Coelbo SWITCHMATIC 1 Advanced Settings

Coelbo SWITCHMATIC 1 Advanced Settings

Hide thumbs Also See for SWITCHMATIC 1:

Advertisement

SWITCHMATIC 1 / 1 plus
SWITCHMATIC 2 / 2 plus
SWITCHMATIC 3
ADVANCED SETTINGS
Risk of damaging the pressure assemblies and/or the plant.
Risk by electric shock.
Risk for people and/or objects.
/ 3 plus
1
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SWITCHMATIC 1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Coelbo SWITCHMATIC 1

  • Page 1 SWITCHMATIC 1 / 1 plus SWITCHMATIC 2 / 2 plus SWITCHMATIC 3 / 3 plus ADVANCED SETTINGS Risk of damaging the pressure assemblies and/or the plant. Risk by electric shock. Risk for people and/or objects.
  • Page 2: Technical Characteristics

    2. DESCRIPTION (diagram A) is pressurized. SWITCHMATIC 1 is an electronic pressure switch with integrated digital manometer. It manages the start and stop of a single-pha- 6. ELECTRIC CONNECTION (diagram B) se pump up to 2.2kW (3 HP) (SW1-2).
  • Page 3: Basic Menu

    P-BUT- 9. BASIC MENU (diagram C) TOUCH ACTION - Press simultaneously during 5 seconds. From state ON: unit OFF. - By mean of the values can be changed. From state OFF: the pump starts and - Press for validation. click! keeps operating until reaching Pstop.
  • Page 4: Advanced Menu

    SYSTEM REACTION SET- pressure because the ow requirement is excessive. In this TING case SWITCHMATIC 1/3 would activate a alse dry-running Select the operation MODE as a con- alarm. ventional pressure switch (nc = norma- I these concepts are not clear, it is preerable not congure...
  • Page 5: Warnings And Alarms

    0-999 15. EC STAMENT OF COMPLIANCE A11 xxx Number of A11 alarms. 0-999 COELBO CONTROL SYSTEM, S.L. States, on our own responsibi- lity, that all materials here with related comply with the following APM xxx Number of over-pressure 0-999 European Directives: alarms (---).
  • Page 6 DIAGRAM A INDIVIDUAL SWITCHMATIC 1/2 SWITCHMATIC 3 MANDATORY USE MANDATORY USE OF PRESSURE TANK OF PRESSURE TANK ~1x48-230Vac/Vdc SYSTEM (ONLY SW2) MANDATORY USE OF PRESSURE TANK...
  • Page 7 DIAGRAM B: POWER SUPPLY AND MOTOR ~1x48÷230Vac/Vdc (SW3) ~1x110÷230Vac (SW1/2) C1 C2 (+) (-) SW1-2 30mA SW1/2 C1 C2 DIAGRAM C: AUXILIARY CIRCUIT IN-OUT CONTACTS RATING Max. switching voltage: 230VAC / 220 VDC Max. switching power: 62,5VA / 30W MAX VOLTAGE Cables: max.
  • Page 8 DIAGRAM D SWITCHMATIC 1 / 3 SWITCHMATIC 2 DIMENSIONS SWITCHMATIC 1 / 2 SWITCHMATIC 2 / 3 in-out G1/4"F G1/4"f (NPT 1/4" F) (NPT 1/4" f) V14_07/2022...

Table of Contents