Transformer
Descriptions
Input voltage
Output voltage
Class
Power
DPS Switch
Descriptions
Power max.
Electrical configuration
Suggested Wiring
Gap distance max.

Operation at a glance

When the outside WAVE TO OPEN touchless switch is activated it will trigger its N.O. relay contact to send a momentary
closure to the restroom kit allowing the door to swing open. When the interior WAVE TO LOCK touchless switch is
activated it will trigger its N.O. relay contact to send a momentary closure to the restroom kit to lock the Restroom and
switch the light rings color from green to red. The inside WAVE TO OPEN, when activated, will unlock the door and the door
will swing open. The restroom can also be unlocked by opening the door from the inside which will break the door contact
circuit causing the restroom kit to reset and unlock the door. The light rings will switch back to green, indicating that the
restroom is now vacant.

Installation

1
Mounting
L IMPORTANT: Do not apply power to the unit until you have fully read the instructions and have made the required
adjustments!
The touchless actuators may be mounted in conventional plastic electrical gang boxes. Ensure that the unit sensor does
not come in contact with any metal components within the gang box to avoid damaging the unit. Do not place the sensor
in the door's opening range, where the sensor may see door movement. Do not place moving objects in front of the sensor.
Always use the given foam gasket. For the installation of electrical gang boxes from other manufacturers, refer to the
mounting box instructions that come with the product.
Actuators
The touchless actuators may be mounted in single gang or double gang electrical boxes, and 4 x 4 boxes.
L NOTE: Actuators are for interior use only!
Single/double gang mount box
L Note: Electrical boxes for all installations are needed, but not included. For the electrical box installation, refer to
the mounting box instructions that come with the product.
1a If using an in-wall box ensure the box is square and flush with the wall surface. If using a surface box, ensure it is secure
and flush. If using a 4 x 4 box, ensure the box is square and flush with the wall surface, then attach the metal adaptor
plate (included in the packages) to the box using appropriate fasteners.
1b Bring your 4 or 6-conductor wire through the back or side of the enclosure and leave approximately 6" tail for wiring
connection.
1c Make the electrical connections to the device according to the wiring section.
1d Using the dip switch located on the end of the unit, set the operating mode.
1e Attach the unit to the enclosure using the two #6-32 screws provided.
1f
Apply power and adjust range and time delay via the potentiometers on the front of the unit.
1g Attach the faceplate to the unit using the two black #6-32 x 1/2'' machine screws or tamperproof screws.
1h Apply the label as required.
L Note: Do not overtighten screws!
8310-2410 Series
120V AC
24V AC @ 60 Hz
B2
50 VA
8310-2420 Series
3.0 W
SPDT
22AWG
0.75"