Error Messages Of The Mxa Interface In The Submit Interpreter - Kuka .PLC mxAutomation Logix 1.0 Manual

Table of Contents

Advertisement

No.
Message text
65
INVALID REAL
VALUE
66
ERROR SETTING
OUTPUT
67
ERROR SETTING
SOFTEND
8.2

Error messages of the mxA interface in the Submit interpreter

No.
Message text
401
INTERNAL ERROR
402
ASSERT FAILED
403
INVALID COM-
MAND ID
404
INVALID COM-
MAND STATE
405
OVERFLOW COM-
MAND QUEUE
406
INVALID COM-
MAND QUEUE
INDEX
407
INVALID COM-
MAND (PRE)
QUEUE INDEX
408
INVALID
WRITE_Q_IDX
AND
WRITE_PRE_Q_ID
X
409
OVERFLOW STA-
TUS RETURN
QUEUE (SUBMIT)
410
INVALID FIELD-
BUS TELEGRAMM
LENGTH
Issued: 13.08.2012 Version: KST PLC mxAutomation Logix 1.0 V1 en (PDF)
Cause
The programmed Real value is
invalid.
Error writing a digital output.
The output may already be
assigned by the system.
Error writing the software limit
switches: one possible error, for
example, is writing a rotational
axis with a value outside the
range +/-360°.
Cause
Internal exceptional error
Internal exceptional error
Internal exceptional error
Internal exceptional error
Internal exceptional error
Internal exceptional error
Internal exceptional error
Internal exceptional error
There are more than 100
checkback signals relating to
status changes waiting to be
transferred from the robot con-
troller to the PLC.
The transmission rate is consid-
erably lower than the process-
ing speed.
Internal exceptional error
8 Messages
Remedy
Program a valid value:
-2,147,483,500 ...
+2,147,483,500
Use a different digital output
(parameter Number):
1 ... 2,048
Program valid values for the
software limit switches (see
machine data).
Remedy
Contact KUKA Roboter GmbH.
(>>>
9 "KUKA Service"
Page 111)
Reduce the number of state-
ments to be buffered simultane-
ously.
If this is not possible, contact
KUKA Roboter GmbH.
(>>>
9 "KUKA Service"
Page 111)
Contact KUKA Roboter GmbH.
(>>>
9 "KUKA Service"
Page 111)
103 / 123

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KUKA.PLC mxAutomation Logix 1.0 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Related Products for Kuka KUKA.PLC mxAutomation Logix 1.0

Table of Contents

Save PDF