Татьяна
February 14, 2025

Не поступает вода в гидробак.

User image 67af1bfae6ff0
1 comments:
Mr. Anderson
February 14, 2025

Water may not be entering the Coelbo SWITCHMATIC 1 hydro tank due to the following reasons:

1. Incorrect Pressure Settings: The cut-in (Pstart) and cut-out (Pstop) pressures might not be properly configured, preventing the pump from activating.
2. False Water Shortage Detection: If the required flow is excessive, the SWITCHMATIC 1 may misinterpret it as a lack of water, stopping the system.
3. Improper Installation: The unit must be correctly threaded to a G1/4” male fitting at the pump’s outlet and ensure the hydraulic system is properly installed.
4. Electrical Issues: Incorrect wiring or failure in the power supply could prevent the pump from operating.
5. Auxiliary Control Activation: If an auxiliary element (SW) is installed for pressure control on the suction side and the suction pressure does not reach Pstart, the system will not activate.
6. Delay Settings: A delay setting between 0-9 seconds may be preventing immediate operation.

Checking these factors can help diagnose and resolve the issue.

This answer is automatically generated

Summary of Contents for Coelbo SWITCHMATIC 1

  • Page 1 SWITCHMATIC 1 / 1 plus SWITCHMATIC 2 / 2 plus SWITCHMATIC 3 / 3 plus PROGRAMMATION AVANCÉE Risque de dommage au groupe de pression et/ou à l´installation. Risque de choc électrique. Risque pour les objets et/ou les persones.
  • Page 2: Caractéristiques Techniques

    Pour l’installation électrique, il est essentiel d’utiliser un interrupteur En plus d’avoir toutes les caractéristiques du SWITCHMATIC 1, le différentiel à haute sensibilité: I = Δn 30 mA (classe A ou AC). Il est es- dispositif SWITCHMATIC 2 comprend la lecture instantanée du cou- sentiel d’utiliser un disjoncteur magnéto thermique ajusté...
  • Page 3 En passant de rS0 à rS1 et en appuyant sur ENTER les réglages d’usine sont restaurés. Remarque 2 : Le SWITCHMATIC 1/3 de base peut uniquement détecter l’absence d’eau par la pression minimale de travail. Cela sig- nifie que l’installateur doit déterminer la colonne d’eau de l’installation, la pression fournie par le dispositif de pompa-...
  • Page 4 Remarque 2 : 10. MENU DE PROGRAMMATION AVANCÉ Le SWITCHMATIC 1/3 de base peut uniquement détecter - Appuyez sur pendant 5 secondes. l’absence d’eau par la pression minimale de travail. Cela sig- - Les valeurs se modifient à l’aide des touches nifie que l’installateur doit déterminer la colonne d’eau de...
  • Page 5 0-999 2014/35/EU, 2014/30/EU et 2011/65/EU+2015/863/EU. APM xxx Nombre d’alarmes de surpres- 0-999 Nom: - SWITCHMATIC 1 / 1+ sion (---). - SWITCHMATIC 2 / 2+ - SWITCHMATIC 3 / 3+ rPM x.x Pression maximale enregistrée. Normes : EN-60730-2-6, EN-60730-1, EN-61000-6-1, EN-61000-6- ENTER ->...
  • Page 6 ~1x48-230Vac/Vdc...
  • Page 7 SCHÉMA B : ALIMENTATION ÉLECTRIQUE ET MOTEUR ~1x48÷230Vac/Vdc (SW3) ~1x110÷230Vac (SW1/2) C1 C2 (+) (-) SW1-2 30mA SW1/2 C1 C2 SCHÉMA C: CIRCUIT AUXILIAIRE IN-OUT CLASSEMENT DES CONTACTS Tension de commutation maximale: 230VAC / 220VDC Puissance de commutation maximale: 62,5VA / 30W TENSION MAXIMALE Câbles: max.
  • Page 8 DIAGRAMME D SWITCHMATIC 1 / 3 SWITCHMATIC 2 SWITCHMATIC 1 / 2 SWITCHMATIC 2 / 3 in-out G1/4"F G1/4"f (NPT 1/4" F) (NPT 1/4" f) V14_06/2022...
  • Page 9: Configurazione Avanzata

