Mounting Dimensions; Mounting The Device; Mounting In Contact With The Process - Endress+Hauser Solimotion FTR16 Operating Instructions Manual

Flow indicator for bulk solids
Hide thumbs Also See for Solimotion FTR16:
Table of Contents

Advertisement

Solimotion FTR16
Endress+Hauser
5�1�3

Mounting dimensions

90 (3.54)
20 (0.79)
110 (4.33)
28 (1.10)
4
Mounting dimensions. Unit of measurement mm (in)
5�2

Mounting the device

5�2�1

Mounting in contact with the process

The FTR16 is screwed directly into the process (for example existing threads or vessel
sleeves) with its process connection (standard threads G 1 and G 1½ according to ISO
228-1 or 1½ NPT according to ANSI/ASME B1.20.1).
Direct mounting with threaded connection
The simplest mounting method is by screwing into the process wall. To do this, a corre-
sponding internal thread (G 1, G 1½ or 1½ NPT) must be available in the process.
5
Mounting with threaded connection
• If the process connection is not screwed far enough into the process wall, there is a risk
that material will accumulate in front of the device (A), thereby damping the microwave
signal.
• If, on the other hand, the process connection is screwed too far into the process (B),
there is a risk of damage occurring as a result of large product items falling.
110 (4.33)
40 (1.57)
70
(2.76)
A
Mounting
55 (2.17)
0000000012
B
0000000020
9

Advertisement

Table of Contents
loading

Table of Contents