Before switching on the vacuum cleaner make sure all filters are functioning, dry
and placed correctly. Make sure all opening are not blocked. A blockage may
damage the device.

Dust Container

1. To remove the dust container first press the
releasing button (4). Hold the dust container
at by the handle (5) while removing.
2. Firmly hold the bottom part of the dust
container and turn the upper part counter
clockwise to open the container (see picture).
3. To remove the HEPA filter (accessory A) first
turn counter clockwise and pull out. To
reinsert into the container, turn the HEPA filter in clockwise direction.
Motor Pre-Filter
When removing the dust container you will find at the
bottom of the suction opening the small, round pre-filter
(accessory H).
Motor Exhaust Filter
Behind the motor filter cover (8) you will find the motor
exhaust filter (accessory G). To remove the cover, press
down the protruding clip on the cover and pull out the
cover from the device.
To reinsert the cover, grasp the protruding clip and press
down the cover on the housing of the vacuum cleaner.
Than push the cover downwards and back to the housing.
Make sure the cover locks in place and is flush with the
housing.