    SWITCHMATIC 1 / 1 plus SWITCHMATIC 2 / 2 plus SWITCHMATIC 3 / 3 plus CONFIGURAZIONE AVANZATA Rischio di danno al gruppo di pressione o all´impianto. Rischio di scossa elettricha. Rischio per le persone e/o per gli oggetti.
  • Page 10 SWITCHMATIC verificare che l’impianto 2. DESCRIZIONE (diagramma A) idraulico stia montato correttamente, sopratutto che il serbatoio Il SWITCHMATIC 1 è un pressostato elettronico con manometro idropneumatico sia pressurizzato. digitale integrato. Permette di gestire l’avviamento e l’arresto di una pompa monofase di fino a 2,2 kW (3 HP) (SW1-2).
  • Page 11 9. MENU DI PROGRAMMAZIONE BASE PULSANTI PERMU- AZIONE (diagramma C) Da stato ON: dispositivo OFF. - Premere per 5 secondi. Da stato OFF: il dispositivo si mette in - Mediante i tasti si modiffcano i valori. click! marcia e si attiva la pompa fino Pstop. Da qualsiasi dei modi di configurazione: - Premere per confermare e passare al successivo.
  • Page 12 Nota 2: 10. MENU DI PROGRAMMAZIONE AVANZATO SWITCHMATIC 1/3 di base solo può rilevare la mancan- Premere per 5 secondi. za d’acqua per pressione minima di lavoro. Ciò significa - Mediante i tasti si modificano i valori. che l’installatore deve determinare la colonna d’acqua...
  • Page 13: Dichiarazione Di Conformità Ce

    GUASTO A11 xxx Numero di allarmi A11. 0-999 DICHIARAZIONE DI CONFORMITÀ CE COELBO CONTROL SYSTEM, S.L. Dichiaramo, sotto la nostra res- APM xxx Numero di allarmi di sovrapres- 0-999 ponsabilità, che i materiali qui sotto sono conforme alle disposi- sione (---).
  • Page 14 DIAGRAMMA A INDIVIDUALE SWITCHMATIC 1/2 SWITCHMATIC 3 ~1x48-230Vac/Vdc GRUPPO (SOLO SW2)
  • Page 15 SCHEMA B: ALIMENTAZIONE E MOTORE ~1x48÷230Vac/Vdc (SW3) ~1x110÷230Vac (SW1/2) C1 C2 (+) (-) SW1-2 30mA SW1/2 C1 C2 SCHEMA C: CIRCUITO AUSILIARIO IN-OUT CONTATTI RATING Mass. tensione di commutazione:: 230VAC / 220 VDC Mass. potenza di commutazione: 62,5VA / 30W MASS TENSIONE Cavi: max.
  • Page 16 DIAGRAMMA D SWITCHMATIC 1 / 3 SWITCHMATIC 2 DIMENSIONI SWITCHMATIC 1 / 2 SWITCHMATIC 2 / 3 in-out G1/4"F G1/4"f (NPT 1/4" F) (NPT 1/4" f) V14_06/2022...
  • Page 17: Ajustes Avanzados

