s...
  • Page 20: 6�2�2�- Display Backlight

    DCP-96 Aac 6�2�2�- DISPLAY BACKLIGHT The time that the display backlight will stay lit in seconds if no key is pressed is programmed on this screen. >3s liGH LiGH 0000 0000 With a long keystroke (>3s), press to access the value’s configuration.
  • Page 21: 6�2�4�- Access Password

    DCP-96 Aac 6�2�4�- ACCESS PASSWORD This screen is used to configure the value of the password used to access the configuration menu. >3s CodE CodE 0001 0001 With a long keystroke (>3s), press to access the value’s configuration. When the desired value is shown on the screen, press the keys to skip the digit.
  • Page 22: 6�2�6�- Save Configuration

    DCP-96 Aac 6�2�6�- SAVE CONFIGURATION This screen is used to save the device’s configuration. SAuE SAuE >3s With a long keystroke (>3s), press to access the value’s configuration. Use the keys to browse through the different options: , to not save the configuration.
  • Page 23: 7�- Technical Features

    DCP-96 Aac 7.- TECHNICAL FEATURES AC Power supply Rated voltage 80 ... 270 V ~ Frequency 50 / 60 Hz Consumption 1 ... 4 VA Installation category CAT III 300V DC Power supply Rated voltage 80 ... 270 V 18 ... 36 V Consumption 0.5 ...0.7 W...
  • Page 24 Electromagnetic compatibility (EMC) Part 4-11: Testing and measurement techniques� IEC 61000-4-11 Voltage dips, short interruptions and voltage variations immunity tests Safety requirements for electrical equipment for measurement, control and laboratory IEC 61010-1 use� Part 1: General requirements� 4(max) 41.5 Figure 11: Dimensions of the DCP-96 Aac� Instruction Manual...
  • Page 25: 8�- Maintenance And Technical Service

    DCP-96 Aac 8.- MAINTENANCE AND TECHNICAL SERVICE In the case of any query in relation to device operation or malfunction, please contact the CIRCUTOR, SA Technical Support Service. Technical Assistance Service Vial Sant Jordi, s/n, 08232 - Viladecavalls (Barcelona) Tel: 902 449 459 ( España) / +34 937 452 919 (outside of Spain) email: sat@circutor.com...
  • Page 26: 10�- Ce Certificate

    DCP-96 Aac 10.- CE CERTIFICATE Instruction Manual...
  • Page 27 DCP-96 Aac Instruction Manual...
  • Page 28 DCP-96 Aac Instruction Manual...
  • Page 29: Annex A.- Configuration Menu

    DCP-96 Aac ANNEX A.- CONFIGURATION MENU ProG CodE CodE 2206 >3s >3s 2207 0000 0001 2208 >3s inpt inpt inpt inpt >3s Measurement system >3s inpt inpt >3s Ct 1 Primary current Ct 1 0005 0005 inpt inpt >3s Ct 2...
  • Page 30 CIRCUTOR, SA Vial Sant Jordi, s/n 08232 - Viladecavalls (Barcelona) Tel: (+34) 93 745 29 00 - Fax: (+34) 93 745 29 14 www.circutor.es central@circutor.com...