Installation Of The Weather Compensated Controller Pwr6 - PAW HeatBloC K34R Installation And Operating Instructions Manual

Hide thumbs Also See for HeatBloC K34R:
Table of Contents

Advertisement

3.5
Installation of the weather
compensated controller PWR6
Fig. 1
Fig. 2
Fig. 3
16
for mixing valve with flow on the right:
Stop bolts
safety plug
993x0663Mx-mub-en – V01
1. Turn the rotary knob
of the mixing valve into position "5".
2. When the weather compensated controller
is delivered, it is in centre position.
By disengaging the gear (●push○), you can
adjust the controller at the rotary knob. In
this way, you can test if the actuator / rotary
knob is mounted correctly.
3. Mount the stop bolts, if necessary.
4. Push the weather compensated controller
PWR6 on the rotary knob of the mixing
valve and mount it onto the two stop bolts
(fig. 1).
The weather compensated controller must
be mounted according to figure 2.
5. Re-engage the gear (●push○).
6. Set the controller to automatic operation
mode.
7. Mount the flow contact sensor, the external
sensor and the source sensor (immersion
sensor). Connect these with the controller.
8. If a room control unit is available, it also
must be connected to the controller via a
bus line).
9. After the mounting is completed, the safety
plug can be plugged into a corresponding
socket (fig. 3).
10. For the commissioning, please observe the
instructions of the controller.