    SWITCHMATIC 1 / 1 plus SWITCHMATIC 2 / 2 plus SWITCHMATIC 3 / 3 plus AJUSTES AVANZADOS Riesgo de daño al grupo de presión o a la instalación Riesgo por choque eléctrico. Riesgo para personas y/o objetos.
  • Page 18 La unidad SWITCHMATIC 2 además de todas las características del lidad: I = Δn 30 mA (clase A o AC). Es imprescindible utilizar un SWITCHMATIC 1 incluye la lectura de corriente consumida instan- magnetotérmico ajustado al consumo del motor. tánea. Este sistema patentado controla y gestiona la sobreinten- Si ha adquirido la versión sin cables seguir las indicaciones del...
  • Page 19 9. MENÚ DE PROGRAMACIÓN BÁSICO (diagrama C) PULSA- PULSA- ACCIÓN DORES - Pulsar durante 5 segundos. CIÓN - Mediante las teclas se modificarán los valores. Desde estado ON: dispositivo OFF. - Pulsar para validar y pasar al siguiente. Desde estado OFF: el dispositivo se pone en marcha y se activa la bomba - La secuencia de parámetros es la siguiente: click!
  • Page 20 Al pasar de rS0 a rS1 y pulsar ENTER se restablecen los parámetros de fábrica. Nota 2: El SWITCHMATIC 1/3 sólo puede detectar la falta de agua por presión mínima de trabajo. Esto significa que el instala- dor debe determinar la columna de agua de la instalación, la...
  • Page 21 15. DECLARACIÓN DE CONFORMIDAD CE A01 xxx Número de alarmas A01. 0-999 COELBO CONTROL SYSTEM, S.L. Declaramos, bajo nuestra res- ponsabilidad, que los materiales designados en la presente, están A02 xxx Número de alarmas A02. 0-999 conforme a las disposiciones de las siguientes Directivas Europeas: A04 xxx Número de alarmas A04.
  • Page 22 DIAGRAMA A INDIVIDUAL SWITCHMATIC 1/2 SWITCHMATIC 3 ~1x48-230Vac/Vdc GRUPAL (SÓLO SW2) USO OBLIGATORIO DE TANQUE HIDRONEUMÁTICO...
  • Page 23 DIAGRAMA B: ALIMENTACIÓN Y MOTOR ~1x48÷230Vac/Vdc (SW3) ~1x110÷230Vac (SW1/2) C1 C2 (+) (-) SW1-2 30mA SW1/2 C1 C2 DIAGRAMA C: CIRCUITO AUXILIAR IN-OUT CLASIFICACIÓN DE CONTACTOS Max. Voltaje de conmutación: 230VAC / 220VDC Max. potencia de conmutación: 62,5VA / 30W VOLTAJE MÁXIMO Cables: max.
  • Page 24 DIAGRAMA D SWITCHMATIC 1 / 3 SWITCHMATIC 2 DIMENSIONES SWITCHMATIC 1 / 2 SWITCHMATIC 2 / 3 in-out G1/4"F G1/4"f (NPT 1/4" F) (NPT 1/4" f) V14_06/2022...
  • Page 25: Advanced Settings

    SWITCHMATIC 1 / 1 plus SWITCHMATIC 2 / 2 plus SWITCHMATIC 3 / 3 plus ADVANCED SETTINGS Risk of damaging the pressure assemblies and/or the plant. Risk by electric shock. Risk for people and/or objects.
  • Page 26: Technical Characteristics

    2. DESCRIPTION (diagram A) is pressurized. SWITCHMATIC 1 is an electronic pressure switch with integrated digital manometer. It manages the start and stop of a single-pha- 6. ELECTRIC CONNECTION (diagram B) se pump up to 2.2kW (3 HP) (SW1-2).
  • Page 27: Basic Menu

    P-BUT- 9. BASIC MENU (diagram C) TOUCH ACTION - Press simultaneously during 5 seconds. From state ON: unit OFF. - By mean of the values can be changed. From state OFF: the pump starts and - Press for validation. click! keeps operating until reaching Pstop.
  • Page 28: Advanced Menu

    TING pressure because the flow requirement is excessive. In this Select the operation MODE as a con- case SWITCHMATIC 1/3 would activate a false dry-running ventional pressure switch (nc = norma- alarm. lly closed) or reverse (no = normally If these concepts are not clear, it is preferable not configure open).
  • Page 29: Warnings And Alarms

    0-999 15. EC STAMENT OF COMPLIANCE A11 xxx Number of A11 alarms. 0-999 COELBO CONTROL SYSTEM, S.L. States, on our own responsibi- lity, that all materials here with related comply with the following APM xxx Number of over-pressure 0-999 European Directives: alarms (---).
  • Page 30 DIAGRAM A INDIVIDUAL SWITCHMATIC 1/2 SWITCHMATIC 3 MANDATORY USE MANDATORY USE OF PRESSURE TANK OF PRESSURE TANK ~1x48-230Vac/Vdc SYSTEM (ONLY SW2) MANDATORY USE OF PRESSURE TANK...
  • Page 31 DIAGRAM B: POWER SUPPLY AND MOTOR ~1x48÷230Vac/Vdc (SW3) ~1x110÷230Vac (SW1/2) C1 C2 (+) (-) SW1-2 30mA SW1/2 C1 C2 DIAGRAM C: AUXILIARY CIRCUIT IN-OUT CONTACTS RATING Max. switching voltage: 230VAC / 220 VDC Max. switching power: 62,5VA / 30W MAX VOLTAGE Cables: max.
  • Page 32 DIAGRAM D SWITCHMATIC 1 / 3 SWITCHMATIC 2 DIMENSIONS SWITCHMATIC 1 / 2 SWITCHMATIC 2 / 3 in-out G1/4"F G1/4"f (NPT 1/4" F) (NPT 1/4" f) V14_06/2022...

Table of Contents